FLASH F7300254 Water Effect 200W IP65 User Manual
- June 6, 2024
- FLASH
Table of Contents
FLASH F7300254 Water Effect 200W IP65
INTRODUCTION
THANK YOU FOR PURCHASING Water Effect 200W IP65. FOR SAFETY REASONS AND TO ENSURE A TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.
- Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.
- Unpack and check carefully there is no transportation damage before using the fixture.
- Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture.
- It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
- Disconnect main power before servicing and maintenance.
- Use safety chain when fixing this fixture. Don’t handle the fixture by taking its head only, but always by taking its base.
- The maximum ambient temperature is: +-350C Don’t operate it where the temperature is higher than this.
- In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type of spare parts.
- Do not connect the device to any dimmer pack.
- Do not touch any wire during operation and there might be a hazard of electric shock.
- To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
- The housing must be replaced if they are visibly damaged.
- Do not look directly at the LED light spot while the fixture is on.
WARNING!
WARNING! The Water Effect 200W IP65 has a powerful pan motor. The torque
reaction when the head is panned suddenly can cause the base to move if the
fixture is standing unsecured on a surface. Do not apply power to the Water
Effect 200W IP65 unless the baase is securely fastened to a surface or to
rigging hardware.
WARNING! Use 2 clamps to rig the fixture. Do not hang the fixture from
only one clamp. Lock each clamp with both 1/4-turn fasteners. Fasteners are
locked only when turned a full 900 clockwise.
WARNING! When clamping the fixture to a truss or other structure at any
other angle than with the yoke hanging vertically downwards, use two clamps of
half-coupler type. Do not use any type of clamp that does not completely
encircle the structure when fastened.
WARNING! Position or shade the head so that the front lens will not be
exposed to sunlight or any other strong light source from any angle – even for
a few seconds. See Figure 2. The Water Effect 200W IP65 lens can focus the
sun’s rays, creating a potential fire hazard and causing damage.
IMPORTANT! Do not point strong light output from other fixtures at the
Water Effect 200W IP65, as intense illumination can damage the display.
Figure 2. Lenses can focus sunlight and strong light, presenting a risk of fire and damage to the fixture. Shield or shade the head if necessary.
PRODUCT INFORMATION
- Light Source: 1 pc LED 230W White
- LED life: 50000 hours
- Color Temperature: 6500-7000K
- Angle: 10,20,30,45, 60 Optional
- Light Spot: Circle/Splice Square
- Dimmer: 0-100% linear dimmer.
- Cooling system: Fan wind cooling
- Display: LCD display
- Focus: Manual
- Electronic positioning function
- Light source overheat protection and intelligent offline control mode
- Smart off-line autorun mode. pre-program the effects in the fixture and when it is power ON, it will play automatically
- Focus: Manual Focusing
- Temperature: Light Source’s temperature is monitored real-time
- Angle adjusts: Up/Down – 180°
- Inner electronics with moisture-proof protection
- Working environment: -25 to +35
- Running Mode: Manual. Auto. Master/Slave
- Protection IP65
- Net Weight: 11 kg + (Case 14,2 kg)
- Dimensions: H(34 )Wx(30)xD(36) cm
- Interchangeable Gobos: 37.3 mm diameter
weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.
INSTALLATION
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s
CONNECTION
The device is equipped with the following interfaces:
- DMX (in/out): XLR 3-pin socket
- Power (in/out): powerCON socket
Connecting DMX signal
The connection is performed using a cable with XLR-female -> XLR-Male plugs.
CAUTION! At the last fixture, the DMX signal has to be terminated with a terminator. Solder a 120Ω resistor between signal (-) and signal (+) into an XLR plug and plug it in the DMX output of the last fixture.
Voltage specification
Input Voltage | Total Power | Frequency |
---|---|---|
110-240V | 250W | 50/60Hz |
Connecting power supply
The connection is performed using a power cable with a PowerCon connector (included). The device must be operated by qualified personnel. Make sure that the power grid supply parameters are consistent with device parameters and limitations are not exceeded.
CAUTION! In the case of cable, damage do not attempt to repair. Replacement or repair can be made only on the manufacturer or by a person with appropriate permissions. Using a lamp, the change rate of power voltage should be within ± 10%, if the voltage is too high, it will shorten the light’s life; if it’s not enough, the lamp will be dark. Please restart it after turning off light for 20 minutes until full-cooling. Frequent switching will reduce the life span of lamps and bulbs; intermittent using will improve the life of bulbs and lamps.
Menu Structure:
DMX CHANNELS
Main | Menu 2 Level | Menu 3 Level | Description |
---|
Setting
| Mode| DMX| slave state, recive dmx signal
DMX address| 001-512| enter to edit, up or down change, enter to save
Channels| 5CH| Channels
No DMX| Keep| old state to continue
| Delete| stop running
| Black| 30 seconds off backlight
| DMX address| 30 seconds off backlight
Screen Protection| Off| Backlight shut off
Overheat protection| 085| 0-99 range, exceed temperature, power reduce,
temperature down, power raise up
Manual
| Dimmer| 0-255|
Strobe| 0-255|
Gobo| 0-255|
Gobo Rot| 0-255|
RESET| Enter/Cancel| Enter to start reset
System
| VER| | version no.
this time, use| | this time, use time
total use time| | total use time
temperature| | now temperature
Advance| gobo correction| -128 +127| motors data correction
| restore default| | factory data restore
| hall| ON| 0 or 1
0.81| | | screen overturn
EN/CH| | | change language
CH Mode
CH | Funkcja | Value | Description |
---|---|---|---|
1 | Dimmer | 0-255 | Dimmer general, dark to bright |
2 | Strobe | 0-5 | none |
6-255 | strobe from slow to fast |
3
| ****
Color Wheel
| 0-9| white
10-19| red
20-29| green
30-39| blue
40-49| pink
50-59| cyan
60-139| Color linear
140-197| From fast to slow, clockwise
198-255| From slow to fast, anticlockwise
5
| ****
Water 1
| 0-15| none
16-134| clockwise rotation, slow to fast
135-255| anticlockwise rotation, fast to slow
6
| ****
Water 2
| 0-15| none
16-134| clockwise rotation
135-255| anticlockwise rotation, fast ot slow
7| Reset| 0-249| none
250-255| reset
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>