XPOWER AP-1500D Mega Air Purification Owner’s Manual

June 4, 2024
XPOWER

Air Scrubber Owner’s ManualXPOWER AP-1500D Mega Air
Purification Model:
AP-1500D Series, AP-1800D Series, AP-2500D Series (115V~, 60Hz)
Read and save these instructionswww.xpower.com
1-(855)-855- 8868
 info@xpower.com

Safety Instructions

WARNING – READ AND SAVE THIS INSTRUCTION BEFORE USING THIS PRODUCT.
The user of electrical products may create hazards that include but are not limited to injury, fire, and electrical shock. Failure to follow these instructions may damage and/or impair its operation and void the warranty.

  • Before operating, remove all packaging material and check for any damage that may have occurred during shipping or any missing items.
  • Check the power supply to ensure it matches the appliance’s specification.
  • DO NOT operate any fan with a damaged cord or plug. Discard the fan or return it to an authorized service facility for examination and/or repair.
  • Use only on GFCI-protected receptacles. Please contact a qualified electrician for verification and/or installation of a GFCI receptacle if necessary.
  • DO NOT run cord under carpeting. DO NOT cover the cord with throw rugs, runners, or similar coverings. DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
  • To reduce the risk of fire or electric shock, DO NOT use this machine with any solid-state speed control device.
  • DO NOT touch this appliance or the plug with wet hands or while standing in water.
  • DO NOT operate the appliance in any pooled water.
  • DO NOT use the product in areas where gasoline, paint, or other flammable goods and objects are used or stored.
  • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the appliance and void the warranty.
  • DO NOT cover the air inlet or outlet on the appliance.
  • DO NOT direct the airflow at human faces or bodies.
  • DO NOT allow children to play with this appliance.
  • AUTOMATICALLY OPERATED DEVICE – To reduce the risk of injury, disconnect from the power supply before servicing.
  • Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, DO NOT pull the cord directly.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions of this appliance, as this may cause danger and void the warranty.
  • If the appliance is damaged or it malfunctions, DO NOT continue to use it. Unplug the product from the electrical outlet. Refer to the troubleshooting guide or contact XPOWER.
  • Store in a dry area, away from exposure to sunlight, extreme temperature, and humidity, or other extreme environments, when not in use.
  • An electronic instruction manual can be obtained through the website: www.xpower.com.

Parts Description

Machine

XPOWER AP-1500D Mega Air Purification - fig1

(1) Inlet Grille Cover Screw
(2) Inlet Grille Cover
(3) Handle Screw
(4) Rubber Pad
(5) Motor Inlet Grille Cover
(6) Time Meter*
(7) Motor Housing Fixator Assembly
(8) Motor Fixator
(9) Motor Right Housing
(10) Heat Insulation Plate
(11) Motor
(12) Bushing| (13) Fan
(14) Motor Left Housing
(15) Motor Control Circuit Board Assembly
(16) Rivet Nut
(17) Filter Fixator
(18) Flange Nut
(19) Handle Cover
(20) Handle Tube
(21) Housing
(22) Air Quality Sensor Cover
(23) Air Quality Sensor
(24) Power Switch| (25) Speed Switch Knob
(26) Control Panel
(27) Speed Switch Circuit Board
(28) Circuit Breaker
(29) Air Quality Sensor Box
(30) Pressure Gauge
(31) Power Cord Container Cover
(32) Power Cord
(33) Wheel Assembly
(34) Wheel Chassis
(35) Handle Screw Sleeve
---|---|---

Filters

XPOWER AP-1500D Mega Air Purification - fig2

Filters (Continued)

MODEL NUMBER AP-1500D Series AP-1800D Series AP-2500D Series
First Stage Filter NFS16 RP20 RP24
Second Stage Filter PF16 PF19 PF23
Third Stage Filter CF35 CF35-490 CF50-595 (Optional)
Fourth Stage Filter HEPA300-406PV HEPA300-490PV HEPA300-PV

Items Included

XPOWER AP-1500D Mega Air Purification - fig3

Air Scrubber Introduction

  • XPOWER’s unique and highly innovative Air Scrubbers create a fresh and clean environment for various purposes.
  • With a specially designed powerful motor, XPOWER Air Scrubbers are able to provide suction in even difficult areas.
  • The included filtration system can capture a wide range of compounds and prevents organism migration from location to location.

Installation and Operation Guide

Remove Filter Package (If Any)
Remove the packages of the filter before the first usage.

Zero Setting

  • The accuracy of the pressure gauge might be affected by transportation.
  • Before the first usage, you should zero the pressure gauge in order to ensure the accuracy of the measurement.

XPOWER AP-1500D Mega Air Purification - fig5

  • Use a straight screwdriver to adjust the zero setting screw on the pressure gauge, until the pointer stays in the middle of the zero sector.

Installing the Handle

  1. Screw off the hex screw with a hex screwdriver on the inlet grill cover.
  2. Take out the inlet grill cover.
  3. Put the screws through the holes on the handle and the back of the machine housing.
  4. Fasten the screws with the nuts from the inner surface of the machine.

Extension Setup (Optional)

XPOWER AP-1500D Mega Air Purification - fig7

Selecting a Location (Important)

  • Enclosed Area: For optimal efficiency and longer filter lifespan, the Air Scrubber should be operated in an enclosed area. Keep all doors, windows and other outside entrances to the room closed.

  • Air Circulation: It’s suggested to have a constant efficient air circulation inside your working area.

  • Environment Humidity: For optimal efficiency and higher filter lifespan, the Air Scrubber should not be operated in an environment with a high relative humidity level.
    High humidity levels could cause blockage and damage to filters.

  • Power Cord: The power cord has a length of 25 feet (7.6 meters). Select a location where the power cord can reach the power source.

  • Inlet and Outlet Orientation: Also pay attention to the orientation of the air inlet and air outlet. Make sure the airflow won’t influence any object nearby the Air Scrubber.

  • IMPORTANT: The effectiveness of the Air Scrubber can be influenced by different factors. You may also find that installing multiple Air Scrubbers may be required for larger enclosed areas.

Control Panel

XPOWER AP-1500D Mega Air Purification - fig8

Air Quality Monitor

  • When this monitor blinks, it indicates the Air Quality Sensor is now preparing for detection.
  • The digital display will show the concentration of fine particulate matter (PM₂₅) in the environment in μg/m³.
  • The index light will indicate the air quality category of the environment. According to the Air Quality Index developed by the United States Environmental Protection Agency (EPA), the index light corresponds to different levels of health concern as below:
Index Light Levels of Health Concern according to the AQI by EPA
Green / Good Good
Orange (Yellow) /Moderate Moderate or, Unhealthy for Sensitive Groups
Red / Poor Unhealthy, Very Unhealthy, or Hazardous

Time Meter (For Model AP-1500DM, AP-1800DM and AP-2500DM Only)

  • The time meter contains 3 meters. Press the setting button to switch the meters.

  • The master meter shows the total running time from the first usage to the current moment. The value of the master meter can’t be reset.

  • The value of meter 1 and meter 2 can be reset. Press the setting button for up to 5 seconds to reset the value.

  • When the fan turns on, the activity indicator will blink. The running time starts to count.
    When the fan is off, the activity indicator will stay illuminated.

  • When the value exceeds 9999.9 hours, it will start over from 0 again.

Circuit Breaker
If the machine stops working, press the RESET BUTTON to reset the machine.

Power Switch

  • Turn to the “O” position to switch the power OFF. Turn to the “I” position to switch the power ON.

Speed Switch

  • Turn to the “OFF” position to switch the fan OFF. Turn clock-wisely to any position between “MAX” and “MIN” to switch the fan ON.
  • You can adjust to any desired speed variably. “MAX” is the highest speed and “MIN” is the lowest speed.

Pressure Gauge
This measures the negative pressure between the motor inlet and filter outlet.

  • Before the first usage, you should zero the pressure gauge in order to ensure the accuracy of the measurement. (See Page 6: Zero Setting)
  • Load all the filters, switch the power on, and turn to the highest speed. If the negative pressure exceeds the values below, it indicates that the filters might have exceeded the maximum capacity of particles, and the filtration efficiency, as well as the airflow, have diminished. You should check, clean, or replace the filters. (See Page 12: Filter Maintenance)
  • Even if the pressure gauge shows negative pressure is still lower than the values below, it’s suggested to check and replace the filters every 6 months. (See Page 12: Filter Maintenance)

| AP-1500D Series| AP-1800D Series| AP-2500D Series
---|---|---|---
Without Carbon Filter| 270 Pa.| 370 Pa.| 340 Pa.
With Carbon Filter| 350 Pa.| 500 Pa.| 500 Pa.

Transportation

XPOWER AP-1500D Mega Air Purification - fig9

Transport with Trolley Handle

  • Press down the trolley handle to tilt up the air scrubber on the wheels.
  • Push forward to transport with the trolley handle.

