Notice : 10S users search Aroma IOT on the Apple Store to download. Android users scan the QR code to download, 10S users also can scan to download.

Tips: Bluetooth signal receiving light, blue indicator light. When the APP is connecting and successfully connected, the Bluetooth light is always on. A command is sent by the APP each time, the blue light flashes three times, indicating the setting is successful. If no command is sent for more than 10 minutes during successful connection, Bluetooth will automatically disconnect. In non-Bluetooth connection status, the blue light is off.

Atomization level and working parameters

  • Working time /single time(s): 0s-200s (adjustable)
  • Interval time/single time(s): 1 0s-200s (adjustable)
  • Fan gear/single time: low gear, high gear
  • Working time/date (d): (Monday to Sunday) (Monday to Saturday) (Monday to Friday); (Monday) (Tuesday) (Wednesday) (Thursday) (Friday) (Saturday) (Sunday);{Monday to Wednesday) {Tuesday to Thursday) (Saturday to Sunday); (Monday, Wednesday and Friday) {Tuesday, Thursday and Saturday)

Instruction

Device indicator light/ Button function

Guangzhou Tang Mei Environmental Protection Technology 500B Aroma Diffuser
fig 1

APP operation demonstration:Guangzhou Tang Mei Environmental Protection
Technology 500B Aroma Diffuser fig 2

Note : the new user downloads the app first, use mobile number or email to register, then sign in. new user downloads the app first, use mobile number or email to register, then sign in.Guangzhou Tang Mei Environmental
Protection Technology 500B Aroma Diffuser fig 3

Note : open Bluetooth first to search for the device name, then connect the device.

APP operation demonstration:

Guangzhou Tang Mei Environmental Protection
Technology 500B Aroma Diffuser fig 4Guangzhou Tang Mei Environmental
Protection Technology 500B Aroma Diffuser fig 5Guangzhou Tang Mei Environmental
Protection Technology 500B Aroma Diffuser fig 11

Parameter

  • Model No: 500 B
  • Product Size: 14473186mm
  • Voltage: DC12V
  • Power: SW
  • Coverage: 300-500 m3
  • Capacity: 200ml+
  • Product weight: 1 KGGuangzhou Tang Mei Environmental Protection Technology 500B Aroma Diffuser fig 6Guangzhou Tang Mei Environmental Protection Technology 500B Aroma Diffuser fig 7 Guangzhou Tang Mei Environmental Protection Technology 500B Aroma Diffuser fig 8
  1. First use the key to open the cover.
  2. Then take out the essential oil bottle.
  3. Fill oil inside the bottle,fix the bottle into device,close the cover.
  4. Plug in,set its working time and let it work.

Button operation demonstration:

Button function:

  • Short press: adjust the fan gear, the gears are: low gear, high gear, off.
  • Long press: the device enters into test operation function, works for 15 seconds.

Indicator light display

Blue indicator light,bluetooth signal receiving light. When the APP is connecting and successfully connected, the Bluetooth light is always on. A command is sent by the APP each time, the blue light flashes three times, indicating the setting is successful. If no command is sent for more than 10 minutes during successful connection, Bluetooth will automatically disconnect. In non-Bluetooth connection status, the blue light is off. Red indicator light, the device working light. When the device is in operation, the red light flashes once every 15 seconds.

Warning:

  1. After installation, please keep the machine vertical. Leaning or Flipping will cause oil leakage and damage the machine.
  2. If you are not a technician, you must not modify, disassemble or repair the — device. If the device breaks down, please contact our technical staff in time.Guangzhou Tang Mei Environmental Protection Technology 500B Aroma Diffuser fig 10

Clean the device

When the following happens, the device needs to be cleaned

  1. You are going to change another essential oil to use;
  2. The amount of atomizing is getting weaker and weaker;

Cleaning steps

  1. Take off the atomizer head , tak e out the oil bottle;
  2. Pour the appropriate amount of alcohol into the oil bottle, install it on the device to work 5-10 times to prevent cross-odor;
  3. Cleaning is finished after oil bottle drying.

Troubleshooting

Before preparing to repair the machine, first try to solve the problem according to the following methods.

Problem Solution
No fogging 1. Check whether the air outlet seal is damaged.

2. Check whether the device is in “OFF” state.
3. Check whether the air pump is working, or replace the atomizing nozzle.
4.  Check whether the air pipe connected to the air pump is sealed or damaged.
Small fog| 1.  Check whether the air outlet seal is damaged.
2. Check whether the atomizing nozzle is blocked.
3.  Check whether the atomizing nozzle inside is loose, or replace the atomizing nozzle.
Oil leak| 1.Check whether the atomizing nozzle is damaged.
2.Check whether the gasket damaged need to replace.
3.Check whether the essential oil bottle and the atomizing head are parallel or tighten.
Abnormal noise| 1.  Check if the air pump is loose, then fix the air pump again.

2.  Check whether the air pump is damaged, replace with a new a,r pump.

After-sales service

  • The equipment is guaranteed within one year from the date of sale, but it does not guarantee the vulnerable parts such as the casing, wires and external pipes, and the damage caused by man-made or accidents is not covered by the warranty. If the warranty period is exceeded, the maintenance will be paid.
  • If you encounter any after-sales problems, you can contact the authorized sales service providers in various regions, or contact our sales center directly.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter.
Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. in portable exposure condition without restriction.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals