Airpura T600DLX Heavy Tobacco Smoke Air Purifier Instruction Manual
- October 27, 2023
- Airpura
Table of Contents
- Airpura T600DLX Heavy Tobacco Smoke Air Purifier
- To open the filter chamber
- To close the filter chamber
- TO BEGIN USING YOUR AIRPURA
- FILTER MAINTENANCE AND REPLACEMENT
- Technical specifications
- Air purifiers models and filter configurations
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Airpura T600DLX Heavy Tobacco Smoke Air Purifier
To open the filter chamber
To close the filter chamber
TO BEGIN USING YOUR AIRPURA
Inspect the exterior of your Airpura to verify there is no damage from shipping. If any damage is noted, please follow the instructions from the distributor returns policy.
- Wipe the unit with a damp cloth to remove any dust from the packaging
- Plug the unit into a regular grounded 110-volt outlet
- Turn on the unit to MAX and allow it to run for at least 30 minutes
- Set the variable speed control to the level you wish
- The most efficient way to use your Airpura for regular air quality maintenance is to run it at a low speed 24 hours a day 7 days a week.
- Always maintain a humidity level of 40% or less in your home to ensure the unit is operating at optimal levels. When using purifier with a dehumidifier, please keep the dehumidifier at least 6 feet away.
FILTER MAINTENANCE AND REPLACEMENT
The Prefilter
Can be vacuumed from the exterior of the unit once a month or more often.
Should be replaced at least after 12 months of use
To vacuum the Prefilter
- Use the brush attachment on your vacuum cleaner
- Vacuum slowly around the mesh surface of the filter chamber
IMPORTANT SAFETY NOTE
Please ensure air purifier is turned OFF when plugging into a power source.
Failure to do so may result in motor potentially stalling and/or burning.
Technical specifications
-
Odor, airborne chemical and voc control
26 lbs super enhanced activated Carbon 13″H x 13.25″OD x 7.5″ID -
Carbon bed (Optional)
3 in deep x 570 in2 surface -
Tar removal
Special TarBarrier filter 570 in2 x 1 in deep -
Particle supression HepaBarrier
-
Airflow 560 cfm
More cfm than any other compact unit available -
Housing
Powder coat steel -
Size
23 in x 15 in -
Weight
49 lbs total -
Watts
115 or 220 volts -
Sound Level at 6 feet 34.2 db on low
57.2 db on high (Room level 25.1 db) -
Voltage options 115 or 220 volts
Air purifiers models and filter configurations
Prefilter | Carbon |
---|---|
Alternates | Cotton Prefilter Poly Prefilter |
Upgrade |
Potassium Iodide, Coconut Shell Carbon)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>