FLASH F7100443 LED PAR 28x10W RGBW Zoom User Manual

May 15, 2024
FLASH

FLASH F7100443 LED PAR 28x10W RGBW Zoom

FLASH-F7100443-LED-PAR-28x10W-RGBW-Zoom-PRODUCT

Product Information

Installation

The package includes:

  • LED PAR (1 pc)
  • Power cable type powerCON (1 pc)
  • Omega bracket (1 pc)
  • IR Remote (1 pc)
  • User Manual (1 pc)

Connection

The device is equipped with the following interfaces:

  1. DMX (in/out): XLR 3-pin socket
  2. Power (in/out): powerCON socket

The connection is performed using a cable with XLR-female -> XLR-Male plugs.

DMX Connection

DMX Signal Termination: At the last fixture, terminate the DMX signal with a terminator. Solder a 120 resistor between signal (-) and signal (+) into an XLR plug and plug it into the DMX output of the last fixture.

Power Cable Connection

Maximum Devices in Series: The maximum number of devices connected in series via the power cable is 5 pcs. Use the power cable with a powerCON connector (included).

Note: The device must be operated by qualified personnel. In case of cable damage, do not attempt to repair; replacement or repair should be done only by the manufacturer or a person with appropriate permissions.

Frequently Asked Questions

Q: What should I do if I encounter an operating problem with the fixture?

A: In the event of a serious operating problem, stop using the fixture immediately. Do not attempt to repair the fixture by yourself. Contact the nearest authorized technical assistance center for repairs.

Q: Can I connect the device to a dimmer pack?

A: No, do not connect the device to any dimmer pack to prevent damage or malfunction.

Q: How can I avoid electric shock while using the fixture?

A: It’s important to ground the yellow/green conductor to earth and always disconnect the main power before servicing and maintenance to avoid electric shock.

WARNING! Use clamp to rig the fixture.
WARNING! When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half- coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.
WARNING! Position or shade the bar so that the front lens will not be exposed to sunlight or any other strong light source from any angle – even for a few seconds. See Figure 1. The LED PAR lens can focused the sun’s rays, creating a potential fire hazard and causing damage.
IMPORTANT! Do not point strong light output from other fixtures at the LED PAR, as intense illumination can damaged the display.FLASH-F7100443-LED-PAR-
28x10W-RGBW-Zoom-FIG \(2\)

INTRODUCTION

THANK YOU FOR PURCHASING LED PAR. FOR SAFETY REASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS

SAFETY INFORMATION

  • Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.
  • Unpack and check carefully there is no transportation damage before using the fixture.
  • Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture.
  • It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
  • Disconnect main power before servicing and maintenance.
  • Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, but always by taking its base.
  • Maximum ambient temperature is: 40°C Don’t operate it where the temperature is higher than this.
  • In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself.
  • Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
  • Do not connect the device to any dimmer pack.
  • Do not touch any wire during operation and there might be a hazard of electric shock.
  • To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
  • The housing must be replaced if they are visibly damaged.
  • Do not look directly at the light spot while the fixture is on.

PRODUCT INFORMATION

  • Light Source:
    • 28x10W 4in1 RGBW LEDs
  • Power consumption: 200W
  • Power supply voltage:
    • 90-260V, 50/60Hz AC
  • Macros (CTO, CTB,
    • 2800-8000K)
  • Zoom 12°-60°
  • Operating modes: DMX512,
    • Manual, Auto, Sound-controlled,
    • Master/Slave, Sound active,
  • DMX channel mode
    • 13/29/55/07
  • IP Rating: IP20
  • Housing made: ABS
  • Cooling: Active
  • AC IN/OUT: powerCon
  • 3-Pin XLR DMX Input/Output
  • Net Weight: 3 kg
  • Gross weight: 3,5 kg
  • Net Dimensions:
    • H(14)xW(22)xD(27) cm
  • Pack Size:
    • H(31)xW(20)xD(33) cm

INSTALLATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it. The fixture may be installed in any orientation, but if installed horizontally with a downward beam-angle, water can potentially pool in the fan wells. Under normal operation the moisture will evaporate. However, in locations with high rainfall, you may wish to fabricate a rain shield above the fixture, or modify the position and orientation of the fixture to minimize pooling. Two quarter-turn brackets are supplied with the fixtre if it is to be flown above the ground. Rig the fixture to a support truss or structure using the supplied brackets and suitable clamps. Fasten a safety cable between the support structure and the attachment point on the fixture. The safety cable must be able to bear at least 10 times the weight of the fixture.

package includes

  1. LED PAR (1 pc)
  2. Power cable type
    • powerCON (1 pc)
  3. Omega bracket (1 pc)
  4. IR Remote (1 pc)
  5. User Manual (1 pc)

CONNECTION

The device is equipped with the following interfaces:

  1. DMX (in/out): XLR 3-pin socket
  2. Power (in/out): powerCON socket

The connection is performed using a cable with XLR-female -> XLR-Male plugs.

CAUTION! At the last fixture, the DMX signal has to be terminated with a terminator. Solder a 120Ω resistor between signal (-) and signal (+) into a XLR plug and plug it in the DMX output of the last fixture.

Diagram of connection of devices by DMX cable.FLASH-F7100443-LED-PAR-28x10W-
RGBW-Zoom-FIG \(5\)

IMPORTANT! The maximum number of devices connected in series via power cable is 5 pcs.

The connection is performed using a power cable with a powerCON connector (included). The device must be operated by qualified personnel.

CAUTION! In the case of cable damage do not attempt to repair. Replacement or repair can be made only on the manufacturer or by a person with appropriate permissions Using lamp, the change rate of power voltage should be within ±10%, if the voltage is too high, it will shorten the light’s life.

Voltage Specification.

Input Voltage Frequency Total Power
90-260[V] AC 50/60[Hz] 200[W]

Control Menu

MENU     DESCRIPTION

MODE

| ADDR| 001~XXX|  |  | DMX address setting

AUTO

|

IP1~8

| ALON/(AU-A)| SP_1 ~ SP_5

(Speed)

| Internal program (Alone)
MAST/(AU-M)| SP_1 ~ SP_5

(Speed)

| Auto run (Master)

SOUN

|

IP1~8

| ALON /(SO-A)|  | Sound control (Alone)
MAST /(SO-M)|  | Sound setting (Master)
CH| CH13/CH29/CH55/CH07| DMX Ch Mode setting

SET

| MIC| M-XX|  | Mic sensitivity setting
CURV| LINR/SQUE/IN-S/SCUR| Dimmer curve setting
LODA| ON/OFF|  | Reload data
VER| V1.00|  | Software version

CALI

| Code (Password: 088)| Input password
CH01~CH06| Calibration
REST| ON/OFF| Motor reset

MANU

| DIMM| 000-255|  | Dimmer set|

Manual channel Control

STRB| 000-255|  | Strobe set
RED| 000-255|  | Red set
GREE| 000-255|  | Green set
BLUE| 000-255|  | Blue set
WHIT| 000-255|  | White set
ZOOM| 000-255|  | Zoom set
COLO| 000-255|  | Color macro
CTO| 000-255|  | Color Temp
TEMP| TXXX|  |  |  | Current temperature

DMX CHART

DMX CH

Mode 1

| DMX CH

Mode 2

| DMX CH

Mode 3

| DMX CH

Mode 4

| DMX

Value

| Function
---|---|---|---|---|---
1| 1| 1| 1| 0-255| Dimmer (intensity from 0% to 100%)
 |  | 2|  | 0-255| Dimmer fine






2

| ****





2

| ****





3

| ****





2

|  | Shutter/ strobe
0-31| Shutter closed
32-63| Shutter open
64-95| Strobe-effect from slow to fast (1-25 Hz)
96-127| Shutter open
128-143| Opening pulse in sequences from slow to fast
144-159| Closing pulse in sequences from fast to slow
160-191| Shutter open
192-223| Random strobe-effect from slow to fast
224-255| Shutter open
3| 3| 4| 3| 0-255| Red (intensity from 0% to 100%)
 |  | 5|  | 0-255| Red fine
4| 4| 6| 4| 0-255| Green (intensity from 0% to 100%)
 |  | 7|  | 0-255| Green fine
DMX CH

Mode 1

| DMX CH

Mode 2

| DMX CH

Mode 3

| DMX CH

Mode 4

| DMX

Value

| Function
---|---|---|---|---|---
5| 5| 8| 5| 0-255| Blue (intensity from 0% to 100%)
 |  | 9|  | 0-255| Blue fine
6| 6| 10| 6| 0-255| White (intensity from 0% to 100%)
 |  | 11|  | 0-255| White fine
7| 7| 12| 7| 0-255| Zoom (from max. to min.beam angle)
 |  | 13| 4| 0-255| Zoom fine
 | 8| 14|  | 0-255| Red zone 1 (intensity from 0% to 100%)
 |  | 15|  | 0-255| Red zone 1 fine
 | 9| 16|  | 0-255| Green zone 1 (intensity from 0% to 100%)
 |  | 17|  | 0-255| Green zone 1 fine
 | 10| 18|  | 0-255| Blue zone 1 (intensity from 0% to 100%)
 |  | 19|  | 0-255| Blue zone 1 fine
 | 11| 20|  | 0-255| White zone 1 (intensity from 0% to 100%)
 |  | 21|  | 0-255| White zone 1 fine
 | 12| 22|  | 0-255| Red zone 2 (intensity from 0% to 100%)
 |  | 23|  | 0-255| Red zone 2 fine
 | 13| 24|  | 0-255| Green zone 2 (intensity from 0% to 100%)
 |  | 25|  | 0-255| Green zone 2 fine
 | 14| 26|  | 0-255| Blue zone 2 (intensity from 0% to 100%)
 |  | 27|  | 0-255| Blue zone 2 fine
 | 15| 28|  | 0-255| White zone 2 (intensity from 0% to 100%)
 |  | 29|  | 0-255| White zone 2 fine
 | 16| 30|  | 0-255| Red zone 3 (intensity from 0% to 100%)
 |  | 31|  | 0-255| Red zone 3 fine
 | 17| 32|  | 0-255| Green zone 3 (intensity from 0% to 100%)
 |  | 33|  | 0-255| Green zone 3 fine
 | 18| 34|  | 0-255| Blue zone 3 (intensity from 0% to 100%)
 |  | 35|  | 0-255| Blue zone 3 fine
 | 19| 36|  | 0-255| White zone 3 (intensity from 0% to 100%)
 |  | 37|  | 0-255| White zone 3 fine
 | 20| 38|  | 0-255| Red zone 4 (intensity from 0% to 100%)
 |  | 39|  | 0-255| Red zone 4 fine
 | 21| 40|  | 0-255| Green zone 4 (intensity from 0% to 100%)
 |  | 41|  | 0-255| Green zone 4 fine
 | 22| 42|  | 0-255| Blue zone 4 (intensity from 0% to 100%)
 |  | 43|  | 0-255| Blue zone 4 fine
 | 23| 44|  | 0-255| White zone 4 (intensity from 0% to 100%)
 |  | 45|  | 0-255| White zone 4 fine

FLASH-F7100443-LED-PAR-28x10W-RGBW-Zoom-FIG 7 FLASH-F7100443-LED-PAR-28x10W-RGBW-Zoom-FIG 8

FLASH-BUTRYM Sp.j.

Skarbimierzyce 18 · 72-002 Dołuje · POLAND

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FLASH User Manuals

Related Manuals