User Maintenance Instructions

Frequent maintenance is recommended on this appliance. Failure to follow the maintenance instructions may cause the failure of the appliance and void the warranty.
Before performing any maintenance or cleaning, always disconnect the Air Scrubber from its power source.

Machine Maintenance

  • When not in use, unplug, and uninstall power cords and all the extensions. Store the appliance in a dry and cool indoor place. Make sure it’s out of reach of children.
  • Use a damp cloth to wipe the surface of the housing. Do not clean the unit with water directly.
  • Check if the grille covers are clean. Remove dirt or any other objects that could block the air inlet and air outlet.

XPOWER AP-1500D Mega Air Purification - fig10

Organize the Cord

  • The power cord can be stored in the power cord container at the rear of the air scrubber.

Filter Maintenance
To ensure the best filtration efficiency and to prevent secondary pollution from used filters, you should replace or clean the filters frequently, or when the filter cleans/changes light illuminates. Please follow the instructions below.

Unload the filters (See Also Page 3: Parts Description)

XPOWER AP-1500D Mega Air Purification - fig11

  • Screw off the screw on the inlet grill cover and take out the inlet grill cover.
  • Screw off the 4 screws on the sides, and release the filter fixator.
  • Then you could unload the filters from the top.

Clean the filters (See Also Page 3: Parts Description)

  • *Rigid Polyester Filters:** These filters are washable with water. Use a vacuum or clean cloth to remove loose debris. And then further clean the filter with water. Use a cloth to remove the water on the filter and dry it naturally in the air.
  • Pleated Media Filters: This filter is not washable. Use a vacuum to remove loose debris. If the filter change light still illuminates, you might need to replace the filter.
  • *HEPA Filters:** This filter is not washable or reusable. Highly concentrated particles are captured by the HEPA filter and cleaning this filter can be hazardous to human health and contaminate the nearby environment. You must replace the filter if all the other filters are clean however the pressure gauge still shows a high negative pressure value…

Filter storage

  • When not in use for a long time, you should store the filter separately from the machine.
  • Always clean the filters before storage. Place the filters in a sealed plastic bag and store them in a dry and cool indoor place.

Replace the filters periodically

  • Even if the pressure gauge shows negative pressure is still lower than the values below, it’s suggested to check and replace the filters every 6 months.
  • Stored or unused filters are also suggested to check and replace the filters every 6 months.

WARNING: DISPOSAL OF FILTERS NO LONGER IN USE
The particles captured by a used filter can cause adverse human health effects and contaminate the nearby environment once the filter is exposed to the open air. Adequate personal protection equipment (PPE) is required during the whole process, for example, industry-approved masks, eye protectors, gloves, and coveralls. You should place the used filters in a sealed plastic bag before disposing of them. Follow local disposal regulations.

Reload the filters
To ensure the best efficiency and lifespan, each filter must be reloaded in the correct position, sequence and orientation.

XPOWER AP-1500D Mega Air Purification - fig12

Tips:

  • On one of the sides of each filter, there is a label with an arrow showing the airflow direction.

  • When placing the filter, the side with the label should face up. The arrow on the label should point to the exhaust.

  • All replacement filters are available on www.xpower.com.

Troubleshooting Guide

PROBLEM

| POSSIBLE CAUSE|

SOLUTION

---|---|---
Air Scrubber does not start|  No electricity.| Check for power supply.
The power cord is not properly plugged in.| Remove and reconnect the power cord.
 The circuit breaker on the additional electrical receptacle
(Daisy chain) trips.| Remove all appliances on the additional electrical receptacle and press the circuit reset button.
Unit runs but no or very low air movement| The air outlet is blocked.| Remove blockage.
Filters are fully loaded. The
filter clean/change light
illuminates.| Clean or replace the loaded filters. (See Page 12: Filter
Maintenance)
The unit runs and stops automatically and repeatedly| The input voltage is too low.
The voltage protection within the unit triggers.| Check for power supply. Try to plug in another power outlet. Try to use an extension cord that is 16 AWG or larger and less than 25 feet.
The additional electrical receptacle has no power| The circuit breaker trips.| Press the circuit reset button.

If troubleshooting does not resolve your problem, please contact XPOWER or other parties authorized by XPOWER for further instructions.

