During the warranty period, the following situations are not covered by the warranty
- Improper use leads to human damage
- Damage due to improper transportation after-sale
- Damage caused by failure to use the original accessories of the company as required Any self-modified, disassembled, and repaired product
- Replacement of worn parts
- Any natural wear
Common problems
- After the receiving switch is turned on, the blister backlight will flash, which is a working signal indicating that it is in the receiving state, which is a normal phenomenon;
- The laser line flashes to prove that the machine is not in the setting range, please adjust the level through the legs;
- The laser line appears blurred. Please wipe the outer glass with a clean cotton cloth.
Attention
- nonprofessionals, do not disassemble the machine;
- please avoid severe vibration, collision, and falling of the machine;
- please pay attention to locking the locking switch after use;
- do not leave the battery in the machine to avoid leakage of battery liquid;
- do not look directly at the laser line. It should be used with protective glasses;
- do not wipe the instrument with organic solvent.
Certificate
- Name:
- Model:
- No.:
- Examiner:
- Date:
User save a copy (please save this part properly)
Warranty Card The user must present a copy of the card and an official invoice
at the time of warranty to confirm your warranty. service.
Receipt (please fill it in and send it back)
To ensure that you can enjoy the above warranty service, please fill in all
forms and send the “receipt” back to our company within 7 days, which will
take effect on the date of receiving the receipt!
Instrument specifications
Laser ray | 360° X 3 12 lines (30) |
---|---|
360° X 4 16 lines (40) | |
Laser ray | Wavelength 650nm, red light |
Wavelength 515nm, blue light | |
Wavelength 532nm, green light |
Horizontal / vertical accuracy: ± 0.2mm / 10m
Automatic leveling range: ±3
Waterproof grade: IP-54
Working range: about 25m in diameter
Working time: about 5 hours
Green light working temperature: -5℃~ 50℃
Blue light working temperature: -20℃~ 50℃
Red light working temperature: -20°C~ 50°C (requires a personalized custom)
Safety Precautions
- Because of Laser radiation should not look directly at the laser beam;
- Class 2 laser crystal, harmless to the human body;
- Forbidden to heavy press or vibrate;
- The product shall be placed in the warehouse with ventilation, drying, heat-insulated, and fireproofing, and it is strictly prohibited to contact with corrosive materials;
- Loading, unloading, and use of products shall be handled gently, and shall not be thrown or dropped;
Daily maintenance and attention
- Daily maintenance
- Please store the machine in a dry, ventilated, constant temperature and dust-free place;
- please wipe the shell glass frequently to ensure the light transmission;
- when not in use for a long time, please release the locking switch for half an hour regularly to ensure that the bearing swings flexibly.
Attention
- check whether the horizontal line and vertical line are accurate before each use, otherwise, the construction loss caused by an inaccurate laser line has nothing to do with our company;
- nonprofessionals, do not disassemble the machine;
- please avoid severe vibration, collision, and falling of the machine;
- please pay attention to locking the locking switch after use;
- do not wipe the instrument with organic solvent.
Functions and features
Functions:
- The machine is inclined to 3° and automatically leveled;
- Alarm function beyond the safe range;
- The magnetic damping compensation system ensures fast leveling time;
- 360° rotatable base, and equipped with a fine adjustment mechanism, can make the machine quickly find the target;
- It can be used with a tripod to adjust the working height of the machine.
Features:
- A 360° horizontal line can be drawn on the wall;
- Two 360° vertical lines can be drawn on the wall; (the 2D model has only one 360° vertical line)
Instructions
- Place the instrument on the tripod, T-type wall mounting bracket, or lifting platform as needed;
- Push the main power switch forward to the position and the machine starts to work. The horizontal window automatically opens and produces four horizontal laser rays;
- Touch the H key on the touch panel to control horizontal opening and closing;
- Touch the V key on the touch panel once, open a vertical window with one click (tick), repeat again, the second vertical window opens, and the third touch closes two vertical windows;
- Long touch the key for more than 3 seconds, and a click(tick) will be heard, turning on the diagonal function. At this time, you can adjust it to the angle you want without alarm or flashing. Touch this key again for more than 3 seconds, and with one click (tick) to release this C function, the instrument works normally.
Note : The positive and negative terminals of the battery are properly installed. Please remove the battery if it is not used for a long time. Please charge for more than 10 hours when you use it for the first time. Please turn off the main switch after use. Please use the charger that matches the machine to charge. Please use this machine in the environment where this machine is described.
- Align the laser line closer to the food wall A and level the measuring instrument to find the intersection of the laser line on wall A and mark the center of the point (point I)
- Rotate the measuring instrument 180 degrees to level the instrument, find the intersection of the laser line on wall B, and mark the center of the point (point II)
- Move the measuring instrument closer to wall B (without rotating the measuring instrument), start the measuring instrument, and level the instrument. Adjust the height of the measuring instrument (with a tripod, if necessary, use the spacer), so that the intersection of the laser lines is accurately projected on point II of wall B
- Rotate the measuring instrument 180 degrees, but you can not change the height of the measuring instrument, adjust the measuring instrument, let the vertical laser line pass through point I of wall A, let the measuring instrument level, and make a mark on the light intersection point of wall a (point III) The difference d between wall point A and point III is the actual height deviation of the measuring instrument.
You can use the following formula to calculate the maximum allowable deviation, dmax, dmax = twice the wall spacing x 0.2 mm / m.
Example : If the wall spacing is 5 meters, then the maximum allowable deviation dmax = 2×5 meters x 0.2 mm / m = 2 mm. Therefore, the distance between the marks should not exceed 2 mm.
Product diagram
- control panel
- battery
- switch
- 360° horizontal line 1
- 360° vertical line 1
- 360° vertical line 2
- 360° horizontal line 2
- vertical lifting platform
- A horizontal line switch
- B OUTDOOR slash switch
- C vertical line switch
During the warranty period, the following situations are not covered by the warranty
- Improper use leads to human damage
- Damage due to improper transportation after-sale
- Damage caused by failure to use the original accessories of the company as required Any self-modified, disassembled, and repaired product
- Replacement of worn parts
- Any natural wear
Common problems
- After the receiving switch is turned on, the blister backlight will flash, which is a working signal indicating that it is in the receiving state, which is a normal phenomenon;
- The laser line flashes to prove that the machine is not in the setting range, please adjust the level through the legs;
- The laser line appears blurred. Please wipe the outer glass with a clean cotton cloth.
Attention
- nonprofessionals, do not disassemble the machine;
- please avoid severe vibration, collision, and falling of the machine;
- please pay attention to locking the locking switch after use;
- do not leave the battery in the machine to avoid leakage of battery liquid;
- do not look directly at the laser line. It should be used with protective glasses;
- do not wipe the instrument with organic solvent.
Certificate
- Name:
- Model:
- No.:
- Examiner:
- Date:
User save a copy (please save this part properly)
Warranty Card The user must present a copy of the card and an official invoice
at the time of warranty to confirm your warranty. service.
User name:
Please note that the conditions listed on the back are not guaranteed.
Receipt (please fill it in and send it back)
To ensure that you can enjoy the above warranty service, please fill in all
forms and send the “receipt” back to our company within 7 days, which will
take effect on the date of receiving the receipt!
User name:
FCC Warning:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interferenc e to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution : Any changes or modifications to this device not explicitly approved by the manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0cm between the radiator and your body.