xpower X-39AR Air Mover Axial Fan Owner’s Manual

June 5, 2024
XPOWER

xpower X 39AR Air Mover Axial Fan - iconAxial Fan Owner’s Manual
Model: X-39AR, X-47ATR (115V 60HZ)
Read and save these instructions before use
www.xpower.com 
1-(855)-855-8868 |info@xpower.com 

Safety Instructions

WARNING – READ AND SAVE THIS INSTRUCTION BEFORE USING THIS PRODUCT.
The user of electrical products may create hazards that include but are not limited to injury, fire, and electrical shock. Failure to follow these instructions may damage and/or impair its operation and void the warranty.

  • Before operating, remove all packaging material and check for any damage that may have occurred during shipping or any missing items.
  • Check the household power supply to ensure it matches the appliance’s specifications.
  • DO NOT operate any fan with a damaged cord or plug. Discard fan or return it to an authorized service facility for examination and/or repair.
  • Use only on GFCI-protected receptacles. Please contact a qualified electrician for verification and/or installation of a GFCI receptacle if necessary.
  • DO NOT run cord under carpeting. DO NOT cover the cord with throw rugs, runners, or similar coverings. DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
  • Suitable for use with solid-state speed control.
  • DO NOT touch this appliance or the plug with wet hands or while standing in water.
  • DO NOT operate the appliance in any pooled water.
  • DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are used or stored.
  • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the appliance and void the warranty.
  • DO NOT cover the air inlet or outlet on the appliance.
  • DO NOT direct the airflow at human faces or bodies.
  • DO NOT allow children to play with this appliance.
  • AUTOMATICALLY OPERATED DEVICE – To reduce the risk of injury, disconnect from the power supply before servicing.
  • Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, DO NOT pull the cord directly.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions of this appliance, as this may cause danger and void the warranty.
  • If the appliance is damaged or it malfunctions, DO NOT continue to use it. Unplug the product from the electrical outlet. Refer to the troubleshooting guide or contact XPOWER.
  • Store in a dry area, away from exposure to sunlight, extreme temperature, and humidity, or other extreme environments, when not in use.
  • DO NOT stack more than five units of this appliance.
  • An electronic instruction manual can be obtained through the manufacturer’s website www.xpower.com.

Items Included

xpower X 39AR Air Mover Axial Fan - fig

  • For model X-39AR only.
    ** For model X-47ATR only.

Parts Description

xpower X 39AR Air Mover Axial Fan - fig 1

(1) Front Grille Cover
(2) Motor
(3) Housing
(4) Additional Electrical Receptacle
(5) Capacitor| (6) Housing Handle
(7) Switch Plate
(8) Rack Handle
(9) Rubber Washer
(10) Rack| (11) Circuit Board
(12) Fan
(13) Rear-End Cover
(14) Rear Grille Cover
(15) Power Cord
---|---|---

Axial Fan Introduction

  • XPOWER Axial Fans are designed to offer efficient air circulation and ventilation with its high and long-distance focused airflow.
  • It’s perfect for air circulation and ventilation in janitorial/ sanitation jobs, water damage restoration and more.

Installation and Operation Guide

**Installing the Rack***xpower X 39AR Air Mover Axial Fan - fig
5

  1. Fit both rubber washers onto bolts on both sides of unit.
  2. Align the rack onto the axial fan.
  3. Fasten the connection with the rack handle.
  • For model X-39AR only.

Switch Plate

Variable Speed Switch

  • Turn to the “OFF” position to switch the Axial Fan OFF. Turn clock-wisely to any position between “MAX” and “LOW” to switch the Axial Fan ON.
  • You can adjust to any desired speed variably. “MAX” is the highest speed and “LOW” is the lowest speed.

Installation and Operation Guide (Continued)
Additional Electrical Receptacle (Daisy Chain)

  • Other appliances can be plugged in the additional electrical receptacles and work whether the Axial Fan is on or off. However, the total amperage must be lower than the
    amperage instructed. Different models may have varying instructions.

  • If the Axial Fan or the plugged-in appliance stops working, press the RESET BUTTON to reset the circuit.

**Timer Switch***

  • Turn clockwise to set a timer for minutes to count down to an automatic stop.
  • The timer can be set for up to 180 minutes (3 hours).
  • When the timer reaches the “0” position, the unit stops working. In the “ON” position, it will work constantly.
    * For model X-47ATR only.

Installation and Operation Guide (Continued)
Adjust Operation Positionxpower X 39AR Air Mover Axial Fan - Fan
features

  • The Axial Fan features 360° Rotation. Tilt the Axial Fan to desired angle and screw on rack handles to secure the fan’s position.

xpower X 39AR Air Mover Axial Fan - Axial

**Use without Rack***

  • Uninstall the rack and place the Axial Fan on a level surface.
  • For model X-47ATR only.

Installation and Operation Guide (Continued)
Transportation

Lift with Handle

  • Lift the Axial Fan with the handle on the top.

User Maintenance Instructions

Frequent maintenance is recommended on this appliance. Failure to follow the maintenance instructions may cause failure of the appliance and void the warranty.

  • When not in use, unplug and store the appliance in a dry and cool indoor place. Make sure it’s out of reach of children.
  • Before performing any maintenance or cleaning, always disconnect the Axial Fan from its power source.
  • Use a damp cloth to wipe the surface of the housing. Do not clean the unit with water directly.
  • Check if the grille covers are clean. Remove dirt or any other objects that could block the air inlet and air outlet.

User Maintenance Instructions (Continued)

Fasten the Rack Handles

  • To prevent possible injury, when you finish using this appliance, please position the Axial Fan UPRIGHT.
  • Fasten the rack handle to lock the position of the Axial Fan.

xpower X 39AR Air Mover Axial Fan - Power Organize the Power Cord

  • Wrap the power cord around the housing.
  • Clip the cord to the cord clip on the plug shown above.

User Maintenance Instructions(Continued)

Stack Multiple Units

  • Stack the Axial Fans on the sides. Align the air inlets of both Axial Fans.

WARNING

  • Do not stack more than five units of this appliance.
  • Stacking function is not secure during transportation. !

Troubleshooting Guide

PROBLEM POSSIBLE CAUSE SOLUTION

The axial fan does not start

| No electricity.| Check for power supply.
The power cord is not properly plugged in.| Remove and reconnect the power cord.
The circuit breaker on the additional electrical receptacle (Daisy chain) jumps.| Remove all appliances on the additional electrical receptacle and press “Reset”. op
The timer switch is set to “0” position.*| Set the timer switch to the “ON” position.
Unit runs but the speed is abnormal| The Air inlet or air outlet is blocked.| Remove blockage.

  • The timer function does not apply to all models mentioned in this manual.
    If troubleshooting does not resolve your problem, please contact XPOWER or other parties authorized by XPOWER for further instructions.

Technical Specification

MODEL NUMBER X-39AR X-47ATR
Voltage/Frequency 115 V~60 Hz
Amperage 1.6 A 2.8 A
Motor Power 1/4 HP 1/3 HP
Rated Airflow 2100 CFM 3600 CFM
Speed Control Variable Speeds
Timer N/A 3 hours (OFF)
Additional Electrical Receptacles (Daisy Chain) Yes
Cord Length 20 ft. / 6.1 m
Housing ABS

Unit Dimension
(L) x (W) x (H)| 18.6 x 9.4 x 19.2 in. /
47.2 x 23.9 x 48.8 cm| 21.9 x 9.8 x 22.5 in. /
55.6 x 24.9 x 57.1 cm
Unit Weight| 16.5 lbs. / 7.5 kg| 22.2 lbs. / 10.1 kg
Safety Certification| ETL/C-ETL

If your product(s) is not listed above, please visit www.xpower.com for more information.

XPOWER Limited Warranty (USA)

  1. YEAR LIMITED WARRANTY
    XPOWER-branded products purchased in the U.S. from authorized distributors include a 1-year limited warranty. Contact XPOWER to confirm warranty information about your product(s).
    This limited warranty covers defects in materials and workmanship in your XPOWERbranded products, purchased in the U.S. ONLY. Local warranty policy (if any) in your country will cover products purchased outside the U.S.!

IMPORTANT:
(1) Please finish the online warranty registration before usage. Visit www.xpower.com/service-support/warranty-registration.
(2) This Limited Warranty applies with its own timeliness. Contact XPOWER or visit www.xpower.com for more information.
Items mentioned but not limited to below are not covered by warranty:
(1) Power cord, filters or any other components considered as a “consumable parts” by XPOWER.
( 2) Normal wear and tear.
(3) Problems that result, directly or indirectly, at XPOWER’s sole discretion, from:
(3.1) External causes such as accident, abuse, misuse or problems with electrical power supply.
(3.2) Disassembling, servicing or modification not authorized by XPOWER.
(3.3) Usage that is not accordant with product instructions stated in the Owner’s Manual.
(3.4) Failure to follow the product instructions or lack of necessary maintenance stated in the Owner’s Manual.
Before contacting XPOWER, please try one or more of the following:
(1) Consult this Owner’s Manual and follow the instructions of the troubleshooting guide.
(2) Access www.xpower.com for more advice and information that could be helpful to address your problems.
If you need additional assistance from XPOWER, please:

  1. Email info@xpower.com.
  2. Call XPOWER U.S. Customer Service Department at 855-855-8868 or other numbers provided on www.xpower.com.
  3. Visit XPOWER U.S. Head Office at 240 Clary Ave., San Gabriel, CA 91776 or the most current address provided on www.xpower.com.
    Please also have your original proof of purchase and the serial number(s) of your product(s) ready when you contact XPOWER.

XPOWER Limited Warranty (USA) (Continued)
If you are instructed to return the unit for service or replacement, please:

  1. Request an RMA (Return-Merchandise-Authorization) number.
  2. Use the original or an equivalent packaging, prepay shipping charges at your own expense to the address provided by XPOWER, with the RMA number on the shipping label or the packaging.
  3. Include all the original parts and components.
    XPOWER will inspect, assess and advise the repairs needed and applicable cost if any. For products under warranty, we will pay to ship the repaired or replaced product(s) to you if you use an address within the Contiguous United States. Otherwise, we will ship the product(s) to you at your own expense.

XPOWER Manufacture, INC.
240 Clary Avenue
San Gabriel, CA 91776 USA
www.xpower.com | 1-(855)-855-8868 | info@xpower.com
Read and save these instructions before use
Index: NA-1-A25
Edition: 2.0.Final

Documents / Resources

| xpower X-39AR Air Mover Axial Fan [pdf] Owner's Manual
X-39AR Air Mover Axial Fan, Air Mover Axial Fan, Axial Fan, X-47ATR
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals