XPOWER AP-1500 Series Air Scrubber Owner’s Manual
- May 15, 2024
- XPOWER
Table of Contents
- XPOWER AP-1500 Series Air Scrubber
- Product Usage Instructions
- Safety Instructions
- Parts Description
- Items Included
- Air Scrubber Introduction
- Installation and Operation Guide
- Control Panel
- User Maintenance Instructions
- Troubleshooting Guide
- Technical Specification
- XPOWER Limited Warranty (USA)
- Documents / Resources
XPOWER AP-1500 Series Air Scrubber
Product Specifications:
- Model: AP-1500 Series, AP-1800 Series, AP-2500 Series
- Power: 115V~, 60Hz
- Manufacturer: XPOWER
- Contact: 1-(855)-855-8868
- info@xpower.com
Product Usage Instructions
-
Safety Instructions:
Before using the product, read and save the instructions provided. Failure to follow these instructions may result in hazards such as injury, fire, or electrical shock. Use caution to avoid damaging the product and voiding the warranty. -
Parts Description:
Refer to the user manual for a detailed description of each part of the air scrubber, including the machine, filters, and control panel components. -
Filters:
Make sure to install the correct filters in their respective stages according to the model number. Refer to the user manual for filter installation instructions. -
Items Included:
Check that all items listed in the instructions are included before using the air scrubber. -
Air Scrubber Introduction:
Familiarize yourself with the air scrubber’s features and functions before operation.
Installation and Operation Guide:
- Remove Filter Package (If Any): Unpack the filters before using the air scrubber.
- Installing the Handle : Follow the provided steps to correctly install the handle on the air scrubber.
- Extension Setup (Optional): If needed, set up exhaust ducting for the air scrubber.
- Selecting a Location : Choose a suitable location for the air scrubber ensuring proper ventilation and safety measures.
Special Safety Instructions for AP-1500U/AP-1800U:
Use XPOWER HEPA filter for these models to ensure safe operation of the UV
lamp. Using other filters may lead to hazardous UV light leakage.
Control Panel :
Familiarize yourself with the control panel functions and indicators for
monitoring air quality.
FAQ:
-
Q: Can I use filters from other brands with this air scrubber?
A: It is recommended to use filters specified by XPOWER for optimal performance and safety. Using other filters may affect the functionality of the air scrubber. -
Q: How often should I replace the filters?
A: Refer to the user manual for specific guidelines on filter replacement intervals based on usage and environmental conditions.
Air Scrubber Owner’s Manual
Model:
AP-1500 Series, AP-1800 Series, AP-2500 Series
- (115V~, 60Hz)
- Read and save these instructions
- www.xpower.com
- 1-(855)-855-8868
- info@xpower.com
- Index: NA-1-A40
- Edition: 2.0.Alpha
Safety Instructions
WARNING – READ AND SAVE THIS INSTRUCTIONS BEFORE USING THIS PRODUCT.
The user of electrical products may create hazards that include, but are not
limited to injury, fire, electrical shock. Failure to follow these
instructions may damage and/or impair its operation and void the warranty.
- Before operating, remove all packaging material and check for any damage that may have occurred during shipping or any missing items.
- Check power supply to ensure it matches the appliance’s specification.
- DO NOT operate any fan with a damaged cord or plug. Discard fan or return it to an authorized service facility for examination and/or repair.
- Use only on GFCI protected receptacles. Please contact a qualified electrician for verification and / or installation of a GFCI receptacle if necessary.
- DO NOT run cord under carpeting. DO NOT cover cord with throw rugs, runners, or similar coverings. DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- To reduce the risk of fire or electric shock, DO NOT use this machine with any solid-state speed control device.
- DO NOT touch this appliance or the plug with wet hands or while standing in water.
- DO NOT operate the appliance in any pooled water.
- DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are used or stored.
- DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the appliance and void the warranty.
- DO NOT cover the air inlet or outlet on the appliance.
- DO NOT direct the air flow at human faces or bodies.
- DO NOT allow children to play with this appliance.
- AUTOMATICALLY OPERATED DEVICE – To reduce the risk of injury, disconnect from power supply before servicing.
- Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, DO NOT pull the cord directly.
- DO NOT attempt to repair or adjust any electrical or mechanical functions of this appliance, as this may cause danger and void the warranty.
- If the appliance is damaged or it malfunctions, DO NOT continue to use it. Unplug the product from the electrical outlet. Refer to troubleshooting guide or contact XPOWER.
- Store in a dry area, away from exposure to sunlight, extreme temperature and humidity, or other extreme environments, when not in use.
- An electronic instruction manual can be obtained through website: www.xpower.com .
Parts Description
- Inlet Grille Cover Screw
- Inlet Grille Cover
- Handle Screw
- Rubber Pad
- Motor Inlet Grille Cover
- Time Meter*
- Motor Housing Fixator Assembly
- Motor Fixator
- Motor Right Housing
- Heat Insulation Plate
- Motor
- Bushing
- Fan
- Motor Left Housing
- Motor Control Circuit Board Assembly
- Rivet Nut
- Filter Fixator
- Flange Nut
- Handle Cover
- Handle Tube
- Housing
- Air Quality Sensor Cover
- Air Quality Sensor
- Power Switch
- Speed Switch Knob
- Control Panel
- Speed Switch Circuit Board
- Circuit Breaker
- Air Quality Sensor Box
- Pressure Gauge
- Power Cord Container Cover
- Power Cord
- Wheel Assembly
- Wheel Chassis
- Handle Screw Sleeve
- UV Light Assembly*
-
- For model AP-1500DM, AP-1800DM, AP-2500DM only.
- ** For model AP-1500U, AP-1800U only.
-
Filters
MODEL NUMBER| AP-1500D / AP-1500DM| AP-1500U| AP-1800D / AP-1800DM| AP-1800U|
AP-2500 Series
---|---|---|---|---|---
First Stage Filter| NFS16| RP20| RP24
Second Stage Filter| PF16| PF19| PF23
Third Stage Filter| CF35| CF35-490| CF50-595 (Optional)
Fourth Stage Filter| HEPA300- 406PV| HEPA300- 406PV-U| HEPA300- 490PV|
HEPA300- 490PV-U| HEPA300- PV
Items Included
Air Scrubber Introduction
- XPOWER’s unique and highly innovative Air Scrubbers create a fresh and clean environment for various purposes.
- With a special designed powerful motor, XPOWER Air Scrubbers are able to provide suction in even difficult areas.
- The included filtration system can capture a wide range of compounds and prevents organism migration from location to location.
Installation and Operation Guide
- Remove Filter Package (If Any)
- Remove the packages of the filter before the first usage.
Zero Setting
- The accuracy of the pressure gauge might be affected by transportation.
- Before the first usage, you should zero the pressure gauge in order to ensure the accuracy of the measurement.
Use a straight screwdriver to adjust the zero setting screw on the pressure gauge, until the pointer stays in the middle of the zero sector.
Installing the Handle
- Screw off the hex screw with a hex screw driver on the inlet grill cover。
- Take out the inlet grill cover.
- Put the screws through the holes on handle and the back of the machine housing.
- Fasten the screws with the nuts from the inner surface of the machine.
Extension Setup (Optional)
Exhaust Ducting
- Turn off the machine.
- Attach the ducting hose to the exhaust.
Selecting a Location (Important)
- Enclosed Area: For optimal efficiency and longer filter lifespan, the Air Scrubber should be operated in an enclosed area. Keep all doors, windows and other outside entrances to the room closed.
- Air Circulation: It’s suggested to have a constant efficient air circulation inside your working area.
- Environment Humidity: For optimal efficiency and higher filter lifespan, the Air Scrubber should not be operated in an environment with a high relative humidity level. High humidity level could cause blockage and damage to filters.
- Power Cord: The power cord has a length of 25 feet (7.6 meters). Select a location where the power cord can reach the power source.
- Inlet and Outlet Orientation: Also pay attention to the orientation of the air inlet and air outlet. Make sure the airflow won’t influence any object nearby the Air Scrubber.
- IMPORTANT: The effectiveness of the Air Scrubber can be influenced by different factors. You may also find that installing multiple Air Scrubbers may be required for larger enclosed areas.
Special Safety Instructions for AP-1500U/AP-1800U only
Please use XPOWER HEPA filter to ensure UV lamp functions safely. Other
kind of filters may cause a hazardous leakage of ultraviolet light.
Control Panel
Air Quality Monitor
- When this monitor blinks, it indicates the Air Quality Sensor is now preparing for detection.
- The digital display will show the concentration of fine particulate matter (PM2.5) in the environment in μg/m3.
- The index light will indicate the air quality category of the environment. According to the Air Quality Index developed by the United States Environmental Protection Agency (EPA), the index light corresponds to different levels of health concern as below:
Index Light | Levels of Health Concern according to the AQI by EPA |
---|---|
Green / Good | Good |
Orange (Yellow) / Moderate | Moderate or, Unhealthy for Sensitive Groups |
Red / Poor | Unhealthy, or Very Unhealthy, or Hazardous |
Time Meter (For Model AP-1500DM, AP-1800DM and AP-2500DM Only)
-
The time meter contains 3 meters. Press the setting button to switch the meters.
-
The master meter shows the total running time from the first usage to the current moment. The value of the master meter can’t be reset.
-
The value of meter 1 and meter 2 can be reset. Press the setting button up to 5 seconds to reset the value.
-
When the fan turns on, the activity indicator will blink. The running time starts to count. When the fan is off, the activity indicator will stay illuminated.
-
When the value exceeds 9999.9 hours, it will start over from 0 again.
-
Circuit Breaker
If the machine stops working, pressing the RESET BUTTON to reset the machine. -
Power Switch
Turn to “O” position to switch the power OFF. Turn to “I” position to switch the power ON.
Speed Switch
- Turn to “OFF” position to switch the fan OFF. Turn clock-wisely to any position between “MAX” and “MIN” to switch the fan ON.
- You can adjust to any desired speed variably. “MAX” is the highest speed and “MIN” is the lowest speed.
Pressure Gauge
This measures the negative pressure between the motor inlet and filter outlet.
- Before the first usage, you should zero the pressure gauge in order to ensure the accuracy of the measurement. (See Page 6: Zero Setting)
- Load all the filters, switch the power on and turn to the highest speed. If the negative pressure exceeds the values below, it indicates that the filters might have exceeded the maximum capacity of particles, and the filtration efficiency as well as the airflow have diminished. You should check, clean or replace the filters. (See Page 12: Filter Maintenance)
- Even if the pressure gauge shows negative pressure is still lower than the values below, it’s suggested to check and replace the filters every 6 months. (See Page 12: Filter Maintenance)
| AP-1500 Series| AP-1800 Series| AP-2500 Series
---|---|---|---
Without Carbon Filter| 270 Pa.| 370 Pa.| 340 Pa.
With Carbon Filter| 350 Pa.| 500 Pa.| 500 Pa.
Transportation
Transport with Trolley Handle
- Press down the trolley handle to tilt up the air scrubber on the wheels.
- Push forward to transport with the trolley handle.
User Maintenance Instructions
- Frequent maintenance is recommended on this appliance. Failure to follow the maintenance instructions may cause failure of the appliance and void the warranty.
- Before performing any maintenance or cleaning, always disconnect the Air Scrubber from its power source.
Machine Maintenance
- When not in use, unplug, and uninstall power cords and all the extensions. Store the appliance in a dry and cool indoor place. Make sure it’s out of reach of children.
- Use a damp cloth to wipe the surface of the housing. Do not clean the unit with water directly.
- Check if the grille covers are clean. Remove dirt or any other objects that could block the air inlet and air outlet.
Organize the Cord
Power cord can be stored into the power cord container at the rear of the
air scrubber.
Filter Maintenance
- To ensure the best filtration efficiency and to prevent secondary pollution of used filters, you should replace or clean the filters frequently or when the filter clean/change light illuminates. Please follow the instructions below.
- Unload the filters (See Also Page 3: Parts Description)
- Screw off the screw on the inlet grill cover and take out the inlet grill cover.
- Screw off the 4 screws on sides, and release the filter fixator.
- Then you could unload the filters from the top.
Clean the filters (See Also Page 3: Parts Description)
- *Rigid Polyester Filters:** These filters are washable with water. Use a vacuum or clean cloth to remove loose debris. And then further clean the filter with water. Use a cloth to remove the water on the filter and dry it naturally in the air.
- Pleated Media Filters: This filter is not washable. Use a vacuum to remove loose debris. If filter change light still illuminates, you might need to replace the filter.
- *HEPA Filters:** This filter is not washable or reusable. Highly concentrated particles are captured by the HEPA filter and cleaning this filter can be hazardous to human health and contaminate the nearby environment. You must replace the filter if all the other filters are clean and however the pressure gauge still shows a high negative pressure value..
Filter storage
- When not in use for a long time, you should store the filter separately from the machine.
- Always clean the filters before storage. Place the filters in a sealed plastic bag and store it in a dry and cool indoor place.
Replace the filters periodically
- Even if the pressure gauge shows negative pressure is still lower than the values below, it’s suggested to check and replace the filters every 6 months.
- Stored or unused filters are also suggested to check and replace the filters every 6 months.
WARNING: DISPOSAL OF FILTERS NO LONGER IN USE
- The particles captured by a used filter can cause adverse human health effects and contaminate the nearby environment once the filter is exposed to the open air. Adequate personal protection equipment (PPE) is required during the whole process, for example, industry approved masks, eye protectors, gloves and coveralls. You should place the used filters in a sealed plastic bag before disposing. Follow local disposal regulations.
- Reload the filters
- To ensure the best efficiency and lifespan, each filter must be reloaded in a correct position, sequence and orientation.
Tips:
- On one of the side of each filter, there is a label with an arrow showing the airflow direction.
- When placing the filter, the side with label should face up. The arrow on the label should point to the exhaust.
Troubleshooting Guide
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
Air Scrubber does not start | No electricity. | Check for power supply. |
The power cord is not properly plugged in. | Remove and reconnect the power |
cord.
The circuit breaker on the additional electrical receptacle (Daisy chain)
trips.| Remove all appliances on the additional electrical receptacle and
press circuit reset button.
Unit runs but no or very low air movement| Air outlet is blocked.| Remove
blockage.
Filters are fully loaded. The filter clean/change light illuminates.| Clean or
replace the loaded filters. (See Page 12: Filter Maintenance )
Unit runs and stops automatically and repeatedly| The input voltage is too
low. The voltage protection within the unit triggers.| Check for power supply.
Try to plug in another power outlet. Try to use an extension cord that is 16
AWG or larger and less than 25 feet.
The additional electrical receptacle has no power| The circuit breaker trips.|
Press circuit reset button.
Technical Specification
Machine Specification
MODEL NUMBER| AP-1500D / AP-1500DM| AP-1500U| AP-1800D / AP-1800DM| AP-1800U|
AP-2500D AP-2500DM
---|---|---|---|---|---
Voltage/ Frequency| 115 V~, 60 Hz
Amperage| 1.5 A| 2.0 A| 3.5 A| 4.3 A| 8.0 A
Rated Airflow| 700 CFM| 1100 CFM| 1800 CFM
Speed Control| Variable Speeds
Cord Length| 13 ft. / 4.0 m| 25 ft. / 7.6 m
- Unit Dimension
- (L) x (W) x (H)
|
- 19.4 x 21.9 x 35.8 in. /
- 49.3 x 55.5 x 91.0 cm
|
- 22.6 x 25.2 x 37.2 in. /
- 57.4 x 63.9 x 94.6 cm
| 29.4 x 26.7 x 38.8 in. / 74.8 x 67.8 x 98.6 cm
Unit Weight|
- 45.9 lbs /
- 20.8 kg
|
- 50.5 lbs. /
- 22.9 kg
|
- 65.7 lbs /
- 29.8 kg
| |
- 95.1 lbs. /
- 43.13 kg
Filter Specification
FILTER MODEL NUMBER | Type of Filter | Size | Thickness | Function |
---|---|---|---|---|
NFS16 | Nylon Mesh Filter | 16 x 16 in. | – | Primary filtration for visible and |
coarse particles.
RP20| Rigid Polyester Filter| 20 x 20 in.| 1 in.
RP24| 24 x 24 in.| 1 in.
PF16| Pleated Media Filter| 16 x 16 in.| 0.8 in.| Medium filtration for fine
dust.
PF19| 19 x 19 in.| 1.4 in.
PF23| 23 x 23 in.| 1.8 in.
CF35| Carbon Filter| 16 x 16 in.| 1.4 in.| Filtration for gases.
CF35-490| 19 x 19 in.| 14 in.
CF35-595| 23 x 23 in.| 14 in.
HEPA300- 406PV / HEPA300- 406PV-U| Plastic V-Shaped HEPA Filter| 16 x 16 in.|
11.5 in.| Final filtration for micro particles.
HEPA300- 490PV / HEPA300- 490PV-U| 19 x 19 in.| 11.5 in.
HEPA300-PV| 23 x 23 in.| 11.5 in.
XPOWER Limited Warranty (USA)
1 YEAR LIMITED WARRANTY
XPOWER-branded products purchased in the U.S. from authorized distributors
include a 1-year limited warranty. Contact XPOWER to confirm warranty
information about your product(s).
This limited warranty covers defects in materials and workmanship in your
XPOWER-branded products, purchased in the U.S. ONLY. Local warranty policy (if
any) in your country will cover products purchased outside the U.S.
IMPORTANT:
- Please finish the online warranty registration before usage. Visit www.xpower.com/service-support/warranty-registration.
- This Limited Warranty applies with its own timeliness. Contact XPOWER or visit www.xpower.com for more information.
Items mentioned but not limited to below are not covered by warranty:
- Power cord, filters or any other components considered as a “consumable parts” by XPOWER.
- Normal wear and tear.
- Problems that result, directly or indirectly, at XPOWER’s sole discretion, from:
- External causes such as accident, abuse, misuse or problems with electrical power supply.
- Disassembling, servicing or modification not authorized by XPOWER.
- Usage that is not accordant with product instructions stated in Owner’s Manual.
- Failure to follow the product instructions or lack of necessary maintenance stated in Owner’s Manual.
Before contacting XPOWER, please try one or more of the following:
- Consult this Owner’s Manual and follow the instructions of troubleshooting guide.
- Access for more advice and information that could be helpful to address your problems.
If you need additional assistance from XPOWER, please:
- Email info@xpower.com
- Call XPOWER U.S. Customer Service Department at 855-855-8868 or other numbers provided on www.xpower.com.
- Visit XPOWER U.S. Head Office at 668 S. 6th Ave., City of Industry, CA 91746 USA or the most current address provided on www.xpower.com.
Please also have your original proof of purchase and the serial number(s) of your product(s) ready when you contact XPOWER.
If you are instructed to return the unit for service or replacement, please:
- Request a RMA (Return-Merchandise-Authorization) number.
- Use the original or an equivalent packaging, prepay shipping charges at your own expense to the address provided by XPOWER, with the RMA number on the shipping label or the packaging.
- Include all the original parts and components.
XPOWER will inspect, assess and advise the repairs needed and applicable cost,
if any. For products under warranty, we will pay to ship the repaired or
replaced product(s) to you if you use an address within the Contiguous United
States. Otherwise, we will ship the product(s) to you at your own expense.
XPOWER Manufacture, INC.
Documents / Resources
|
XPOWER AP-1500 Series Air
Scrubber
[pdf] Owner's Manual
AP-1500 Series Air Scrubber, AP-1500 Series, Air Scrubber
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>