FLASH PROFESSIONAL P7100422 / P7100446 300W LED Par 64 Cob User Manual
- June 3, 2024
- FLASH PROFESSIONAL
Table of Contents
FLASH PROFESSIONAL P7100422 / P7100446 300W LED Par 64 Cob
INTRODUCTION
Thank you for purchasing LED PAR 64 COB 300W RGBWA+UV Mk2. For safety reasons and to ensure trouble-free operation, carefully read the instructions.
SAFETY INFORMATION
- Installation should be done by qualified personnel in order to minimize the risk of accidental electric shock
- Disconnect the power supply before installation.
- Before connecting the unit to the mains, make sure it is not damaged mechanically. If you notice any signs of damage you should contact your dealer immediately. Do not connect the device to the mains.
- Do not use the device in high humidity conditions and at temperatures above 40° C
- The device must be installed on stable structures
- Always use steel security cable to attach the device to a stable structure
- Do not connect power supply to more than 3 devices in series.
SECURITY PRINCIPLES RELATING TO UV RADIATION
- A device emitting UV light can be installed and used only by personnel trained in the knowledge of the hazards when using UV light sources, methods to counteract these threats and the rules of safe use of such sources (particularly the high power sources of UV light). The manufacturer is not responsible for damages resulting from improper use of the device.
- The device must be installed at a distance from the illuminated people, which ensures a safe staying in a room without compromising the health of the negative effects of UV radiation. The device must be installed in a way as to prevent illumination directly on the skin, face or eyes. The room can be illuminated only by light reflected from the surface (walls, ceilings) – never through direct referral of the reflector in the direction of people in the room.
Threats to health, effects of exposure to UV radiation
An excessive effect of UV radiation on the body often has no immediate
symptoms. Symptoms of overexposure, including the various stages of burns or
Photokeratitis, usually occur from 4 to 24 hours after the exposure. There is
a possibility that the level of UV intensity emitted by the device
significantly exceeds the naturally occurring level (especially at a short
distance from the light source).
- SKIN: UV radiation can cause erythema (sunburn) within the exposed skin. This involves redness and/or ulcerations, which can have a different intensity. In the case of improper use of the device effects of UV radiation on the skin can occur even after a few seconds of exposure. Symptoms may be different depending on the genetic background. People with pale to fair skin are more prone to sunburn. Some medications (eg. Contraception), and some food products (eg. celery root, figs) may increase sensitivity to UV radiation. Chronic exposure to UV radiation causes premature skin aging, wrinkles and skin cancer.
- EYES: UV radiation is dangerous for the eyes, not only for looking directly into the light source, but also when eyes are exposed to the UV rays reflected from surfaces (reflectors with high power). Exposure of the eye to UV radiation can cause corneal damage and Photokeratitis (painful inflammation of the eye caused by changes induced by UV radiation to the cornea). One of the symptoms may be “feeling of sand in the eyes” which may persist for several days. In extreme cases, it can cause damage to the lens of the eye that can lead to cataracts.
- OTHER THREATS: In addition to significant hazards for the eyes and skin, the impact of UV radiation on substances in the air can lead to the generation of toxic compounds that may be harmful to people in the room.
WARNING! When installing and using the device you should provide appropriate conditions, which prevents the occurrence of risks described above.
Personal protective equipment
- EYE PROTECTION: Eye protection must be worn at all case where there is possibility of exposure to UV radiation. Glasses should be consistent with ANSI-Z87. Normal eye protection, prescription glasses or contact lenses offer little or no protection. Glasses providing adequate eye protection are marked Z87.1
- PROTECTIVE MASK: In some cases, in addition to safety glasses or goggles, a full face protection should be worn. Masks protect the entire face, especially under the chin, where serious skin burns may occur, even in the short time exposure. Full face protection is recommended in case of long term exposure to UV radiation.
- PROTECTIVE CLOTHING: In some cases it is required to wear protective clothing to prevent burns resulting from exposure of the skin to UV rays
PRODUCT INFORMATION
The device is equipped with high-quality, bright COB LED with Red, Green,
Blue, White and additional Amber and UV chips. Unique design, high quality and
high durability make this device a great tool for both power users and those,
who value simplicity and reliability.
The ergonomic double bracket (included) facilitates the use of the device in
any condition. In order to expand the range of mounting options, the holder
has an additional mounting holes.
The electronics is made of high quality components and offers several features
such as:
Features
- 16-bit dimming resolution
- Various dimming curves for smooth dimming in 8-bit mode
- Dim delay (light bulb simulation)
- Full DMX signal regeneration
- Electronic protection against overheating
- THEATRE or DISCO cooling volume modes.
- Permanent color correction
- Native support for optional wireless DMX module
Specification
- Power consumption: 300W
- Power supply voltage: 100 – 245V
- Voltage frequency: 50/60Hz
- Diode type: COB 6in1
- Number of diodes: 1
- Diode power: 300W
- Display: Color LCD 1,8”
- Color: RGBWA + UV
- Beam angle (min): 37°
- Beam angle (max): 37°
- Dimming: Linear: 0 – 100%
- Number of DMX channels:
- DMX standard: DMX 512
- Control interface: 4 buttons
- Operating modes: DMX512, Auto, Sound-controlled, Manual color, Master
- Features: 16-bit dimming, DMX Signal regeneration, Electronic protection against overheating
- AC IN: powerCON
- AC OUT: powerCON
- DMX IN: XLR – 3 pin
- DMX OUT: XLR – 3 pin
- IP Rating: IP20
- Housing made: ABS
- Cooling: Active
- Height [cm]: 27
- Width [cm]: 30
- Depth [cm]: 13
- Weight [kg]: 3,6
- Weight with packaging [kg]: 4,4
- Set includes: Power cord, Double bracket, Barn Doors
Flash Professional LED PAR 6in1 RGBW+UV Mk2
INSTALLATION
After removing the packaging, check if the device was not damaged during
transport. Before connecting to the mains, make sure that the device is
securely mounted. The manufacturer is not responsible for damage caused by
unstable mounting.
CAUTION! Always use steel security cable to attach the device to a stable
structure.
Ensure proper connection to the mains and proper grounding. Make sure that the
electrical parameters are consistent with device requirements. All activities,
including connecting the device to the mains must be performed by qualified
personnel.
CONNECTIONS
The device is equipped with the following interfaces:
- DMX (in/out): XLR 3-pin socket
- Power (in/out): powerCON socket
Connecting DMX signal
The connection is performed using cable with XLR-female -> XLR-Male plugs.
Voltage specification
Input Voltage | Total Power | Frequency |
---|---|---|
100~245V | 300W | 50/60Hz |
Connecting power supply
The connection is performed using power cable with PowerCon connector
(included).
The device must be operated by qualified personnel. Make sure that the power
grid supply parameters are consistent with device parameters and limitations
are not exceeded.
CAUTION! In the case of cable damage do not attempt to repair.
Replacement or repair can be made only on the manufacturer or by a person with
appropriate permissions.
Maximum number of devices connected in series: 3
OPERATION MANUAL
Control panel
The control panel is equipped with LCD display and 4 control buttons with the
following functions:
- ESC – go back from the selected options, go to upper menu, cancel changes
- DOWN – choose option, edit parameter
- UP – choose option, edit parameter
- ENTER edit selected option, confirm changes
Master / slave
To achieve desired effects with Master/slave mode set the first device in DMX
chain as Master (MASTER function is [ON] ). Set the following devices to DMX
mode -> Classic 8 -> CH 001
DMX channel list
Standard 8 [8CH]
Channel| Function| Effect
CH 1| Dimmer| 0-255: 0-100%
CH 2| Strobe| 0-10: No Function
11-255: Strobe 1-20Hz
CH 3| Red| 0-255: 0-100%
CH 4| Green| 0-255: 0-100%
CH 5| Blue| 0-255: 0-100%
CH 6| White| 0-255: 0-100%
CH 7| Amber| 0-255: 0-100%
CH 8| UV| 0-255: 0-100%
Pro 8 [8CH]
Channel| Function| Effect
CH 1| Red| 0-255: 0-100%
CH 2| Green| 0-255: 0-100%
CH 3| Blue| 0-255: 0-100%
CH 4| White| 0-255: 0-100%
CH 5| Amber| 0-255: 0-100%
CH 6| UV| 0-255: 0-100%
CH 7| Dimmer| 0-255: 0-100%
CH 8| Strobe| 0-10: no function
11-255: strobe 1-20Hz
Pro 9 [9CH] | ||
---|---|---|
Channel | Function | Effect |
CH 1 | Red | 0-255: 0-100% |
CH 2 | Green | 0-255: 0-100% |
CH 3 | Blue | 0-255: 0-100% |
--- | --- | --- |
CH 4 | White | 0-255: 0-100% |
CH 5 | Amber | 0-255: 0-100% |
CH 6 | UV | 0-255: 0-100% |
CH 7 | Dimmer | 0-255: 0-100% |
CH 8 | Dimmer fine | 0-255: fine adjustment (16-bit) |
CH 9 | Strobe | 0-10: no Function |
11-255: strobe 1-20Hz
RGB [3CH]
Channel| Function| Effect
CH 1| Red| 0-255: 0-100%
CH 2| Green| 0-255: 0-100%
CH 3| Blue| 0-255: 0-100%
RGBWA+UV [6CH]
Channel| Function| Effect
CH 1| Red| 0-255: 0-100%
CH 2| Green| 0-255: 0-100%
CH 3| Blue| 0-255: 0-100%
CH 4| White| 0-255: 0-100%
CH 5| Amber| 0-255: 0-100%
CH 6| UV| 0-255: 0-100%
RGB 16-bit [6CH]
Channel| Function| Effect
CH 1| Red| 0-255: 0-100%
CH 2| Red fine| 0-255: fine adjustment
CH 3| Green| 0-255: 0-100%
CH 4| Green fine| 0-255: fine adjustment
CH 5| Blue| 0-255: 0-100%
CH 6| Blue fine| 0-255: fine adjustment
RGBWA+UV 16-bit [12CH]
Channel| Function| Effect
CH 1| Red| 0-255: 0-100%
CH 2| Red fine| 0-255: fine adjustment
CH 3| Green| 0-255: 0-100%
CH 4| Green fine| 0-255: fine adjustment
CH 5| Blue| 0-255: 0-100%
CH 6| Blue fine| 0-255: fine adjustment
CH 7| White| 0-255: 0-100%
CH 8| White fine| 0-255: fine adjustment
CH 9| Amber| 0-255: 0-100%
CH 10| Amber fine| 0-255: fine adjustment
CH 11| UV| 0-255: 0-100%
CH 12| UV fine| 0-255: fine adjustment
Read User Manual Online (PDF format)