USP-RPS Quick Start Guide
Package Contents
System Requirement
- Linux, Mac OS X, or Microsoft Windows 7/8/10
- Java Runtime Environment 1.6 (1.8 or newer recommended)
- Web Browser: Google Chrome (Other browsers may have limited functionality.)
- UniFi Controller software v5.12.x (or newer), available at: ui.com/download/unifi
1. Touchscreen Display
Bootup Animation| Initializing.
Steady White| Factory defaults, waiting for adoption.
Steady Blue| Successfully adopted by a network and working properly.
Location Animation| This indicates that you clicked Locate in the UniFi
Controller software. The software will also display the location of the device
on the map.
2. RJ45 Speed/Link/Activity LED
Off| No Link
Green| Link Established at 10/100/1000 Mbps Flashing Indicates Activity
3. LAN Port
The RJ45 port supports a 10/100/1000 Ethernet connection. Set to DHCP Client
by
4. Reset Button
Resets to factory defaults. The device should be running after bootup is
complete. Press and hold the Reset button for about 10 seconds until the
display indicates that the device has reset itself. After a few seconds, the
LED will turn off, and the device will automatically reboot.
5. USP RPS LED (Ports 1 – 6)
The LED lights up blue when there is an active power connection.
6. USP Connect DC Output (Ports 1 – 6)
Connect the included USP Cable to a UniFi device with a USP Connect DC input.
(Additional USP cables are sold separately as model USP-Cable.)
7. Power Port
Connect the included Power Cord to the Power port.
Installation Requirements
Phillips screwdriver
Standard-sized, 19″ wide rack with a minimum of 1U height available
For indoor applications, use Category 5 (or above) UTP cabling approved for
indoor use.
For outdoor applications, shielded Category 5 (or above) cabling should be
used for all wired Ethernet connections and should be grounded through the AC
ground of the
power supply.
We recommend that you protect your networks from harmful outdoor environments
and destructive ESD events with industrial-grade, shielded Ethernet cable from
Ubiquiti.
For more details, visit: ui.com/toughcable
Note : Although the cabling can be located outdoors, the USP-RPS itself should be housed inside a protective enclosure.
Hardware Installation
Connecting Power
Connecting the USP Cable
Some UniFi devices have a proprietary USP port that allows them to be connected using a Ubiquiti USP-Cable (sold separately).
Note : The stop line should not be visible when the cable is completely plugged in.
Note: The stop line should not be visible when the cable is completely plugged in.
Connecting to the LAN
Download and install the latest version of the UniFi Controller software at
ui.com/download/unifi and follow the on-screen instructions.
Note: If you already have UniFi Controller v5.12.x or newer installed,
skip to “Adopting the USP-RPS”.
After you have installed the software and run the UniFi Installation Wizard, a
login screen will appear for the UniFi Controller management interface. Enter
the admin name and password that you created and click Sign In.
To adopt the UniFi Switch, proceed to “Adopting the USP-RPS”.
You can manage your network and view network statistics using the UniFi
Network Controller management interface. For information on using the UniFi
Network Controller
software, refer to the User Guide located on our website at:
ui.com/download/unifi
Adopting the USP-RPS
-
From the UniFi Controller dashboard, click Devices in the left menu bar.
-
On the Devices screen, locate the USP-RPS in the list of devices under the Model column. To adopt the USP-RPS, click Adopt.
-
The System LED on the device will turn blue to confirm that it has been successfully adopted.
Specifications
USP-RPS
Dimensions| 442.40 x 325.60 x 43.70 mm
(17.42 x 12.82 x 1.72″)
---|---
Weight With Mount Brackets| 5.500 kg (12.13 lb)
5.590 kg (12.32 lb)
Interfaces Networking Management Power Output| (1) 10/100/1000 Mbps RJ45 Port
Ethernet In-Band (6) RPS DC Ports
Max. Power Consumption| 995W
Power Method| (1) Universal AC Input, 100 to 240VAC
Power Supply| Internal 350W AC/DC Internal 645W AC/DC
Supported Voltage Range| 100 – 240VAC
Display| 1.3″ Color Touch Panel
LED System RJ45 USP RPS| Status Link/Activity Activity
ESD/EMP Protection| Air: ± 16 kV, Contact: ± 12 kV
Shock and Vibration| ETSI300-019-1.4 Standard
Operating Temperature| -5 to 45° C (23 to 113° F)
Operating Humidity| 10 to 90% Noncondensing
Certifications| CE, FCC, IC
RPS
Total Output Power
52VDC
11.5VDC| 11.54A (600W)
30.44A (350W)
Max. Output Power per RPS Port
52VDC
11.5VDC| Max. Output Power per RPS Port
52VDC
11.5VDC
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
WARNING : To reduce the risk of fire or electric shock, do not expose this
product to rain or moisture.
WARNING : Do not use this product in a location that can be submerged by
water.
WARNING : Avoid using this product during an electrical storm. There may
be a remote risk of electric shock from lightning.
Electrical Safety Information
-
Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than that specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
-
There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
-
This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations. -
The product is used in Service Access Area.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an
individual basis, and,
where applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand
Warning : This equipment is compliant with Class A of CISPR 32. In a
residential environment, this equipment may cause radio interference.
CE Marking
CE marking on this product represents the product is in compliance with all
directives that are applicable to it.
v© 2021 Ubiquiti Inc. All rights reserved.
WEEE Compliance Statement
Declaration of Conformity
Online Resources
Documents / Resources
|
UBIQUITI USP-RPS UniFi SmartPower
RPS
[pdf] User Guide
USP-RPS UniFi SmartPower RPS, USP-RPS, UniFi SmartPower RPS
---|---
References
- UniFi - Rethinking IT - Ubiquiti
- Ubiquiti - Warranty
- UniFi - Rethinking IT - Ubiquiti
- community.ubnt.com/
- WEEE Compliance Statement
- Ubiquiti - Rethinking IT
- Software Downloads - Ubiquiti
- UniFi - Rethinking IT - Ubiquiti
- Ubiquiti - Warranty
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>