WARNING
- The Led Moving Head (LMH) has a powerful pan and tilt motor. The torque reaction when the head is panned suddenly can cause the base to move if the fixture is standing unsecured on a surface. Do not apply power to the LMH unless the baase is securely fastened to a surface or to rigging hardware.
- Use 2 clamps to rig the fixture. Do not hang the fixture from only one clamp. Lock each clamp with both 1/4-turn fasteners. Fasteners are locked only when turned a full 900 clockwise.
- When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.
- Position or shade the head so that the front lens will not be exposed to sunlight or any other strong light source from any angle – even for a few seconds. See Figure 1. The LMH lens can focused the sun’s rays, creating a potential fire hazard and causing damage.
- IMPORTANT! Do not point strong light output from other fixtures at the LMH, as intense illumination can damaged the display.
INTRODUCTION
THANK YOU FOR PURCHASING 4x15W RGBW ZOOM. FOR SAFETY REASONS AND TO ENSURE
THE TROUBLE-FREE OPERATION, CA-REFULLY READ THE INSTRUCTIONS.
SAFETY INFORMATION
- Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruc-tion booklet.
- Unpack and check carefully there is no transportation damage before using the fixture.
- Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture.
- It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
- Disconnect main power before servicing and maintenance.
- Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, but always by taking its base.
- Maximum ambient temperature is: 40°C Don’t operate it where the temperature is higher than this.
- In the event of serious ope-rating problem, stop using the fixture immediately. Never try to repair the fixture by yourself.
- Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
- Do not connect the device to any dimmer pack.
- Do not touch any wire during operation and there might be a hazard of electric shock.
- To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
- The housing must be replaced if they are visibly damaged.
- Do not look directly at the light spot while the fixture is on.
PRODUCT INFORMATION
-
Light Source:
LED OSRAM 4x15W RGBW -
Power consumption: 51W
-
Power supply voltage: 100-240V, 50/60Hz AC
-
PAN range: 540°
-
TILT range: 270°
-
Features: Zoom, Macro Colors
-
Operating modes: DMX, Auto, Sound-controlled, Master, Slave,
-
DMX channel mode: 14/16/19
-
IP Rating: IP20
-
Housing made: ABS
-
Cooling: Active
-
AC IN: IEC – C14
-
3-Pin XLR DMX Input/Output
-
Net Weight: 3 kg
-
Dimensions: H(29)xW(26,5)xD(22) cm
INSTALATION
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.
Regardless of the rigging option ypu chose for our fixture, always be sure to secure your fixture with safety cable. The fixture provides a builit-in rigging point for a safety cable on the hanging bracket as illu-strated above. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle.
CONNECTION
The device is equipped with the following interfaces:
- DMX (in/out): XLR 3(5)-pin socket
- Power (in): IEC- C14
The connection is performed using cable with XLR-female -> XLR-Male plugs.
CAUTION At the last fixture, the DMX signal has to be terminated with a terminator. Solder a 120Ω resistor between signal (-) and si-gnal (+) into a XLR plug and plug it in the DMX output of the last fixture.
Diagram of connection of devices by DMX cable.
The connection is performed using power cable with TrueCON con-nector
(included). The device must be operated by qualified personnel.
CAUTION! In the case of cable damage do not attempt to repair. Repla-
cement or repair can be made only on the manufacturer or by a person with
appropriate permissions
Using lamp, the change rate of power voltage should be within ±10%, if the voltage is too high, it will shorten the light’s life; if it’s not enough, the lamp will be dark. Please restart it after turning off light for 20 mi-nutes until full-cooling. Frequent switching will reduce the life span of lamps and bulbs; intermittent using will improve the life of bulbs and lamps.
Voltage Specyfication
Input Voltage | Amperage | Frequency | Total Power |
---|---|---|---|
100-240[V] AC | 0.44[A] | 50[Hz] | 51[W] |
Manual Menu
- ADDR – enter – 1 – 512
- CHND – enter – 14 ch / 16 ch / 19 ch
- SLND – enter – nast / sl 1 / sl 2
- SHND – enter – sh 1 / sh 2 / sh 3 / sh 4
- AUTO – enter – on / off SOUND – enter – on / off SENS – enter – 0 – 100 BLND – enter – yes / no LED – on / off
- DISPLAY– enter – enter rotation
- PAN INWERT – enter – on / off
- TILT INWERT – enter – on / off
- BALANS
- enter – red 1 – enter – 125 – 255
- up/down – green 1 – enter – 125 – 255
- up/down – blue 1 – enter – 125 – 255
- up/down – red 2 – enter – 125 – 255
- up/down – green 2 – enter – 125 – 255
- up/down – blue 2 – enter – 125 – 255
- MANUAL – enter – pan – enter – 000 – 255
- up/down – tilt – enter – 000 – 255
- up/down – zoom – enter – 000 – 255
- up/down – red 1 – enter – 000 – 255
- up/down – green 1 – enter – 000 – 255
- up/down – blue 1 – enter – 000 – 255
- up/down – white 1 – enter – 000 – 255
- up/down – red 2 – enter – 000 – 255
- up/down – green 2 – enter – 000 – 255
- up/down – blue 2 – enter – 000 – 255
- up/down – white 2 – enter – 000 – 255
- up/down – dimmer – enter – 000 – 255
- up/down – strobe – enter – 000 – 255
- TEST– enter
- RESET – enter
DMX CHART
14 CH
CH | VALUE | DESCRIPTION |
---|---|---|
1 | 000-255 | PAN |
2 | 000-255 | TILT |
3 | 000-255 | ZOOM |
4 | 000-255 | RED 1 |
5 | 000-255 | GREEN 1 |
6 | 000-255 | BLUE 1 |
7 | 000-255 | WHITE 1 |
8 | 000-255 | RED 2 |
9 | 000-255 | GREEN 2 |
10 | 000-255 | BLUE 2 |
11 | 000-255 | WHITE 2 |
12 | 000-255 | DIMMER |
13 | 000-255 | STROBO |
14 | 000-255 | RESET |
14 CH
CH | VALUE | DESCRIPTION |
---|---|---|
1 | 000-255 | PAN |
2 | 000-255 | TILT |
3 | 000-255 | ZOOM |
4 | 000-255 | RED 1 |
5 | 000-255 | GREEN 1 |
6 | 000-255 | BLUE 1 |
7 | 000-255 | WHITE 1 |
8 | 000-255 | RED 2 |
9 | 000-255 | GREEN 2 |
10 | 000-255 | BLUE 2 |
11 | 000-255 | WHITE 2 |
12 | 000-255 | DIMMER |
13 | 000-255 | STROBO |
14 | 000-007 | EMPTY |
008-127 | MACROCOLOR | |
128-191 | JUMP CHANGING PROGRAME | |
192-255 | GRADUAL CHANGING PROGRAME | |
15 | 000-255 | SPEED MACROCOLOR |
16 | 000-255 | RESET |
19 CH
CH | VALUE | DESCRIPTION |
---|---|---|
1 | 000-255 | PAN |
2 | 000-255 | TILT |
3 | 000-255 | ZOOM |
4 | 000-255 | PAN / TILT / ZOOM – SPEED |
5 | 000-255 | RED 1 |
6 | 000-255 | GREEN 1 |
7 | 000-255 | BLUE 1 |
8 | 000-255 | WHITE 1 |
9 | 000-255 | RED 2 |
10 | 000-255 | GREEN 2 |
11 | 000-255 | BLUE 2 |
12 | 000-255 | WHITE 2 |
13 | 000-255 | DIMMER |
14 | 000-007 | STROBO |
15 | 000-007 | EMPTY |
008-127 | MACROCOLOR | |
128 – 191 | JUMP CHANGING PROGRAME | |
192 – 255 | GRADUAL CHANGIG PROGRAME | |
16 | 000-255 | SPEED MACROCOLOR |
17 | 000-255 | AUTO ROTATION PAN / TILT |
18 | 000-255 | SPEED AUTO ROTATION PAN / TILT |
19 | 000-255 | RESET |
FLASH-BUTRYM Sp.j.
Skarbimierzyce 18 · 72-002 Dołuje · POLAND
WWW.FLASH-BUTRYM.PL
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>