Xpower X-34AR Professional Axial Air Mover
Introduction
Thank you for purchasing the XPOWER X-34 / X-47 Series professional axial air mover! XPOWER Manufacture, Inc. has over 25 years of manufacturing experience, bringing a series of products with the most advanced technology in today’s market. Our goal with the X-34 / X-47 Series was to bring an axial air mover never seen before. Through our research and design, we have brought a revolutionary series of air movers to the industry that provide long-life operation, excellent performance, compact design and extremely low noise. Our axial air movers are completely speed controllable– a first in the industry. We also offer a high quality dual outlet for daisy-chaining and a 3 hour timer for ease of use in professional applications. Enjoy!
Features
SEALED INDUCTION MOTOR
The advanced design SEALED INDUCTION MOTOR protects the internal motor
parts from dust and moisture accumulation, thus, making it very suitable to be
used in highly contaminated and wet environment areas.
VARIABLE SPEED CONTROL SWITCH:
An industry first, our completely variable speed control allows you to adjust
the fan speed exactly to your liking. This is extremely useful in ventilation
applications where precise volume guidelines need to be met.
DAISY CHAIN FEATURE: (For X-34AR / X-34ASR2 / X-47ATR)
2 Built-In Outlets for Additional Machines.
3-HOUR TIMER: (For X-34TR / X-47ATR)
Extremely convenient in busy contractor projects for the professional or a
busy afternoon for the handyman, 3 hour timer allows you to setup multiple
fans without having to come back to turn them off
SPECIALLY DESIGNED AIR FIN GUIDE:
Contoured to provide maximum focused and extended airflow volume and velocity.
(Technology targets air flow up to 60 ft.)
360° ROTATION- RACK STAND INCLUDED:
Full rotation of the axial air mover to fit the need of any project including
drying flooded floors, painted walls, and damp damaged ceilings.
SUPER LIGHTWEIGHT:
Durable ABS Housing
COMPACT DESIGN W/ STACKABILITY:
Stackable Up To 5 Units
Operation
- With the unit unplugged, carefully place the XPOWER unit on a stable, flat, and dry surface.
- Plug the cord into a grounded G.F.C.I. outlet only, the use of a 3-prong to 2-prong adapter is strictly prohibited.
- Turn on the switch to make sure the axial air mover is operating correctly.
- To reduce the risk of injury, close supervision is necessary when an appliance is used near children. Do not allow children to play with or around an Axial Air Mover at any time.
Daisy Chain (X-34AR / X-34ASR2 / X-47ATR)
If utilizing the Daisy-Chain feature, only use devices under 2 AMPS for 12-AMP
circuit.
X-34AR & X-34ASR2 axial air movers have an on-board circuit breaker. If the
auxiliary outlet overloads, the circuit breaker will trip. If the breaker does
trip ,unplug the units and press the circuit breaker Reset button. Plug the
units back into the power source and turn on the switch.
Timer (X-34TR / X-47ATR)
Models using a timer can be set up to 3 hours long. After the timer expires,
the axial air mover will turn off while the speed control will be at the last
set position. Set position to off and then again at a desired speed to
continue operation.
Stainless Steel Rack (For X-34ASR2)
This unit includes a durable and sturdy rack which allows 360° full angle
rotation. The rack’s stainless steel composition is anti-corrosive and rust
resistant—ideal for humid conditions.
Specifications
Model | X-34AR | X-34TR | X-34ASR2 | X-47ATR |
---|---|---|---|---|
Volt/Frequency | 115V / 60Hz | |||
Airflow | 1720 CFM | 3600 CFM | ||
Amps | 1.6 A | 2.4 A | ||
Power | 1/4 HP | 1/3 HP | ||
Weight | 16.1 lbs | 15.3 lbs | 17.8 lbs | 24.2 lbs |
Dimensions (LxWxH) | 18.6×9.4×19.2 inch | 18.6×11.1×21.1 inch | 21.9×9.8×22.5 |
inch
Cord| 20 ft / 14 AWG| 10 ft / 18AWG| 20 ft / 14 AWG
Housing| Injection-molded ABS
Positions| 360° Rotational Coverage
Daisy Chain| Incl.| N.A.| Incl.| Incl.
Timer| N.A.| Incl.| N.A.| Incl.
Safety Instructions
- To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit with wet hands or while standing in water.
- To avoid risk of injury, do not direct air flow at face or body.
- Suitable for use with solid-state speed controls.
- Use only with GFCI protected receptacles. Please contact a qualified electrician for verification and / or installation of a GFCI receptacle if necessary.
- Do not operate any unit with a damaged cord or plug. Discard axial air mover or return to an authorized service facility for examination and/or repair.
- To reduce the risk of injury, disconnect from power supply before servicing.
- o not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- Do not allow children to play with or around an axial air mover at any time.
- Do not move or carry the axial air mover while unit is operating.
- Keep air intakes and exhausts clean at all times to avoid clogging or blocking in order to prevent overheating the unit. Blocking the air intake could result in a fire or electrical hazards.
- To prevent injury to persons and to avoid objects from coming in contact with the fan blade, do not remove any screens or safety guards from this unit. Altering this unit will void your warranty.
- Always place the axial air mover on a smooth and level surface for safe operation.
- Do not use unit if defective or damaged.
- Unplug the unit before performing any maintenance, cleaning, or servicing.
- Any misuse or abuse of this product will void the warranty.
- An electronic instruction manual can be obtained through the manufacture’s website www.xpower.ws.
XPOWER Limited Warranty (USA)
XPOWER’s Limited Warranty covers the unit (excluding POWER CORD) from defects in material and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. Non-contiguous states must pay for roundtrip freight. A purchase receipt must be provided.
Important!
This warranty does not cover or apply to defects due directly or indirectly to
misuse, abuse, disassembly, alteration, corrosive chemicals, improper voltage,
fire, flood, negligence, accident, improperly or incorrectly performed
maintenance or repair, or failure to perform necessary mainte-nance or repair,
or if the use of this product is not in compliance with the instructions and
specifi-cations for its use.
Service
For Warranty service and parts replacement (US users only), you must:
- Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorization) number.
- Have original proof of purchase.
- Use the original undamaged packaging or an industrial certified packaging method.
End user will be responsible to ship the unit (with RMA Number showing on the shipping label) to the XPOWER Service Department. XPOWER will inspect, assess and advise the repairs needed and the applicable cost, if any. For users outside the US, please contact an XPOWER Distributor in your country or region for Warranty service and parts replacement.
Maintenance Instructions
- Always disconnect the axial air mover from its power source before performing any maintenance or cleaning.
- Never clean the unit with water directly.
- When not in use, unplug and store the axial air mover in a dry indoor place out of reach of children.
- To keep the axial air mover clean, use a damp cloth to wipe the surface of the housing.
Troubleshooting
SYMPTOM | PROBABLE CAUSE | ACTION |
---|
Motor Not Running
| ****
Switched Off
| Make sure unit is plugged in and switch is turned to ON mode
Power failure| Check outlet/Change to another outlet
Wiring failure| Contact XPOWER for repair
Scraping Noise From Fan
| Obstructions at the intake or exhaust of fan| Remove obstruction(s)
Fan broken| Contact XPOWER for repair
Weak Air Flow| Obstructed vents/inlets| Clean out vents/inlets
Parts List
Item # | Parts Name | Item # | Parts Name | Item # | Parts Name |
---|---|---|---|---|---|
1 | Front Air Cover | 2 | Motor | 3 | Housing |
4-1 | Circuit Breaker (X-34AR, X-47ATR) | 5-1 | AC Receptacle (X-34AR, X-47ATR) | ||
6-1 | Receptacle Plate (X-34AR, X-47ATR) | ||||
4-2 | Timer (X-34TR, X-47ATR) | 5-2 | Timer Knob (X-34TR, X-47ATR) | 6-2 | Timer |
Control Plate (X-34TR, X-47ATR)
7| Handle| 8| Capacitor| 9| Speed Knob
10| Speed Control Plate| 11| PCB| 12| Fan
13| Rear End Cover| 14| Cover| 15| Rear Air Cover
16| Rack| 17-1 / 17-2| Washer / Rack Handle| 18| Power Cord
Warranty Registration (for US user only)
For your product warranty, please complete and mail / fax this form to XPOWER
MANUFACTURE, INC. Address: 240 Clary Ave., San Gabriel, CA 91776. Tel:
626-285-3301 Fax:
626-285-3302
(For your convenience, register your product online at
xpower.com))
TO:
XPOWER Manufacture, Inc.
240 Clary Avenue
San Gabriel, CA 91776, USA
Tel: 626-285-3301, Fax:
626-285-3302