Airpura T700 DLX Heavy Tobacco Smoke Air Purifier User Guide

June 5, 2024
Airpura

T700
DLX

OPERATING & FILTER REPLACEMENT DIRECTIONS


Turn over the Airpura| Remove the 4 retaining screws| Take off the cover| Remove the gasket| Position the Prefilter inside the filter chamber| Place a felt gasket at the bottom  of the filter chamber

Place the HI-C filter around the Hepa filter and Attach the HI-C filter with the elastic bands| Unfold the filter slider (Supplied with replacement filters or on request Part#6F 001)| Roll it into a  spiral| Insert the tube into the  filter chamber inside the Prefilter| Let the spiral open to fill the opening
Airpura T700 DLX Heavy Tobacco Smoke Air Purifier - fig
1

Open the top of the spiral to make a slight funnel| Insert the Carbon canister into the funnel  and hold it straight| Let the canister slide  down thefilter slider| Pull the filter slider up out  of the cavity using both hands and let the canister slide to the  bottom of the cavity| Remove the filter slider and fold it for further  se| Slide in the Hepa filter

To close the filter chamber


Replace
the gasket| Position the indentation in the cover into the center of the HEPA filter| Replace
the 4 screws and tighten| Turn the Airpura
back on casters

TO BEGIN USING YOUR

AIRPURA

Inspect the exterior of your Airpura to verify there is no damage from shipping.
If any damage is noted, please follow the instructions from the distributor returns policy.
Wipe the unit with a damp cloth to remove any dust from the packaging
Plug the unit into a regular grounded 110-volt outlet
Turn on the unit to MAX and allow it to run for at least 30 minutes
Set the variable speed control to the level you wish
The most efficient way to use your Airpura for regular air quality maintenance is to run it at a low speed 24 hours a day 7 days a week.
Always maintain a humidity level of approximately 40% to ensure the unit is operating at optimal levels. When using a purifier with a dehumidifier, please keep the dehumidifier at least 6 feet away.

FILTER MAINTENANCE AND REPLACEMENT

The Prefilter
Can be vacuumed from the exterior of the unit once a month or more often.
Should be replaced at least after 12 months of use
To vacuum the Prefilter
Use the brush attachment on your vacuum cleaner
Vacuum slowly around the mesh surface of the filter chamber

IMPORTANT SAFETY NOTE
Please ensure air purifier is turned OFF when plugging into a power source failure to do so may result in the motor potentially stalling and/or burning.

Technical specifications

Odor, airborne chemical
and voc control
26 lbs super enhanced activated
Carbon 13″H x 13.25″OD x 7.5″ID
Carbon bed (Optional)
3 in deep x 570 in² surface
Tar removal
Special TarBarrier filter 570 in² x 1 in deep
Particle suppression
HepaBarrier
Air flow 635 cfm
More cfm than any other
compact unit available
Housing
Powder coat steel
Size
23 in x 15 in
Weight
49 lbs total
Watts
115 or 220 volts
Sound Level
30.2 DB on low (at 6 feet)
63.0 dB on high (635 cm)
at test conditions
Voltage options
115 or 220 volts

Air purifiers models and filter configurations

Prefilter Carbon

Alternates| Cotton Prefilter Poly  Prefilter|
Upgrade| | 26 lbs, Impregnated Carbon Filter (35/65 % Blend: KI/ Potassium Iodide, Coconut Shell Carbon)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals