UBIQUITI LTU-Pro 5GHz PtMP LTU CPE Radio with Integrated 24dBi Antenna User Guide
- June 6, 2024
- UBIQUITI
Table of Contents
- UBIQUITI LTU-Pro 5GHz PtMP LTU CPE Radio with Integrated 24dBi Antenna
- Package Contents
- Installation Requirements
- Hardware Overview
- Pole Mounting
- Connecting Power
- Installer Compliance Responsibility
- Specifications
- Safety Notices
- Electrical Safety Information
- Compliance
- IMPORTANT NOTE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UBIQUITI LTU-Pro 5GHz PtMP LTU CPE Radio with Integrated 24dBi Antenna
Package Contents
Installation Requirements
- LTU PtMP AP, such as model LTU-Rocket
- 13 mm wrench
- Surge protection should be used for all outdoor installations. We recommend that you
use two Ethernet Surge Protectors, model ETH-SP-G2, one near the device and the other
Note: For guidelines about grounding and lightning protection, follow your local electrical regulatory codes.
Outdoor, shielded Category 6 (or above) cabling and shielded RJ45 connectors are required for all wired Ethernet connections.
Hardware Overview
This 10/100/1000 Ethernet port is used to connect the power and should be connected I This 10/100/1000 Ethernet port is used to connect the power and should be connected
Pole Mounting
Connecting Power
WARNING: The switch port must comply with the power specifications listed in the “Specifications”.
Accessing the Configuration Interface
- Make sure that your host system is connected via Ethernet to the device.
- Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.
- Launch your web browser and type https://192.168.1.20 in the address field. Press enter (PC) or return (Mac).
- Select your Country and Language. You must agree to the Terms of Use, EULA, and Privacy Policy to use the product. Click Continue.
The LTU Configuration Interface will appear, allowing you to customize your settings as needed. To have your AP configure your device, proceed to “Find My AP”.
UNMS Management
You can manage your device using UNMS, which lets you configure, monitor,
upgrade, and back up your devices using a single application. Get started at
www.unms.com
-
Click the WIFI icon.
-
In the Wireless Settings section, change the channel bandwidth (default: 20 MHz) as needed.
Note: If the AP’s channel bandwidth is set to 50 MHz and your device is set to 20 MHz, then your device will not see that AP and you should change the channel bandwidth on your device. -
Click Find AP.
-
The device will scan for nearby APs. Click Select for the appropriate AP. To run the search again, click Scan.
-
Follow the on-screen instructions.
Installer Compliance Responsibility
The Auto Output Power field is provided to the professional installer to assist in meeting regulatory requirements.
Specifications
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
Electrical Safety Information
- Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
- Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
- The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
- Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
- Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
- Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an
individual basis, and, where applicable, specify arbitration instead of jury
trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operations of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This radio transmitter has been approved by FCC.
This radio transmitter has been approved by ISED Canada.
The device for operation in the band 5150-5250 MHz is only for indoor use to
reduce the potential for harmful interference to co-channel mobile satellite
systems.
IMPORTANT NOTE
Radiation Exposure Statement
- This equipment complies with radiation exposure limits set forth for an uncontrolled environment.
- This equipment should be installed and operated with minimum distance 141 cm between the radiator and your body.
- This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Australia and New Zealand
A Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment, this equipment may cause radio interference.
CE Marking
CE marking on this product represents the product is in compliance with all
directives that are applicable to it.
Country List
Note: This device meets Max. TX power limit per ETSI regulations.
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the
5150 – 5350 MHz frequency range within all member states.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA
member states. Other countries listed may use the 5.8 GHz, frequency band.