Flash-Butrym F9700385 LED Strobe
Product Information
Specifications:
- Light Source: 960x (5050) RGB + 120x (7070) White LEDs
- Power Consumption: 300W
- Power Supply Voltage: 100-240V, 50/60Hz AC
- Operating Modes: DMX512, Self-Walking, Master-Slave, Voice Control, with RDM function
- DMX Channel Mode: 4CH / 12 CH / 86 – 108 CH
- IP Rating: IP65
- Housing Material: Alu + Steel
- Cooling: Active
- AC IN: Dedicated IP65 power plug
- DMX Input/Output: Dedicated 3-Pin XLR DMX IP65
- Net Weight: 10.6 kg (11.8 kg)
- Net Dimensions: H(15)xW(62)xD(30) cm
- Pack Size: H(31)xW(70)xD(38) cm
Product Usage Instructions
Installation:
- Unpack and carefully check for any transportation damage before using the fixture.
- Ensure that the voltage and frequency of the power supply match the requirements of the fixture.
- Ground the yellow/green conductor to earth to avoid electric shock.
- Use the safety chain when fixing the fixture. Handle the fixture by its base, not just the head.
Connection:
- The device has DMX (in/out) and power (in/out) interfaces with dedicated IP65 connectors.
- Connect using cables with XLR-female -> XLR-Male plugs for DMX connection.
- At the last fixture, terminate the DMX signal with a terminator by soldering a 120 resistor between signal (-) and signal (+) into an XLR plug.
DMX Chart:
Refer to the provided DMX chart for detailed information on operating modes and channel configurations.
Frequently Asked Questions
Q: Can I repair the fixture myself if there is an issue?
A: No, it is advised not to repair the fixture by yourself. Please contact the nearest authorized technical assistance center for any repairs.
Q: What should I do if there is cable damage?
A: In case of cable damage, do not attempt to repair it yourself. Replacement or repair should be done by the manufacturer or a person with appropriate permissions.
LED STROBE IP65 24xRGB+12xWhite
User Manual
- WARNING! Use clamp to rig the fixture.
- WARNING! When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.
- WARNING! Position or shade the bar so that the front lens will not be exposed to sunlight or any other strong light source from any angle – even for a few seconds. See Figure 1. The LED STROBE lens can focused the sun’s rays, creating a potential fire hazard and causing damage.
- IMPORTANT! Do not point strong light output from other fixtures at the LED STROBE, as intense illumination can damaged the display.
INTRODUCTION
THANK YOU FOR PURCHASING LED STROBE. FOR SAFETY RE-ASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CARE-FULLY READ THE INSTRUCTIONS.
SAFETY INFORMATION
- Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruc-tion booklet.
- Unpack and check carefully the-re is no transportation damage be-fore using the fixture.
- Before operating, ensure that the voltage and frequency of po-wer supply match the power requirements of the fixture.
- It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
- Disconnect main power before servicing and maintenance.
- Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, but always by taking its base.
- Maximum ambient temperature is: 40°C Don’t operate it where the temperature is higher than this.
- In the event of serious ope-rating problem, stop using the fixture immediately. Never try to repair the fixture by your-self.
- Repairs carried out by unskil-led people can lead to damage or malfunction. Please contact the nearest authorized techni-cal assistance center. Always use the same type spare parts.
- Do not connect the device to any dimmer pack.
- Do not touch any wire during operation and there might be a hazard of electric shock.
- To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
- The housing must be repla-ced if they are visibly damaged.
- Do not look directly at the li-ght spot while the fixture is on.
PRODUCT INFORMATION
-
Light Source:
960x (5050) RGB + 120x (7070) White LEDs -
Power consumption: 300W
-
Power supply voltage:
100-240V, 50/60Hz AC -
Operating modes: DMX512,
Self-Walking, Master-Slave, Voice Control, with RDM function -
DMX channel mode
4CH / 12 CH / 86 – 108 CH -
IP Rating: IP65
-
Housing made: Alu + Steel Cooling: Active
-
AC IN: dedicated IP65
-
power plug
-
dedicated 3-Pin XLR DMX IP65 Input/Output
-
Net Weight: 10.6 kg (11.8 kg) Net Dimensions:
-
H(15)xW(62)xD(30) cm
-
Pack Size:
-
H(31)xW(70)xD(38) cm
INSTALLATION
- The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 ti-mes of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it. The fixture may be installed in any orientation, but if installed horizontally with a downward beam angle, water can potentially pool in the fan wells. Under normal operation the moisture will evaporate. However, in locations with high rainfall, you may wish to fabricate a rain shield above the fixture, or modify the position and orientation of the fixture to minimize pooling. Two quarter-turn brackets are supplied with the fixtre if it is to be flown above the ground. Rig the fixture to a support truss or structure using the supplied brackets and suitable clamps. Fasten a safety cable between the support structure and the attachment point on the fixture. The safety cable must be able to bear at least 10 times the weight of the fixture.
The package includes
- LED STROBE (1 pc)
- IP65 DMX cable (1 pc)
- IP65 Power cable (1 pc)
- Omega Bracket (2 pcs)
- User Manual (1 pc)
CONNECTION
The device is equipped with the following interfaces:
- DMX (in/out): dedicated IP65 XLR 3-pin socket
- Power (in/out): dedicated IP65 power plug The connection is performed using cable with XLR-female -> XLR-Male plugs.
CAUTION! At the last fixture, the DMX signal has to be terminated with a terminator. Solder a 120Ω resistor between signal (-) and si-gnal (+) into a XLR plug and plug it in the DMX output of the last fixture.
Diagram of connection of devices by DMX cable.
The connection is performed using power cable with IP65 connector (included). The device must be operated by qualified personnel.
CAUTION! In the case of cable damage do not attempt to repair. Repla-
cement or repair can be made only on the manufacturer or by a person with
appropriate permissions
Using lamp, the change rate of power voltage should be within ±10%, if the
voltage is too high, it will shorten the light’s life.
Voltage Specification
Input Voltage | Frequency | Total Power |
---|---|---|
100-240[V] AC | 50/60[Hz] | 350[W] |
Control Menu
- On the fixture display, four buttons from left to right:
- „MENU” button. It is the Function menu.
- „Up” button. Modify data up.
- „Down” button. Modify data down.
- „ENTER” button. Save the modified data and exit the edit state.
- In the editing state, if the „Enter” button is not pressed, the modified data will not be saved and will be lost after shutdown.
Display Function Menu
Main Menu | Submenu 1 | Submenu 2 | Function description |
---|
Addr
|
d001/d512
| | Address code, press the OK key to enter the Subme- nu 1, the up or down
key to select the address code, press the OK key to save the address code.
CHAL| Ch4/CH11/ CH86| | Channel, press OK to enter Submenu 1, up or down key
to select chennel, press OK to save channel.
Auto| CA50| 01-50|
Press the Confirm key to go to Submenu 1, the up or down key to select the self-walking type, then press the Confirm key to go to Submenu 2, the up or down key to select the self-walking speed, press the Confirm key to save the self-walking type and self-walking speed, and press the menu key to return to the manu.
| CB50| 01-50
| CC50| 01-50
| CD50| 01-50
| CE50| 01-50
| CF50| 01-50
| CG50| 01-50
| CH50| 01-50
| CJ50| 01-50
| CL50| 01-50
| CN50| 01-50
| CO50| 01-50
| CP50| 01-50
| CQ50| 01-50
| CR50| 01-50
| CS50| 01-50
| CT50| 01-50
| CU50| 01-50
| CY50| 01-50
SOUD| SO01-SO99| | Voice-activated mode
Stat
|
r000
|
r000-r255
| Red manual dimming, press OK to enter Submenu 2, up key or down key to
select brightness size, bright- ness from small to large. 000 is off, and 255
is the maximum.
|
g000
|
g000-g255
| Green manual dimming, press OK to enter Subme- nu 2, up key or down key to
select brightness size, brightness from small to large. 000 is off, and 255 is
the maximum.
|
b000
|
b000-b255
| Blue manual dimming, press OK to enter Submenu 2, up key or down key to
select brightness size, bri- ghtness from small to large. 000 is off, and 255
is the maximum.
|
w000
|
w000-b255
| White manual dimming, press OK to enter Subme- nu 2, up key or down key to
select brightness size, brightness from small to large. 000 is off, and 255 is
the maximum.
| t000| t000-b255|
Temp| C000| TO85| Temperature regulation
Rest| On/Off| | Factory data reset
DMX CHART
4 Channel Mode
Channel | Value | Function Declaration |
---|---|---|
1 | 000-255 | R Red light bead dimming |
2 | 000-255 | G Green light bead dimming |
3 | 000-255 | B Blue light bead dimming |
4 | 000-255 | W White light bead dimming |
12 Channel Mode
Channel | Value | Function Declaration |
---|---|---|
1 | 000-255 | Total Dimmer |
2 | 000-255 | Stroboscopic |
3 | 000-255 | Color bar, color of pattern effect, 32 values per color |
4 | 000-255 | RGB self-walking mode, one effect for every 5 values |
5 | 000-255 | RGB self-walking speed, from slow to fast |
6 | 000-255 | W strobing |
7 | 000-255 | W Self moving mode, with one effect for every 15 values, and |
brightness determined by 12 CH
8| 000-255| W Self moving speed, from slow to fast (self-walking effect
background color)
9| 000-255| R Red light bead dimming
(self-walking effect background color)
10| 000-255| G Green light bead dimming
(self-walking effect background color)
11| 000-255| B Blue light bead dimming
(self-walking effect background color)
12| 000-255| W White light bead dimming
(self-walking effect background color)
86-108 Channel Mode
Channel | Value | Function Declaration |
---|---|---|
1 | 000-255 | Dimmer |
2 | 000-255 | Strobe |
3 | 000-255 | 1 Red |
4 | 000-255 | 1 Green |
5 | 000-255 | 1 Blue |
6 | 000-255 | 2 Red |
7 | 000-255 | 2 Green |
8 | 000-255 | 2 Blue |
9 | 000-255 | 3 Red |
10 | 000-255 | 3 Green |
11 | 000-255 | 3 Blue |
12 | 000-255 | 4 Red |
13 | 000-255 | 4 Green |
14 | 000-255 | 4 Blue |
15 | 000-255 | 5 Red |
16 | 000-255 | 5 Green |
17 | 000-255 | 5 Blue |
18 | 000-255 | 6 Red |
19 | 000-255 | 6 Green |
20 | 000-255 | 6 Blue |
21 | 000-255 | 7 Red |
22 | 000-255 | 7 Green |
23 | 000-255 | 7 Blue |
24 | 000-255 | 8 Red |
25 | 000-255 | 8 Green |
26 | 000-255 | 8 Blue |
27 | 000-255 | 9 Red |
28 | 000-255 | 9 Green |
29 | 000-255 | 9 Blue |
30 | … | … |
31 | … | … |
… | … | … |
Channel | Value | Function Declaration |
--- | --- | --- |
72 | 000-255 | 24 Red |
73 | 000-255 | 24 Green |
74 | 000-255 | 24 Blue |
75 | 000-255 | White 1 |
76 | 000-255 | Empty |
77 | 000-255 | Empty |
78 | 000-255 | White 2 |
79 | 000-255 | Empty |
80 | 000-255 | Empty |
81 | 000-255 | White 3 |
82 | 000-255 | Empty |
83 | 000-255 | Empty |
84 | 000-255 | White 4 |
85 | 000-255 | Empty |
86 | 000-255 | Empty |
87 | 000-255 | White 5 |
88 | 000-255 | Empty |
89 | 000-255 | Empty |
90 | 000-255 | White 6 |
91 | 000-255 | Empty |
92 | 000-255 | Empty |
93 | 000-255 | White 7 |
94 | 000-255 | Empty |
95 | 000-255 | Empty |
96 | 000-255 | White 8 |
97 | 000-255 | Empty |
98 | 000-255 | Empty |
99 | 000-255 | White 9 |
100 | 000-255 | Empty |
101 | 000-255 | Empty |
102 | 000-255 | White 10 |
103 | 000-255 | Empty |
104 | 000-255 | Empty |
Channel | Value | Function Declaration |
--- | --- | --- |
105 | 000-255 | White 11 |
106 | 000-255 | Empty |
107 | 000-255 | Empty |
108 | 000-255 | White 12 |
Read User Manual Online (PDF format)