MicroTouch DT-150P-M1 Medical-Grade Monitor User Manual

June 6, 2024
MICROTOUCH

MicroTouch DT-150P-M1 Medical-Grade Monitor

Overview

The DT-150P-M1 series is a 15” touchscreen monitor that builds to withstand a commercial-grade open frame monitor, with a stylish thin cable management bracket and versatile design DT-150P-M1 is an exceptional choice for applications for all business sectors and well suited for point-of-sale, point-of-information, point-of-service and interactive signage.

Feature

  • Cable management bracket design for easy organizes cable.

Specifications

LCD Touch Panel

Size| 15” TFT LCD


Brightness

| 350 cd/m2 (Non-touch screen)

297 cd/m2 (P-cap touch with AG Coating)

Number of Pixels| 1024 (H) × 768 (V)
Touch Type| P-CAP/ 10 points
Environment
Certificate| CE, CB, FCC, UL, CCC, RoHS,

IEC60601-1-2 4th edition compliant

Compliance| Front Panel IP54
Operating Temperature| 0°C ~ 40°C
Storage Temperature| -20°C ~ 60°C
Operating Humidity| 20% ~ 80% RH, non-condensing
Mounting| VESA 100 mm x 100 mm
Dimension (W x H x D)| 337.4 mm x 304.2 mm x 200.9 mm
Net Weight| 4.4 kg
Gross Weight| 6 kg

Block Diagram

MicroTouch DT-150P-M1 Medical-Grade Monitor-
fig1

Interface Connectors

MicroTouch DT-150P-M1 Medical-Grade Monitor-
fig2

Power Connector

The DC power via external 12V Adapter provide it

Video Signal Connector

VGA
The video signal input via D-type 15-pin female connector. Connector Pin Assignment:




VGA

The video signal input via D-type 15-pin female connector.

Connector Pin Assignment:


Pin| Signal
1| RED
2| GREEN
3| BLUE
4| NC
5| GND
6| RED_RTN
7| GREEN_RTN
8| BLUE_RTN
9| +5V
10| GND
11| NC
12| SDA
13| HSYNC
14| VSYNC
15| SCL

Display Port(1.2a)




Display Port(1.2a)


Pin| Signal| Pin| Signal
1| ML_Lane 0(p) Data0 +| 11| Signal ground
2| Signal ground| 12| ML_Lane 3(n) Data3 –
3| ML_Lane 0(n) Data0 –| 13| Signal ground
4| ML_Lane 1(p) Data1 +| 14| Signal ground
5| Signal ground| 15| AUX_CH(p) AUX + Signal for Auxiliary Channel
6| ML_Lane 1(n) Data1 –| 16| Signal ground
7| ML_Lane 2(p) Data2 +| 17| AUX_CH(n) AUX – Signal for Auxiliary Channel
8| Signal ground| 18| Hot Plug
9| ML_Lane 2(n) Data 2 –| 19| DP_PWR Return
10| ML_Lane 3(p) Data3 +| 20| DP_PWR

HDMI(1.3) (compatible with HDMI1.4)





HDMI(1.3) (compatible with HDMI1.4)


Pin| Signal| Pin| Signal
1| TMDS Data2+| 11| TMDS Clock Shield
2| TMDS Data2 Shield| 12| TMDS Clock–
3| TMDS Data2–| 13| CEC
4| TMDS Data1+| 14| Reserved (N.C. on device)
5| TMDS Data1 Shield| 15| SCL
6| TMDS Data1–| 16| SDA
7| TMDS Data0+| 17| DDC/CEC Ground
8| TMDS Data0 Shield| 18| +5V Power
9| TMDS Data0–| 19| Hot Plug Detect
10| TMDS Clock+| |

Signal Connector



USB Connector


Pin| Signal| Pin| Signal
1| VCC| 3| D+
2| D-| 4| GND

RJ11 Connector (for Remote Key) (option)



RJ11 Connector (for Remote Key) (option)


Pin| Signal| Pin| Signal
1| MENU| 4| SELECT
2| UP| 5| POWER
3| DOWN| 6| GND

Package Overview

MicroTouch DT-150P-M1 Medical-Grade Monitor-
fig8

  • LCD Display
  • Power Cord
  • DC Power Supply
  • HDMI Cable
  • VGA cable
  • USB cable (A to B)
  • M3 screw
  • Zip bag

Warming!

This product is intended to be supplied by a Listed Power Adapter or DC power s ource, rated 12Vdc, 2.5A minimum, Tma = 40 degree C minimum, and the a ltitude of operation = 3048m minimum. If it needs further assistance with purc hasing the power source, please contact to MicroTouch for further information.

**About VESA Mount

MicroTouch DT-150P-M1 Medical-Grade Monitor-
fig9**

The DT-150P-M1 series conform to the “VESA Flat Display Mounting Interface Standard” which defines a physical mounting interface for touch monitor, and corresponding with the standards of touch monitor mounting devices. The VESA mount is located on the back of this unit.

Warming!

Please select the MicroTouch original screws! The distance between the back cover surface and the bottom of the screw hole is 8 mm. Please use four M4 screws diameter with 8-10mm proper length to mount your monitor.
Note: The mounting stand must be able to support at least 7.67 lbs (3.48 Kg).

On-Screen Display

OSD

Key

| ****

Menu off status

| ****

Menu on status

---|---|---
MENU| Menu appear| Menu disappear/ return to main item
▲| Brightness| Main item select up/ Adjust up
▼| Contrast| Main item select down/ Adjust down
SELECT| Enter/Select sub-item function
****| Power On/Off

  1. Press the “MENU” button to pop up the “on-screen menu” and press “Up” or “Down” button to select among the four functions in the main menu.

  2. Choose the adjustment items by pressing the “SELECT ” button.

  3. Adjust the value of the adjustment items by pressing the “Up” or “Down” button.

  4. With the OSD menu on screen, press “ Menu” button to return main menu or exit OSD.

  5. The OSD menu will automatically close, if you have left it idle for a pre-set time.

  6. To Lock / Unlock the OSD / Power menu buttons, press “Menu” and “Minus” at the same time to select. OSD / Power the Lock / Unlock function.
    Please note:

  7. When the OSD Lock function is selected, this indicates that all the buttons except “power” button are now disabled.

  8. When the Power Lock function is selected, this indicates that the power key is disabled; user can not to turn off the monitor by “Power” key.

  9. To disable the touch function, press “Menu” and “Enter” Key, at the same time.

  10. To enable the touch function, press “Menu” and “Enter” Key, at the same time for five seconds.

  11. Press the power key button, there will be an OSD window pop up to ask if it should be going off. If press the power key in five seconds, the monitor power will be off. If don’t press the power key in five seconds, the OSD window will be gone and return to the normal status instead.

  12. Direct input select function.

  13. Normal:Press and keep pressing “Select” key for 3 seconds, will change to pop up “source select” OSD.

  14. Sleep status:Press and keep pressing “Select” key for 1 seconds, will change to pop up “source select” OSD.

  15. Factory mode: Press the “MENU” button to pop up the “on-screen menu” and select “Option” icon in “Factory” item, key in password “3”,”3″,”3″,”3″ into factory mode.

  16. Burn-in mode: In Factory mode to select “Burn In” item into Burin-in mode (unplug signal cable or do not enter the signal source).

  17. Work time: In factory mode, displays monitor the work time counting in hours.

OSD Function Description

Item Content Default
Contrast The monitor luminance level control. 50
Brightness The monitor backlight level control. 100
H-Positon Moving screen image horizontal position to left or right. NA
V-Positon Moving screen image vertical position to up or down. NA
Phase The screen image horizontal dot clock adjustment. NA
Clock The screen image pixel phase adjustment. NA
Auto Adjust Fine-tune the image to full screen automatically. NA
Color Temp Color temperature selection.

(9300K, 6500K, 5500K, 7500K, User)

| USER
Medical models: Sharpness| Adjust the screen sharpness.| 50
Medical models: Gamma| Gamma / DICOM function mode. (Native, 1.8, 2.2, DICOM)| Native
OSD Timeout| OSD auto-disappear time selection.| 15
Medical models: OSD Positon| Moving OSD menu position.| User
OSD H-Positon| Moving OSD menu horizontal position to left or right.| 50
OSD V-Positon| Moving OSD menu vertical position to up or down.| 50
Reset| Factory default value restored.| NA


OSD Language

| OSD menu language selection.

( English, French, Deutsch, Italian,Spanish, Japanese, Traditional Chinese and Simplified Chinese)

| ****

English

Source Select| Select Input function.(Auto, VGA,HDMI,DP)| Auto
Medical models: Display port| Display current resolution related information.| NA
Medical models: Lum Preset| The monitor backlight function quick mode. (Set1, Set2, Set3, User)| User
Factory| Factory mode related adjustment items.| NA

Timing Table Chart


Mode

| ****

NO

| ****

Resolution

| H-Freq. (KHz)| Band Width (MHz)| Polarity
---|---|---|---|---|---
H| V
1| 102| 720×400 70Hz| 31.47| 28.322| -| +
2| 103| VGA 640×480 60Hz| 31.47| 25.175| -| -
3| 182| MAC 640×480 66Hz| 35| 30.24| -| -
4| 173| 640×480 72Hz| 37.86| 31.5| -| -
5| 109| 640X480 75Hz| 37.5| 31.5| -| -
6| 104| 800×600 56Hz| 35.16| 36| +| +
7| 116| 800×600 60Hz| 37.88| 40| +| +
8| 110| 800×600 72Hz| 48.077| 50| +| +
9| 117| 800×600 75Hz| 46.875| 49.5| +| +
10| 108| 832×624 (74.55Hz)| 49.722| 57.28| -| -
11| 118| 1024×768 (60.0 Hz)| 48.363| 65| -| -
12| 157| 1024×768 (70.0 Hz)| 56.476| 75| -| -
13| 141| 1024×768 (75.0 Hz)| 60.02| 78.75| +| +

EDID Data

VGA
The monitor assembly shall provide a display communications channel that conforms to VESA DDC2B hardware requirements. This configuration shall contain the 128-byte EDID file as specified by VESA EDID Standard
DP/HDMI
The monitor assembly shall provide a display communications channel that conforms to VESA DDC2B hardware requirements. This configuration shall contain the 256-byte EDID file as specified by VESA EDID Standard

Dimension

Front ViewMicroTouch DT-150P-M1 Medical-Grade Monitor-
fig11

Side View

Rear View

Declaration of the Presence Condition of the Restricted Substances Marking

Note 1: 〝Exceeding 0.1 wt %〞and〝exceeding 0.01 wt %〞indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.。
Note 2: 〝○〞indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence.
Note 3: The〝−〞indicates that the restricted substance corresponds to the exemption.

Compliance Information

For FCC (USA)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For IC (Canada)
CAN ICES-3(B)/NMB-3(B)
For CE (EU)
The device complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU