HYTRONIK HC005S Super Compact On-Off HF Sensor Instruction Manual

June 6, 2024
HYTRONIK

HYTRONIK HC005S Super Compact On-Off HF Sensor

Technical Specifications

Product Type:| ON/OFF Control Microwave Motion Sensor

Against wireless signals interference

---|---
Operating Voltage:| 220-240VAC 50/60Hz
HF System:| 5.8GHz CW radar
Transmission Power:| < 0.2mW
Rated Load:| 800W (resistive load)

400VA (capacitive load)

Detection Angle:| 30~150°
Power Consumption:| < 0.5W
Detection Range :| Max. 10 meters in diameter, adjustable
Time Setting:| 5s ~ 30 min.
Mounting:| Indoors, Ceiling & walling mounted
Light Control:| 2~50 lux, disable
Working Temperature:| -20 ~ +70°C

Dimensions (mm)

Functions

  1. Lux Off Function
    The built-in daylight sensor can measure ambient natural light and switch off the fixture automatically whenever artificial light is not required (natural light lux level exceeds daylight threshold).

  2. Zero-cross Relay Operation
    Designed in the software, the sensor switches on/off the load right at the zero-cross point, to ensure the in-rush current is minimised, enabling the maximum life-time of the relay.

  3. Loop-in and Loop-out Terminal
    Double L N terminal makes it easy for wire loop-in and loop-out, and saves the cost of terminal block and assembly time.

Wiring Diagram

To connect several standard control gear with 1 sensor (ON/OFF function), the wiring should be.

HYTRONIK HC005S Super Compact On-Off HF Sensor-fig3

With Tridonic switchDIM ballast / driver ( Excel ballast/driver, corridor function) , this sensor can also achieve tri-level dimming control:

Settings

Detection Range
This determines the effective range of the motion detector and is set by DIP switches at the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the detection range. The following settings are available.

Hold Time
Select the dip switch configuration for the full brightness on-time after presense detection. Please note that this function is disabled when the natural daylight exceeds the daylight threshold setting more than 5 minutes.

Daylight Sensor
This setting holds off the 100% light output should there sufficient daylight and is set using DIP switches at the sensor, refer to figure. The following settings are available.

  • In disable mode the fixture(s) will always be on with motion detection regardless of the ambient lux level.

Troubleshooting

MALFUNCTION CAUSE REMEDY CAUSE REMEDY

The fixture does not light up

| Incorrect daylight threshold setting| Adjust daylight threshold setting
Faulty fixture| Replace fixture
No power supply| Check power to sensor
Detection zone not targeted| Check detection area setting
The fixture is always on| Continous movement in the detection zone| Check detection area setting
The fixture is on when it should not| Sudden change in temperature due to weather (wind, rain,

snow) or air expelled from fans, or open windows

| Adjust zone, change installation site