VIJ5301 Insulated Jacket For Outdoor Products
IMPORTANT: Before you build the frame, you must take into consideration
the total weight of the liner, grill and any finishing materials.
Refer to the cutout dimension table for the proper framing dimensions for the
insulation jacket. Determine the entry point for both the gas inlet and
electrical connections. Make the 4” square holes for gas and electrical
connections (rear or bottom access) based on your requirements.
Note: that the electrical connections are located on the left side and
the gas connections are located on the right side.
A Carpenter’s “spirit level” should be used to assure that the framing is
level, both front to back and side to side.
Note: Never under any circumstance should you install the transformer or
run a quick disconnect hose in-between the grill and the inside of the
insulating jacket.
Liner Installation
Position the liner into the frame. No part of the combustible enclosure can protrude above the top surface or in front of the face surface of the liner. Shim the liner if necessary.
Grill Installation
Use the proper equipment to support the grill. Place the grill into the liner
and engage it over the liner lip across the back and sides. The liner is
designed to support the grill without additional fasteners.
If desired any gap remaining between the liner and the combustible enclosure
may be filled with a non-combustible sealant or caulk.
Cutout Dimensions
Model | A | B | c | D | E | F |
---|---|---|---|---|---|---|
LIJ27 | 33″ | |||||
(83.8 cm) | 5″ | |||||
(12.7 cm) | 23 3/4″ | |||||
(60.3 cm) | 4 1/2″ | |||||
(11.4 cm) | 3″ | |||||
(7.6 cm) | 11 5/8″ |
(29.5 cm)
VIJ5301I LIJ30| 36″
(91.4 cm)| 5″
(12.7 cm)| 26 1/2″
(67.3 cm)| 4 1/2″
(11.4 cm)| 3″
(7.6 cm)| 11 5/8″
(29.5 cm)
VIJ5361I LIJ36| 42″
(106.7 cm)| 5″
(12.7 cm)| 23 3/4″
(60.3 cm)| 4 1/2″
(11.4 cm)| 3″
(7.6 cm)| 11 5/8″
(29.5 cm)
VIJ5421 I LIJ42| 48″
(121.9 cm)| 5″
(12.7 cm)| 26 1/2″
(67.3 cm)| 4 1/2
(11.4 cm)| 3″
(7.6 cm)| 11 5/8″
(29.5 cm)
VIJ5541 I LIJ54| 60″
(152.4 cm)| 5″
(12.7 cm)| 26 1/2″
(67.3 cm)| 4 1/2″
(11.4 cm)| 3″
(7.6 cm)| 11 5/8″
(29.5 cm)
VIJSB2 I LIJSB2| 15 1/2″
(39.4 cm)| 3 1/2″
(8.9 cm)| 26 1/2″
(67.3 cm)| 4 3/4″
(12.1 cm)| 3 1/8″
(8.0 cm)| 11 5/8″
(29.5 cm)
VIJPB I LIJPB| 26 1/4”
(68.0 cm)| 5 3/8″
(13.7 cm)| 23 7/8″
(62.7 cm)| 4 3/4″
(12.1 cm)| 3 1/8″
(8.0 cm)| 11 5/8″
(29.5 cm)
WARNING
The regulator to be installed outside the insulating jacket. It can be
positioned anywhere in the gas supply line between the grill and the shutoff
valve.
Gas tubing should never be installed within the insulated jacket.
Insulated Jacket Dimensions
LIJ27
VIJ5301 / LIJ30 VIJ5361 / LIJ36 VIJ5421 / LIJ42 VIJ5541 /
LIJ54
VIJSB2 / LIJSB2 VIJPB / LIJPB Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
662-455-1200
For product information, call 1-888-(845-4641) or visit our web site at
vikingrange.com
072267-000C
(021523)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>