FORTIN EVO-ONE All-In-One Data Interface Remote Starter/Alarm Installation Guide

June 6, 2024
FORTIN

FORTIN EVO-ONE All-In-One Data Interface Remote Starter/Alarm

Installation

WIRING / CONNECTION GUIDE

FORTIN EVO-ONE All-In-One Data Interface Remote StarterAlarm
Fig1

PROGRAMMING REMOTE TRANSMITTER(S)

The system can learn up to a maximum of 4 transmitters. Any transmitters can be stored in more than 1 memory slot. When a 5th transmitter is learned the 1st remote is erased (FIFO). *Valet switch sold separatelyFORTIN EVO-ONE
All-In-One Data Interface Remote StarterAlarm Fig2

FUNCTION PROGRAMMING

FORTIN EVO-ONE All-In-One Data Interface Remote StarterAlarm
Fig3

FUNCTION

FORTIN EVO-ONE All-In-One Data Interface Remote StarterAlarm
Fig6

MANUAL TRANSMISSION SEQUENCE FOR COMPATIBLE VEHICLES ONLY

FORTIN EVO-ONE All-In-One Data Interface Remote StarterAlarm
Fig4

TO ENABLE COLD START MODE Press and release the AUX button, within 12 seconds simultaneously press and and hold the LOCK and START buttons for 1 second. The parking lights will flash once.

TO DISABLE COLD START MODE Press and release the AUX button, within 12 seconds simultaneously press and and hold the LOCK and START buttons for 1 second. The parking lights will flash twice.

  • Put the Remote-Starter/alarm into Valet
  • Remote-Start the vehicle
  • Open the hood
  • Press the brake pedal
  • Turn the key to the ignition position.
  • Disable Ready Mode (manual transmission).

DISARM / ENTER / EXIT VALET MODE

FORTIN EVO-ONE All-In-One Data Interface Remote StarterAlarm
Fig5

REMOTE START DIAGNOSTICS

Parking Lights flashes (before starting) :

  • 3x Ready mode disabled

  • 4x Valet mode activated (The LED is on)

  • 5x Hood open
    Parking Lights flashes (after Shutdown) :

  • Normal stop (Brake, Park Brake)

  • Runtime expired or shut down by transmitter

  • No tachometer signal

  • Hood open

  • Over crank threshold (8 seconds)

ALARM DIAGNOSTICS

Parking Lights flashes (after disarm) :

  • 3x Door open – zone 3
  • 4x Shock sensor – zone 4
  • 5x Hood open – zone 5
  • 6x Trunk open – zone 6

WARNING

NOTICE The manufacturer will accept no responsibility for any electrical damage resulting from improper installation of the product, including either damage to the vehicle itself or to the remote-starter module. This module must be installed by a certified technician including all of the supplied safety devices. Please note that this guide has been written for trained professional technicians, a certain level of skills and knowledge is therefore assumed. Please review the Installation Guide carefully before beginning any work.
WARNING By default this system is setup for vehicles with a manual transmission. For vehicles with an automatic transmission, the safety wire loop on the main unit must be cut. Before proceeding to the installation, make sure that the vehicle does not attempt to start when the vehicle is in the “drive” or “reverse” position. If an automatic transmission vehicle starts when the transmission is in gear, ensure that the safety wire loop on the unit is not cut. Once the safety wire loop is cut, the system is considered an automatic transmission remote-starter indefinitely. Once a loop is cut all warranties, guarantees, and liability is immediately void if the unit is installed on a manual transmission vehicle. Neither the manufacturer or distributor of this module is responsible of damages of any kind indirectly or directly caused by this module, except for the replacement of this module in case of manufacturing defects. This module must be installed by a qualified technician. This instruction guide may change without notice. To download the installation guide, user guide, or the latest quick installation guide, visit: WWW.FORTIN.CA Technical support: TEL: 514-255-4357 / 1-877-336-7797
Copyright © 2014-2021, FORTIN AUTO RADIO INC ALL RIGHTS RESERVED MADE IN CANADA