CANARM DCQ014-W Ceiling Fan Wall-Mounted Control Instruction Manual
- June 5, 2024
- CANARM
Table of Contents
CANARM DCQ014-W Ceiling Fan Wall-Mounted Control
****
Installation Instruction
SAFETY PRECAUTIONS:
- Read carefully and retain the instruction.
- Please note that all fixed wiring appliances should be installed by a qualified electrician.
- To avoid possible electrical shock, be sure electricity is turned off at the main fuse box or circuit panel before wiring.
- Do not mount wall control near heat-producing equipment.
- Wall-mounted control only with ceiling fan capacitor speed control only.
- Ensure no bare wires are exposed outside the connectors.
- For use only with CSA master contract 157644,Models CP48D,CP56D,CP60D,CP48DW, CP56DW,CP60DW.
INSTALLATION INTRUCTIONS
- Disconnect the power and remove the existing wall plate and switch.
- If your ceiling fan is equipped with a pull chain switch, make sure set the speed control at the highest speed and light kit at power on before installing the wall control.
- Set the knob and Power switch of the wall-mounted control in the off (0) position.
Connect the wires as shown.
- Connect BLACK wall control wire (marked with “AC in L”) to the BLACK wire from the main power on the wall outlet box.
- Connect WHITE wall control wire (marked with “AC in N”) to the WHITE wire from the main power on the wall outlet box.
- Connect BLACK wall control wire (marked with “TO Motor L”) to the BLACK wire that connected to the BLACK wire of the fan from ceiling.
- Connect WHITE wall control wire (marked with “TO Motor N”) to the WHITE wire that connected to the WHITE wire of the fan from ceiling.
- Carefully push wire nuts into the UL or CSA-approved outlet box after connections.
- Install the control to the outlet box by 2 screws.
- Push firmly the front cover into the wall unit.
- Load: fan 3.0A (Max.)
- Max Loading of fan: 5
WIRING DIAGRAM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>