HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen User Guide

June 6, 2024
HELLA GUTMANN

mega macs 77

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective
Screen Quick Start Guide
QSMM77V6500ML0222S0
460 991-99 / 02.22

About this Quick Start Guide

Original Operating Instructions
The quick start guide comprises the most important information in a clearly visible form to facilitate the start with the mega macs 77.
1.1 Notes for the Use of the Quick Start Guide
This quick start guide contains important information relevant to operator safety.
Go to www.hella-gutmann.com/manuals to find all the manuals, instructions, references, and lists about our diagnostic devices, tools, and much more.
Please also visit our Hella Academy under www.hella-academy.com and expand your knowledge with various online tutorials and other training courses.
Please read the quick start guide entirely. Pay special attention to the first pages containing the safety instructions.
They are provided solely to assure your safety when working with the device.
You are recommended to read the individual work steps in the manual again while working with the device, in order to avoid danger to personnel and equipment or operating errors.
The device shall be operated exclusively by personnel qualified in vehicle engineering. Information and knowledge included in this training are not explained further in this quick start guide.
The manufacturer reserves the right to modify this quick start guide and the device itself without prior notice. We, therefore, recommend checking for any updates. This quick start guide must accompany the device in case of sale or other transfer.
The quick start guide must be kept for the entire service life of the device and accessible at any time.
1.2 Scope of Functions
The range of functions of the software may vary depending on the country, the licenses acquired, and/or the optionally available hardware. This documentation may therefore describe functions that are not available on the individual device. Missing functions can be enabled by acquiring a corresponding license subject to charge and/or additional
supporting hardware.

Safety Precautions

2.1 Safety Precautions – Risk of Injury

| When working on the vehicle, there is a risk of injury through rotating parts or rolling of the vehicle. Therefore regard the following:

  • Protect the vehicle against rolling away.
  • Additionally, place gear selector lever of AT vehicles to park position.
  • Deactivate the start/stop system to avoid an inadvertent engine startup.
  • Connect the device to the vehicle only when the ignition is switched off.
  • Do not reach into rotating components when the engine is running.
  • Do not run cables near rotating parts.
  • Check the high-voltage parts for damage.

---|---

2.2 Safety Precautions for the mega macs 77

|

To prevent incorrect handling and resulting injuries to the user or destruction of the device, pay attention to the following:

  • Ensure that the power plug is accessible.
  • Select functions and menus on the touch screen display only with clean fingers. Do not use tools such as a screwdriver.
  • Only connect the original power adapter to the power cord (supply voltage 10–15 V).
  • Always use the original battery.
  • Protect the TFT LCD and the device from long periods of exposure to solar radiation.
  • Protect the device and the connecting cable from hot components.
  • Protect the device and the connecting cables from rotating parts.
  • Regularly check the connecting cables/accessory parts for damage (destruction of the device due to a short circuit).
  • Connect the device exclusively according to the user manual.
  • Protect the device from fluids such as water, oil, or gasoline. The mega macs 77 is not waterproof.
  • Protect the device from strong impacts and do not drop it.
  • Do not open the device on your own. Only technicians authorized by Hella Gutmann are allowed to open the device. Warranty and guarantee will be rendered void in any case of unauthorized tampering of the device or if the protective seal is damaged.
  • Immediately contact Hella Gutmann or a Hella Gutmann trading partner in case of any malfunctions.

---|---

2.3 Safety Precautions for Testing/Measuring Devices

|

  • Perform measurements only on electric circuits that are not directly connected to the line voltage.
  • Never exceed the maximum permissible voltage load of 200 V peak alternating voltage (AC) or 200 V direct current voltage (DC) respectively.
  • Do not exceed the voltage limits indicated on the connecting cables.
  • The voltage values to be measured must be shielded twice or extra from dangerous line voltage. The voltage limits printed on the test leads must not be exceeded. Pay attention that the allowed measuring range of 200 V/DC / 200 V peak is not exceeded when measuring the positive and negative voltage at the same time.
  • Never perform measurements on ignition systems (secondary side).
  • Regularly check the test and measuring devices for damage.
  • Always connect the test and measuring devices to the measurement module (MT 77) first.
  • Do not touch the connections/measurement points during the measurement.

---|---

Product Description

3.1 Delivery contents

Pieces

| Designation|

---|---|---
1| mega macs 77| HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti
Reflective Screen - parts1
1| Docking station| HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti
Reflective Screen - parts2
1| DT VCI| HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective
Screen - parts3
1| USB cable for connection to the DT VCI|
1| USB cable for connection to a PC|
1| Mains supply and power cable
for the mega macs 77|
1| HGS data carrier|
1| Quick Start Guide|

3.1.1 Checking Delivery Contents
Please check the delivery contents upon receiving your device so that complaints can be issued immediately regarding any potential damage.
Proceed as follows to check the delivery contents:

  1. Open the package supplied and check for completeness based on the delivery slip.
    Should you identify any damage to the package, then open the package in the presence of the delivery service and check the device for hidden damage. Any transport damage to the package supplied and damage to the device shall be registered in a damage report by the delivery service.

  2. Take the device out of the packaging.


|

CAUTION

---|---
The danger of short circuits due to loose parts in or on the device.
The danger of destruction of the device/the automotive electronics
Never put the device into operation if you suspect that there are loose parts in or on it. Please contact the Hella Gutmann repair service or a Hella Gutmann trading partner immediately in this case.
3. Check the device for mechanical damage and shake it slightly to ensure that there are no loose parts inside.

3.2 Intended Use
The mega macs 77 is a mobile device for detecting and rectifying faults in automotive electronic systems.
The device enables access to extensive technical data such as wiring diagrams and service data, set values, and descriptions of vehicle systems. A lot of this data is transferred to the device directly from the Hella Gutmann diagnostic database via an online connection. Therefore, the device must be permanently online.
The device is not suitable for repairing electrical machines and tools or home electrics. Diagnostic devices from other manufacturers will not be supported.
If the device is used in a way not authorized by Hella Gutmann, the safety of the device may be influenced.
The device is intended for industrial use. Outside of industrial environments, e.g. in commercial areas or in the center of a town, radio interference suppression measures may be necessary.
3.3 Using the Bluetooth Function
The terms of use of the Bluetooth® function may be restricted or prohibited through law or corresponding legal regulations in certain countries.
Pay attention to the provisions in force in the respective country before using the Bluetooth function®.
3.4 mega macs 77

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
overview1

|

Designation

---|---
1| TFT LCD (touch screen)
2| mega macs 77
3| Docking station

3.5 Operating the tool

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
icon10

|

NOTICE

---|---

  • Damage or destruction of the display
  • Never touch the display using a tool or pointed metal object.
  • Only use fingers.

3.6 Connections of the mega macs 77

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
overview2

|

Designation

---|---
4| USB device interface
Use the USB device interface for data exchange between the PC and the device.
5| 2x USB host interface
The USB host interfaces (USB interfaces for short) can be used to connect external tools such as a printer.
6| Power supply socket
This is the power supply of the device and the internal battery charge connection.
7| ON/OFF button
Switch the tool on or off.
8| Additional module slot
Another module can be inserted here.
9| Positioning handle
Using the positioning handle, the tool can be set up, carried, or fixed to the steering wheel in the vehicle.
10| Oscilloscope 1 connections
Connect a test lead to Scope 1.

  • blue = signal
  • black = ground

11| ST3 connection
Connect additional measuring instruments such as a clamp meter here.
12| Oscilloscope 2 connections
Connect a test lead to Scope 2.

  • red = signal
  • black = ground

13| Measurement module MT 77
This module contains a 2-channel oscilloscope for measured variables such as the following:

  • Voltage
  • Current (with current clamp)
  • Resistance
  • Pressure

3.7 Connections of the Docking Station

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
overview3

|

Designation

---|---
14| DVI-D interface
Transmit digital signals with the DVI-D interface. These signals can be depicted with the help of a screen or projector.
15| Ethernet interface
Use the Ethernet interface to connect the device e.g. to the following hardware:

  • PC
  • Printer
  • Network

16| 4x USB host interface
The USB host interfaces (USB interfaces for short) can be used to connect external tools such as a printer.
17| Power supply socket
Here you can supply the docking station with the power to charge the battery of the mega macs 77.
18| Docking interface
Connect the device with the docking station here.

3.8 DT VCI Connections

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
overview5

|

Designation

---|---
19| DT VCI for diagnostic port in the vehicle
20| Retaining strap for mounting e.g. a lanyard
21| Green and blue indicator light (LED)
The indicator lights show the operating condition of the DT VCI.
22| Micro USB interface for the USB cable to USB interface of the PC

3.8.1 Meaning of the Flashing Frequencies

Status display

|

Meaning

---|---

Blue LED

|

Green LED

LED switched off| LED switched off|

  • Software inactive/defective
  • No voltage present
  • DT VCI defective.

LED flashes quickly (lx per sec.).| LED switched off|

  • Update failed
  • Update invalid
  • DT VCI defective.

LED flashes slowly (every 3 sec.).| LED switched off|

  • Update failed
  • Update invalid
  • DT VCI defective.

LED flashes slowly (every 3 sec.).| LED permanently on with regular brief interruptions| DT VCI ready for operation.

Installation of the Hella Gutmann Drivers Package

4.1 System Requirements of Hella Gutmann Drivers

  • Windows 7 SP1 or higher
  • Windows administrator rights

4.2Installation of the Hella Gutmann Drivers Package
To obtain all the data about the related vehicle provided by Hella Gutmann, the device requires a permanent online
connection and the installed driver package Hella Gutmann Drivers. To keep the connection costs down, Hella
Gutmann recommends a DSL connection and a flat rate.

  1. Install the Hella Gutmann Drivers on the office or repair shop PC.
    The driver package Hella Gutmann Drivers program is on the supplied HGS data carrier.

  2. Connect the device to a web-compatible PC.
    Once the symbol appears in the top toolbar, the connection to the HGS server is set up successfully and active.

Putting the mega macs 77 into Operation

This section gives a description of how to switch the device on and off as well as all the necessary steps for the first use of the device.
5.1 Charging the Battery with the Power Adapter
Prior to the initial start-up of the device, charge the battery for at least 8 to 10 h while the device is switched off.
Proceed as follows to charge the battery with the power adapter:

  1. Connect the power supply plug into the device’s socket.
  2. Plug in the power plug into the socket.
    The battery will be charged.

5.2 Charging the Battery through Docking Station
Prior to the initial start-up of the device, charge the battery for at least 8 to 10 h while the device is switched off.
Proceed as follows to charge the battery through the docking station:

  1. Insert the voltage supply plug into the docking station port.
  2. Plug in the power plug into the socket.
  3. Place the mega macs 77 onto the docking station.
    The battery will be charged.

5.3Switching On the Device

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
icon11

|

NOTE

---|---

  • When starting the device for the first time and after every software update, you need to confirm the general terms and conditions (GTC) of the Hella Gutmann Solutions GmbH.
    Otherwise, certain device functions will be unavailable.

Proceed as follows to switch on the device:

  1. Briefly push the ON/OFF button.
    The general terms and conditions appear.

  2. Read the GTCs and confirm them at the end of the text.

Now you can start working with the device.
5.4 Displaying Licenses

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
icon11

|

NOTE

---|---
In order to use the full scope of the purchased licenses, you need to connect the device to the HGS server prior to the first start-up.

Proceed as follows to have indicated the start of the contract, the date of purchase, and the included and additionally available licenses:

  1. Go to > Settings > User profile > Contracts.
  2. Select > My licenses<.
    The window My licenses is indicated.

The start of the contract, the date of purchase, and the included and additionally available licenses are indicated.
5.5 Switching off the tool
Proceed as follows to switch off the device:

  1. Briefly push the ON/OFF button.
  2. Observe the confirmation prompt.
  3. Select > OK<.

The device will be switched off.

Configuring the device

Configure all interfaces and functions under a > Settings.
6.1 Configuring the Interfaces
Configure the interfaces for Wi-Fi and Ethernet (connection only through docking station) here. Configure the interfaces for Wi-Fi and Ethernet under a

Settings > Device.
Configure the interfaces for the printer under a’ > Settings > Print.
6.1.1 Configuring the Ethernet
Make your network settings here.
Proceed as follows to connect the device to a network (router) via the Ethernet interface of the docking station:

  1. Insert the Ethernet cable (not included in the delivery contents) into the Ethernet port of the docking station and the remote station.

  2. Use a **to select > Settings**

  3. Select > Device<

  4. Select > Ethernet<

  5. Open the list under IP address mode with ∨.
    If > Determine automatically (DHCP)< (recommended) is set, the DHCP server of the network will assign an IP address to the mega macs 77 automatically. This option is set ex-works.
    If > Determine manually< is selected, enter a free network IP address, e.g. 192.168.246.002 . under IP address.

  6. Select > Determine automatically (DHCP)< (recommended) or > Determine manually<.

  7. Click to > Connect<. The selection will be saved automatically.

You can use the Ethernet connection now.
6.1.2 Configuring WLAN
Make your WLAN settings here.
WLAN stands for Wireless Local Area Network. Data is transmitted wirelessly via a router and DSL modem (access point). The various devices log in to the WLAN router.
6.1.2.1 Searching for and Installing a Wi-Fi Interface
Proceed as follows to connect the device to a network (router) through Wi- Fi:

  1. Use ****to select > Settings.

  2. Select > Device<.

  3. Select > Wi-Fi<.

  4. Select the check box Activate Wi-Fi to view available wireless networks. The available wireless networks are displayed.

  5. Select the requested wireless network.

  6. Open the list under IP address mode with “.
    If > Determine automatically (DHCP)< (recommended) is set, the DHCP server of the network will assign an IP address to the mega macs 77 automatically. This option is set ex-works.
    If > Determine manually< is selected, enter a free network IP address, e.g. 192.168.246.002 . under IP address.

  7. Select > Determine automatically (DHCP)< (recommended) or > Determine manually.< The selection will be saved automatically.

  8. Enter the Wi-Fi password.

  9. Click to > Connect<.
    The input is saved automatically.
    The name of the selected wireless network is displayed under Connected wireless network
    Use ![HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen

  • icon12](https://manuals.plus/wp-content/uploads/2022/03/HELLA-GUTMANN- QSMM77V6500ML0222S0-Mega-Macs-77-Anti-Reflective-Screen-icon12.png)to call up detailed information about the connected wireless network.

    1. Once the WLAN symbol ****appears in the top toolbar, the online connection is set up between the device and the Internet. You can use the WLAN connection now.

6.1.2.2 Resetting the Wi-Fi Configuration
You can reset the Wi-Fi configuration if you wish to remove the automatic connection between the device and the already created wireless network.
Proceed as follows to delete all known wireless networks:

  1. Use = to select > Settings.
  2. Select > Device<
  3. Select > Wi-Fi<.
  4. Select HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen - icon12
  5. Click to > Reset Wi-A configurations.

The Wi-A configuration is reset.

Working with the Device

7.1 Diagnostics
The manufacturer-specific vehicle communication enables the data exchange to the vehicle systems that shall be checked. The prevailing in-depth diagnostics and variety of diagnostics depend on the functional scope of the ECU.
The following parameters are available under Diagnostics:

  • > Trouble codes<
    Here you can read out and delete trouble codes stored in the trouble code memory of the ECU. Information on the fault code is available too.

  • > OBD diagnostics<
    Start the OBD2 diagnostics through emission-relevant components here. Here you select merely the vehicle manufacturer and the fuel type.

  • > Parameters<
    Here the device indicates the real-time data or conditions of the components from the ECU graphically and alphanumerically.

  • > Actuators<
    Here you can activate or deactivate actuators with the help of the ECU.

  • > Basic settings<
    Here you can reset components to their basic setting.

  • > Codings<
    Here you can code components in the ECU.

  • > Test function<
    Here you can perform special tests/self-tests.

  • > Service resets<
    Here you can reset the service interval. The service reset can be done manually or with the diagnostic device.

7.1.1 Preparing Vehicle Diagnostics
The selection of the correct vehicle and sufficient vehicle electrical system voltage (>12 V) are two basic preconditions for trouble-free vehicle diagnostics. The device provides assistance to simplify the selection, e.g. indicating the installation position of the diagnostic port, vehicle identification through VIN, or indication of the battery voltage.
Proceed as follows to prepare vehicle diagnostics:

  1. Select a requested vehicle in the App launcher through >Vehicle selection<.
    There are various options to select a vehicle. The following options are available:
    • Vehicle database
    The vehicle can be searched using the following parameters:
    – Manufacturer
    – Fuel type
    – Model
    • Vehicle search
    The vehicle can be searched using the following parameters:
    – VIN
    – HGS number
    – Manufacturer key no./Type key no.
    • Car History
    Select vehicles that are already saved and diagnostic results here.

|

CAUTION

---|---
Rolling of vehicle
Risk of injury or material damages
Proceed as follows before startup:

1. Apply the parking brake.
2. No gear is engaged.
3. Regard the window with information and instructions.  

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
icon10

|

NOTICE

---|---
The danger of short circuit and voltage peaks when connecting the DT VCI
The danger of destruction of automotive electronics
Switch off the ignition before connecting the DT VCI to the vehicle.
2. Insert the DT VCI into the vehicle’s diagnostic connector.
Both LEDs of the DT VCI flash. The DT VCI is ready for operation.

  1. Select > OBD diagnostics< in the App launcher.

Now select the type of diagnostics.
7.2 Information
The following pieces of information are indicated here:

  • Diagnostic database
  • Service data
  • Component location
  • Technical data

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
icon11

|

NOTE

---|---
You require an online connection if you wish to access all available information.

Proceed as follows to call up vehicle information:

  1. Select the requested piece of information under Information in the App launcher.
  2. Observe the info window where necessary.
    Certain pieces of information may not be available depending on the selected vehicle.

Measurements

HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
icon11

|

NOTE

---|---
The use of the measurements menu requires the optionally available measurement module (MT 77).

Here you can select measured variables and channels. Then you can perform various measurements.
Measurement technology involves digital signal acquisition and output. A voltage signal is scanned and stored at intervals of a few microseconds. Once there are enough values stored, the scans are displayed as a signal curve onscreen.
Just perform measurements under > Oscilloscope<.
8.1 Performing Oscilloscope Measurements
Proceed as follows to perform oscilloscope measurements:

  1. Insert the test lead into the MT 77 and connect it to the relevant component.

  2. Select > Oscilloscope< in the app launcher.
    The Oscilloscope window is displayed.

  3. Activate the check box for the desired measured variable and the oscilloscope channel.

  4. Select > Start measurement<.
    Measurement will be started.

HELLA GUTMANN SOLUTIONS GMBH
Am Krebsbach 2
79241 Ihringen
GERMANY
Phone: +49 7668 9900–0
Fax: +49 7668 9900–3999
info@hella-gutmann.com
www.hella-gutmann.com
© 2022 HELLA GUTMANN SOLUTIONS GMBH
1 STUECK/PIECE(S)
HELLA GUTMANN QSMM77V6500ML0222S0 Mega Macs 77 Anti Reflective Screen -
barcodeMade in Germany

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals