INSTALLATION & MAINTENANCE GUIDE
Important Safety Instructions: Read Before Installation
This fixture is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.
These instructions do not intend to cover all variations in installation, operation maintenance, or mounting situations.
- Make sure that the power is turned OFF before installing or servicing this luminaire.
- WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from the pool, spa, or fountain.
- This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
- Wiring connections must be made with UL-listed wire connectors that are suitable for outdoor use.
- The unit low voltage cable should:
a. Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck;
a. Not be buried except for a maximum of 6 inches (15.2 cm) in order to connect to the main low voltage cable, and
a. Have the length cut off so that it is connected to a connector within 6 inches (15.2 cm) from the building structure, a luminaire, or fitting.
Important Safety Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – TO REDUCE THE RISK OF FIRE OR INJURY TO PERSONS.
- Turn off/unplug and allow to cool before reducing the lamp.
- Lamp gets HOT quickly! Contact only switch/plug when turning on.
- Do not touch the hot lens, guard, or enclosure.
- Keep the lamp away from materials that may burn.
- Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may damage the lamp.
- Do not operate the luminaire fitting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
Package Contents
A. (1) Fixture
B. (1) Fixture Chain
C. (1) Chain Link
D. (1) Mounting Bracket
E. (3) Self-tapping Screws
F. (3) Flat Washers
Parts Required (Sold Separately)
A. (1) LED MR16 Lamp or (1) Bi-Pin Brass Puck Light
Product Dimensions
Remove Shade
Remove the top of the shade from the bottom of the shade to expose the socket.
Two kinds of bulbs are suitable for this fixture.
- MR16 Bulb: Option 1
- Bi-Pin Brass Puck Light: Option 2
Option 1: MR16 Bulb
Install MR16 Bulb
Insert the MR16 bulb with the correct wattage and type marked on the fixture
label.
CAUTION: This fixture is for LED use only. Do not exceed the maximum
wattage marked on the luminaire label.
NOTE: DO NOT touch the MR16 bulb with bare hands. Use a soft cloth to
handle the MR16 bulb.
Go to Step 3 to complete the installation.
Option 2: Bi-Pin Puck Light
Remove Clips
Remove the clip from the socket by removing the screws.
Install Bi-Pin Brass Puck Light
Insert the Bi-pin brass puck light into the socket and secure it in place with
the two screws previously removed from the clip.
CAUTION: This fixture is for LED use only. Do not exceed the maximum
wattage marked on the luminaire label.
NOTE: DO NOT touch the Bi-pin brass puck light with bare hands.
Use a soft cloth to handle the puck light.
Go to Step 3 to complete the installation.
Install Shade
Thread the top of the shade back onto the bottom of the shade.
Install Mounting Bracket
Attach the mounting bracket onto the desired ceiling surface. Secure with the
flat washers and self-tapping screws.
Note: Wall anchors are required for certain installation conditions
(concrete or brick walls). Mark on the desired ceiling surface for wall
anchors by using the holes on the mounting bracket. Remove the mounting
bracket and drill proper holes on the desired ceiling surface and then insert
the wall anchors.
Attach Fixture to Mounting Bracket
Adjust the fixture chain to the desired length by removing the links if
needed.
( Note: Pliers are required for this step).
With the fixture chain unattached to the fixture loop on top of the fixture
body; or the ceiling loop on the underside of the mounting bracket, pull the
supply wires through the fixture chain alternating between the links.
After the wires are through the fixture chain, pull the supply wires up and
around the backside of the mounting bracket.
Attach one end of the fixture chain to the fixture loop at the top of the
fixture body.
Lift the fixture body and fixture chain up and attach the other end of the
fixture chain onto the ceiling loop on the bottom of the mounting bracket with
the chain link.
The fixture will now hang safely. Close the chain loop at the ceiling loop.
Wire Connections
Strip both leads from the luminaire pigtail. Connect the leads from the luminaire supply cable to the transformer (sold separately).