MicroTouch SK-150P-A1 Slimline Kiosk Touch Monitor User Manual
- June 6, 2024
- MICROTOUCH
Table of Contents
SK-150P-A1 Slimline Kiosk Touch Monitor
User Manual
About This Document
No part of this publication may be reproduced, transmitted, transcribed,
stored in a retrieval system, or translated into any language or computer
language, in any form or by any means, including, but not limited to,
electronic, magnetic, optical, chemical, manual, or otherwise without prior
written permission of MicroTouchTm a TES Company.
The information in this document is subject to change without notice.
MicroTouchTM a TES Company makes no representations or warranties with respect
to the contents herein and specifically disclaims any implied warranties of
merchantability or fitness for a particular purpose. MicroTouchTm a TES
Company reserves the right to revise this publication and to make changes from
time to time in the content hereof without the obligation of MicroTouchTm a
TES Company to notify any person of such revisions or changes. Windows is a
registered trademark of Microsoft, Inc. Other brands or product names are
trademarks of their respective holders.
Compliance Information
For FCC (USA)
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy, and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For IC (Canada)
CAN ICES-3(B)/NMB-3(B)
For CE (EU)
The device complies with the EMC Directive 2014/30/EU and Low Voltage
Directive 2014/35/EU
Usage Notice
| Warning – To prevent the risk of fire or shock hazards, do not expose
the product to moisture.
---|---
| Warning – Please do not open or disassemble the product as this may
cause electric shock.
| Warning – The power cord shall be connected to a socket-outlet with
earthing connection.
| Warning – The cable cover cannot be removed under normal use
conditions.
| Warning – Stability Hazard. The touch monitor may fall, causing serious
personal injury or death. To prevent injury, this touch monitor must be
securely attached to the wall in accordance with the installation
instructions.
Precautions
Please follow all warnings, precautions, and maintenance as recommended in
this user’s manual to maximize the life of your unit.
Do:
- Turn off the product before cleaning.
- Use a soft cloth moistened with mild detergent to clean the product housing.
- Use only the qualified power adapter that comes with your device.
- Disconnect the power plug from the AC outlet if the product is not going to be used for an extended period of time.
Don’t:
- Do not use abrasive cleaners, waxes or solvents for your cleaning.
- Do not operate the product under the following conditions:
– Extremely hot, cold or humid environment.
– Areas susceptible to excessive dust and dirt.
– Near any appliance generating a strong magnetic field.
Chapter 1 Product Introduction
Overview
The SK-150P-A1 series is a 15” touchscreen monitor that builds to withstand
commercial-grade open frame monitor, with a stylish thin cable management
bracket and versatile
design SK-150P-A1 is an exceptional choice for applications for all business
sectors and is well suited for point-of-sale, point-of-information, point-of-
service and interactive signage.
Feature
- Cable management bracket design for easy organize cable.
Specifications
LCD Touch Panel
Size| 15″ TFT LCD
Brightness| 350 cd/m2 (Non-touch screen) 315 cd/m2(P-cap touch)
Number of Pixels| 1024 (H) x 768 (V)
Touch Type| P-CAP/ 10 points
Environment
Certificate| CE • FCC – UL/cUL
Compliance| Front Panel IP65 Compliant, Rear IPX1
Operating Temperature| 0°C – 40°C
Storage Temperature| -20°C – 60°C
Operating Humidity| 20% – 80% RH, non-condensing
Mounting| VESA 100 mm x 100 mm
Dimension (W x H x D)| 337.4 x 265.4 x 44.3 mm
Net Weight| 2.7 kg
Gross Weight| 4 kg
Block Diagram
Interface Connectors
Power Connector
The DC power via an external 12V Adapter provides it
Video Signal Connector
VGA
The video signal is input via a D-type 15-pin female connector.
Connector Pin Assignment:
Pin| Signal
1| RED
2| GREEN
3| BLUE
4| NC
5| GND
6| RED_RTN
7| GREEN RTN
8| BLUE_RTN
9| +5V
10| GND
11| NC
12| SDA
13| HSYNC
14| VSYNC
15| SCL
Display Port(1.2a)
Pin| Signal| Pin| Signal
1| ML_Lane 0(p) Data° +| 11| Signal ground
2| Signal ground| 12| ML Lane 3(n) Data3 –
3| ML Lane 0(n) Data° –| 13| Signal ground
4| ML_Lane 1(p) Data1 +| 14| Signal ground
5| Signal ground| 15| AUX CH(p) AUX + Signal for Auxiliary Channel
6| ML_Lane 1(n) Data1 –| 16| Signal ground
7| ML_Lane 2(p) Data2 +| 17| AUX CH(n) AUX – Signal for Auxiliary Channel
8| Signal ground| 18| Hot Plug
9| ML Lane 2(n) Data 2 –| 19| DP PWR Return
10| ML Lane 3(p) Data3 +| 20| DP PWR
HDMI(1.3) (compatible with
HDMI1.4)
Pin| Signal| Pin| Signal
1| TMDS Data2+| 11| TMDS Clock Shield
2| TMDS Data2 Shield| 12| TMDS Clock-
3| TMDS Data2—| 13| CEC
4| TMDS Data1+| 14| Reserved (N.C. on device)
5| TMDS Data1 Shield| 15| SCL
6| TMDS Data1—| 16| SDA
7| TMDS DataO+| 17| DDC/CEC Ground
8| TMDS data Shield| 18| +5V Power
9| TMDS data—| 19| Hot Plug Detect
10| TMDS Clock+| |
USB Connector
Pin| Signal| Pin| Signal
1| VCC| 3| D+
2| D-| 4| GND
RJ11 Connector (for Remote Key) (option)
Pin| Signal| Pin| Signal
1| MENU| 4| SELECT
2| UP| 5| POWER
3| DOWN| 6| GND
Package Overview
Warming!
This product is intended to be supplied by a Listed Power Adapter or DC power
source, rated 12Vdc, 2.5A minimum, Tma = 40 degrees C minimum, and the
altitude of operation = 3048m minimum. If it needs further assistance with
purchasing the power source, please contact to MicroTouch for further
information.
Chapter 2
About VESA Mount
The SK-150P-A1 series conform to the “VESA Flat Display Mounting Interface
Standard” which defines a physical mounting interface for touch monitor and
corresponds with the standards of touch monitor mounting devices. The VESA
mount is located on the back of this unit. Warming!
Please select the MicroTouch original screws!
The distance between the back cover surface and the bottom of the screw hole
is 8 mm. Please use four M4 screws diameter with 8-10mm proper length to mount
your monitor.
Note: The mounting stand must be able to support at least 7.67 lbs (3.48
Kg).
On-Screen Display
OSD Key | Menu off status | Menu on status |
---|---|---|
MENU | Menu appears | Menu disappear/ return to the main item |
▲ | Brightness | Main item select up/ Adjust up |
▼ | Contrast | Main item select down/ Adjust down |
SELECT | Enter/Select sub-item function | |
Power On/Off |
-
Press the “MENU” button to pop up the “on-screen menu” and press the “Up” or “Down” button to select among the four functions in the main menu.
-
Choose the adjustment items by pressing the “SELECT ” button.
-
Adjust the value of the adjustment items by pressing the “Up” or “Down” button.
-
With the OSD menu on the screen, press the “ Menu” button to return to the main menu or exit OSD.
-
The OSD menu will automatically close if you have left it idle for a preset time.
-
To Lock / Unlock the OSD / Power menu buttons, press “Menu” and “Minus” at the same time to select.
OSD / Power the Lock / Unlock function.
Please note:
a. When the OSD Lock function is selected, this indicates that all the buttons except the “power” button are now disabled.
b. When the Power Lock function is selected, this indicates that the power key is disabled; the user can not turn off the monitor by the “Power” key. -
To disable the touch function, press the “Menu” and “Enter” keys, at the same time.
-
To enable the touch function, press the “Menu” and “Enter” Key, at the same time for five seconds.
-
Press the power key button, there will be an OSD window pop up to ask if it should be going off. If press the power key in five seconds, the monitor power will be off. If don’t press the power key in five seconds, the OSD window will be gone and return to the normal status instead.
-
Direct input select function.
a. Normal:Press and keep pressing the “Select” key for 3 seconds, will change to pop up “source select” OSD.
b. Sleep status:Press and keep pressing the “Select” key for 1 second, will change to pop up “source select” OSD. -
Factory mode: Press the “MENU” button to pop up the “on-screen menu” and select the “Option” icon in the “Factory” item, key in passwords “3”, “3”, “3”, “3” into factory mode.
-
Burn-in mode: In Factory, mode select the “Burn In” item into Burin-in mode (unplug the signal cable or do not enter the signal source).
-
Work time: In factory mode, displays monitor the work time counting in hours.
OSD Function Description
Item | Content | Default |
---|---|---|
Contrast | The monitor luminance level control. | 50 |
Brightness | The monitor backlight level control. | 100 |
H-Positon | Moving screen image horizontal position to left or right. | NA |
V-Positon | Moving screen image vertical position to up or down. | NA |
Phase | The screen image horizontal dot clock adjustment. | NA |
Clock | The screen image pixel phase adjustment. | NA |
Auto Adjust | Fine-tune the image to full screen automatically. | NA |
OSD Timeout | OSD auto-disappear time selection. | 15 |
Reset | Factory default value restored. | NA |
OSD Language | OSD menu language selection. |
( English, French, Deutsch, Italian, Spanish, Japanese, Traditional Chinese,
and Simplified Chinese)| English
Source Select| Select Input function.(Auto, VGA, HDMI, DP)| Auto
Factory| Factory mode-related adjustment items.| NA
Timing Table Chart
Mode | NO | Resolution | H-Freq. (KHz) | Band Width (MHz) | Polarity |
---|---|---|---|---|---|
H | V | ||||
1 | 102 | 720×400 70Hz | 31. | 28. | |
2 | 103 | VGA 640×480 60Hz | 31. | 25. | |
3 | 182 | MAC 640×480 66Hz | 35 | 30. | |
4 | 173 | 640×480 72Hz | 38. | 32. | |
5 | 109 | 640X480 75Hz | 38. | 32. | |
6 | 104 | 800×600 56Hz | 35. | 36 | 1- |
7 | 116 | 800×600 60Hz | 38. | 40 | + |
8 | 110 | 800×600 72Hz | 48. | 50 | + |
9 | 117 | 800×600 75Hz | 47. | 50. | + |
10 | 108 | 832×624 (74.55Hz) | 50. | 57. | |
11 | 118 | 1024×768 (60.0 Hz) | 48. | 65 | |
12 | 157 | 1024×768 (70.0 Hz) | 56. | 75 | |
13 | 141 | 1024×768 (75.0 Hz) | 60. | 79. | + |
EDID Data
VGA
The monitor assembly shall provide a display communications channel that
conforms to VESA DDC2B hardware requirements. This configuration shall contain
the 128-byte EDID file as specified by VESA EDID Standard
DP/HDMI
The monitor assembly shall provide a display communications channel that
conforms to VESA DDC2B hardware requirements. This configuration shall contain
the 256-byte EDID file as specified by VESA EDID Standard
Dimension
Front View
Side View
Rear View
Equipment name: Touch LCD Monitor Type designation (Type): SK-150P-A1
Unit| Restricted substances and their chemical symbols
Lead (Pb)| Mercury (Hg)| Cadmium (Cd)| Hexavalent chromium (Cr5)|
Polybrominated biphenyls
(PBB)| Polybrominated diphenyl ethers (PBDE)
Plastic Parts| CD| O| O| O| O| O
Metal Parts| —| O| O| O| O| —
Cable component| —| O| O| O| O| O
LCD Panel| —| O| O| O| O| O
Touch Panel| —| O| O| O| O| O
PCB| —| O| O| O| O| O
Software| O| O| O| O| O| O
Note 1: -Exceeding 0.1 wt °/0″ and ‘exceeding 0.01 wt °A)” indicate that the
percentage content of the restricted substance exceeds the reference
percentage value of the present condition.
Note 2: “O” indicates that the percentage content of the restricted substance
does not exceed the percentage of the reference value of presence
Note 3: The “-” indicates that the restricted substance corresponds to the
exemption.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>