Technical Specification

Machine Specification

MODEL  UMBER AP-1500D Series AP-1800D Series AP-2500D Series
Voltage/Frequency 115 V∼, 60 Hz
Amperage 1.5 A 3.5 A  8.0 A
Rated Airflow 700 CFM 1100 CFM  1800 CFM
Speed Control Variable Speeds
Cord Length 13 ft. /4.0 m  25 ft. / 7.6 m

Unit Dimension
(L) x (W) x (H)| 49.3 x 55.5 x 91 in. /
19.4 x 21.9 x 35.8 cm| 57.4 x 63.9 x 94.6 in. /
22.6 x 25.2 x37.2 cm|  29.4 x 26.7 x 38.8 in.
/ 74.8 x 67.8 x 98.6cm
Unit Weight| 45.9 lbs / 20.8 kg| 65.7 lbs / 29.8 kg|  95.1 lbs. / 43.13 kg

Filter Specification

FILTER MODEL
NUMBER

| Type of Filter| Size| Thickness|

Function

---|---|---|---|---
NFS16| Nylon Mesh Filter| 16 x 16 in.| | Primary filtration for visible and coarse particles.
RP20| Rigid Polyester Filter| 20 x 20 in.| 1 in.
RP24| 24×24 in.| tin.
PF16| Pleated Media Filter| 16 x 16 in.| 0.8 in.| Medium filtration for fine dust.
PF19| 19 x 19 in.| 1.4 in.
PF23| 23 x 23 in.| 1.8 in.
CF35| Carbon Filter| 16 x 16 in.| 1.4 in.|  Filtration for gases.
CF35-490| 19 x 19 in.| 14 in.
CF35-595| 23 x 23 in.| 14 in.
HEPA300-406PV| Plastic V-Shaped HEPA Filter| 16 x 16 in.| 11.5 in.| Final filtration for microparticles.
HEPA300-490PV| 19 x 19 in.| 11.5 in.
HEPA300-PV| 23 x 23 in.| 11.5 in.

XPOWER Limited Warranty (USA)

1 YEAR LIMITED WARRANTY
XPOWER-branded products purchased in the U.S. from authorized distributors include a 1-year limited warranty. Contact XPOWER to confirm warranty information about your product(s).
This limited warranty covers defects in materials and workmanship in your XPOWERbranded products, purchased in the U.S.ONLY. Local warranty policy (if any) in your country will cover products purchased outside the U.S.!

IMPORTANT:

  1. Please finish the online warranty registration before usage. Visit www.xpower.com/service-support/warranty-registration.
  2. This Limited Warranty applies with its own timeliness. Contact XPOWER or visit www.xpower.com for more information.

Items mentioned but not limited to below are not covered by warranty:

  1. Power cord, filters, or any other components are considered “consumable parts” by XPOWER.
  2. Normal wear and tear.
  3. Problems that result, directly or indirectly, at XPOWER’s sole discretion, from:
  4. External causes such as accidents, abuse, misuse, or problems with electrical power supply.
  5. Disassembling, servicing, or modification not authorized by XPOWER.
  6. Usage that is not accordant with product instructions stated in the Owner’s Manual.
  7. Failure to follow the product instructions or lack of necessary maintenance stated in the Owner’s Manual.

Before contacting XPOWER, please try one or more of the following:

  1. Consult this Owner’s Manual and follow the instructions of the troubleshooting guide.
  2. Access www.xpower.com for more advice and information that could be helpful to address your problems.

If you need additional assistance from XPOWER, please:

  1. Email info@xpower.com.
  2. Call XPOWER U.S. Customer Service Department at 855-855-8868 or other numbers provided on www.xpower.com.
  3. Visit XPOWER U.S. Head Office at 668 S. 6th Ave., City of Industry, CA 91746 USA, or the most current address provided on www.xpower.com.

Please also have your original proof of purchase and the serial number(s) of your product(s) ready when you contact XPOWER.

If you are instructed to return the unit for service or replacement, please:

  1. Request a RMA (Return-Merchandise-Authorization) number.
  2. Use the original or an equivalent packaging, prepay shipping charges at your own expense to the address provided by XPOWER, with the RMA number on the shipping label or the packaging.
  3. Include all the original parts and components.

XPOWER will inspect, assess and advise the repairs needed and applicable cost if any. For products under warranty, we will pay to ship the repaired or replaced product(s) to you if you use an address within the Contiguous United States. Otherwise, we will ship the product(s) to you at your own expense.

XPOWER Manufacture, INC.
668 S. 6th Ave.,
City of Industry, CA 91746 USA
www.xpower.com
1-(855)-855-8868
info@xpower.com
Read and save these instructions
Index: NA-1-A40
Edition: 1.3.Final

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals