UNI-T LM585LD Laser Leveler User Manual
- June 12, 2024
- UNI-T
Table of Contents
LVIS8S5LD
Line Laser User Manual
Product introduction
1 | 360° horizontal glass window |
---|---|
2 | Vertical glass window (V1) |
3 | Vertical glass window (V2) |
4 | Vertical glass window (V3) |
5 | Vertical glass window (V4) |
6 | Protection lock |
7 | ON/OFF button |
8 | Battery pack |
9 | Charging port |
Safety instruction
Warning:
• Class Il Laser product
• Maximum output power: ≤ 1mW
• Wave length: 520nm|
---|---
Laser radiation:
• Do not stare at the laser beam.
• Do not point the laser to eyes.
• Do not use optical instrument.
Safety guideline **
**
Please carefully read and follow the safety instruction before use.
Warning
Please carefully read this manual and relevant safety information before
use.
Attention
Do not point the red or green laser beam to eyes when operating. Laser beam
may injure eyes.
Attention
Glasses as accessories are provided for some products, please pay attention
that these glasses are not safety glasses, they are only used to help users to
easily identify laser beam in strong light environment or when the laser
source is relatively far away from the users.
Do not observe laser beam directly by optical instrument or set the line laser at visual height.
- Do not disassemble the line laser without authorization, users do not need to repair any inside part of line laser.
- Do not make any alteration to the line laser, alteration may result in hazardous laser radiation.
- Do not use the line laser near children, and children are not allowed to use line laser.
- It is deemed as safe for users to expose eyes to Class
Il laser for no more than 2 seconds, users can blink to protect their eyes.
Operation
1 | 5/8 threaded connector |
---|---|
2 | Tune knob |
3 | Round water level |
4 | Foot screw |
5 | Screw hole |
Install lithium battery pack
Slide the switch to unlock/lock position to turn on/off the instrument. In
self-leveling/manual mode, LED indicator lights up green, the battery power
screen keeps displaying remaining power and stops displaying after turning off
the instrument for 5 seconds.
The instrument will conduct self-calibration after switching on, the
horizontal laser beam keeps lighting up after calibration, and then the line
laser enters self-leveling mode, within 3°+1°, the instrument will conduct
self-leveling, if beyond 3°+1°, the instrument will emit flashing beams and
alarm.
Press H button to turn on/off horizontal laser beam, press V button to turn
on/off vertical laser beams (Two horizontal/vertical laser beams can be used
together or separately).
When the instrument is ON, user can slide the lock switch to lock position to
turn off the switch.
Note:
This is to ensure that the instrument movement is locked before users turn off
the instrument.
Manual mode **
**
When the instrument is OFF, long press manual/pulse button for more than 3
seconds to turn on the instrument and it will enter manual mode. The angle of
laser beam can be set as needed. In self-leveling/manual mode, LED indicator
lights up red. Long press manual/pulse button again for more than 2 seconds,
the instrument will turn off.
Overrange sensing is OFF in manual mode and the laser beam flashes every 5
seconds to indicate that the manual mode is ON.
Note: In manual mode, the projected laser cannot be used as horizontal or vertical reference laser.
Pulse mode **
**
When the instrument is ON, short press manual/pulse button to enter pulse mode, the brightness of laser beam will decrease and the pulse indicator light up blue, the receiver can be used at this time. Short press manual/pulse button to exit pulse mode, and then the pulse indicator lights off.
Function description
The instrument can generate four vertical laser beams, one horizontal 360°
laser beam and one aligning point. When the instrument is ON, the logic
sequence defaults at vertical laser, horizontal laser and aligning point.
Short press H button to turn on/off horizontal laser beam and aligning point.
Short press V button to switch among vertical laser beams.
Specification
Laser type | LD green light |
---|---|
Laser wave length | 520nrn±5nm |
Laser power | 30mW |
Laser class | Class II |
Laser number | 8 beams |
Horizontal accuracy | ≤ ±3mm/10m (±60″) |
Vertical accuracy | ≤ ± 3mm/10m (± 60″) |
Laser width | <4mm/10m (Indoor light: 80-100Iux) |
Distance from ground | ≤20mm |
Emitting angle | Horizontal 360°, vertical 120° |
Working distance | 30m |
Working temperature | -10-40°C |
Storage temperature | -10-40°C |
Outdoor pulse | Pulse (5:5) mode |
Leveling time | ≤3 seconds |
Leveling range | 3° ± 1° |
Leveling type | Magnetic damping type, heavy bob type |
Battery type | Lithium battery pack (including 2 pieces of 18650 batteries) |
Battery capacity | 5200mAh with Type-C port |
Dimension | 138.3mm x 89.5mm x 136.4mm |
Working time | 4 hours |
Maintenance
- When the instrument is not in use, please turn it off and slide the lock switch to lock position.
- Do not short circuit the battery contact piece or put the batteries into fire.
- Do not put the batteries in high temperature environment or in places where sunlight shines directly.
- Clean the exterior plastic part with damp cloth, it is not recommended to wipe the instrument by solvents. Wipe the instrument with dry and soft cloth before storage.
- Store the instrument in soft case or plastic box when it is not in use.
- Do not put the instrument near household waste.
- Dispose of the lithium battery pack or discarded instruments according to WEEE directive or relevant directives.
Accessories
Instrument —————————— 1 piece
5200mAh lithium battery—————1 piece
Instruction manual———————-1 piece
Tripod mount—————————-1 piece
Lifting platform————————–1 piece
Type-C charging cable——————-1 piece
Adaptor————————————1 piece
Blow-molding box————————1 piece
UNI-TREND TECHNOLOGY (CHINA) CO., LTD.
No.6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial 2
Development Zone, Dongguan City, “4
Guangdong Province, China
P/N:110401109821X
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>