Gude GS, GSX Series Submersible Pump for Dirty Water Instructions
- June 3, 2024
- Gude
Table of Contents
GS, GSX Series Submersible Pump for Dirty Water
Instruction Manual
DELIVERED ITEMS
Please read the instructions carefully before starting the machine.
Technical Data
Read and understand the operating instructions before using the appliance. abide by all the safety measures stated in the service manual. act responsibly toward third parties. in case of any doubts about connection and operation refer please to our customer center
Specified Conditions of Use
The pump is solely used for drainage and for pumping into and out of
containers in the house, garden, farm, and agriculture and only for water.
Respecting technical data and safety precautions.
Do not use this product in any other way than stated for normal use. not
observing general regulations in force and instructions from this manual does
not make the manufacturer liable for damages.
The pump is not suited for long-run operation (e.g. as a circulation pump in
ponds or streams).
When used in this manner, its service life is curtailed correspondingly. in
these cases, then, use a time switch to secure sufficient idle periods between
cycles of operation.
Do not leave the pump unattended while in operation in order to prevent
subsequent damages caused by eventual malfunctions. Make sure to disconnect
the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a
pressure-boosting device.
Safety instructions
WARNING! electric shock!
There is a risk of an injury caused by electric shock! This device is not
intended for use by persons (including children) with limited physical,
sensory or mental capabilities or without the necessary lack of experience or
knowledge unless they are supervised by a person who is responsible for their
safety or was instructed by that person in how to use the device. children
should be supervised to ensure that they do not play with the device. always
keep children and unauthorized persons out of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RcD max.
stray current of 30ma). before putting it into operation, a qualified
electrician must check whether the electric safety measures required are in
place. any national regulations in this regard must be complied with. electric
connection to a socket. it is necessary to make sure the connecting socket was
not near water and humidity and that the plug was protected against humidity.
check the voltage. Technical data given on the type label must correspond with
the electric network voltage. Only use splash-proof extension cables approved
for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is
connected to the grid! check the cable and/or socket for damages before the
appliance putting into operation.
To avoid danger, a damaged mains supply pipe must be replaced by the
manufacturer. Do not under any circumstances attempt any repair yourself.
Protect the feeder cable from excessive temperatures, oil, and sharp edges.
Unplug the device prior to submersion, upon the termination of operation, in
the course of defect removal, and prior to performing maintenance procedures.
if the pump is in operation, neither people nor animals can be present or
plunged in the pumped liquid (e.g. pools, cellars, etc.). The pump must not in
any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent
subsequent damages caused by eventual malfunctions. Make sure to disconnect
the device from the grid if you do not plan on using it. The temperature of
the drained liquid must not exceed +35 °c. if the lubricant escapes the fluid
could become contaminated. if the pump is used in ponds, wells, etc., and
appropriate pumping stations, standards valid for pumps in the given country
must unconditionally be observed. The user is responsible to third parties if
a pump (dumping stations, etc.) is used.
Requirements for operating staff
The operating staff must carefully read the Operating instructions before
using the appliance.
Qualification: apart from the detailed instructions by a professional, no
special qualification is necessary for appliance use.
Minimum age: Persons over 16 years of age can only work on the appliance. an
exception includes youngsters trained in order to reach knowledge under the
supervision of the trainer during occupational education.
Training: Using the appliance only requires corresponding training by a
professional or the Operating instructions. no special training is necessary.
Emergency procedure
conduct a first-aid procedure adequate to the injury and summon qualified
medical attendance as quickly as possible. Protect the injured person from
further harm and calm them down. for the sake of an eventual accident, in
accordance with Din 13164, a workplace has to be fitted with a first-aid kit.
it is essential to replace any used material in the first-aid kit immediately
after it has been used. if you seek help, state the following pieces of
information:
- accident site
- accident type
- number of injured person
- injury type(s)
Maintenance
before carrying out any work on the machine, disconnect the plug from the
socket.
Prior to every use, visually check the machine to rule out any defects, in
particular on the power cable and the plug.
The machine must not be used under any circumstances if the machine or the
safety devices are damaged.
Refer all servicing to customer service. Use only original accessories and
original spare parts.
To ensure the long service life of the pump seal we recommend rinsing the pump
with clean water at regular intervals. During winter storing, it is necessary
to make sure there is no water in the appliance as the frost could damage the
appliance. Prior to transportation, it is necessary to unplug the pump from
the grid! The device has to be completely emptied and stored with frost-proof
protection. adhesion of mechanical seals can be prevented if you rinse the
pump with the appropriate oil (for example, vegetable oil).
Only a regularly maintained and treated appliance can serve as a satisfactory
aid. insufficient maintenance and care can lead to unforeseen accidents and
injuries.
Guarantee
The warranty period of 12 months applies to commercial use and 24 months
applies to private use and commences on the day of purchase of the device.
The guarantee solely covers inadequacies caused by material defects or
manufacturing defects. An original payment voucher with the date of the sale
needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorized use such as appliance
overloading, use of violence, or damage as a result of any unauthorized
interference caused by foreign items. failing to follow the operating and
assembly instructions and common wear are also not included in the guarantee.
GÜDe cannot be held responsible for damages incurred as a consequence of unqualified installation or unskilled handling of the pump. The device has to be checked on a regular basis to ensure perfect functioning. let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:
- Unprofessional repairs executed by unauthorized service centers;
- Use in conflict with the designed purpose, or failure to observe the use as designed;
- Pump overload with a continuous run;
- Damage as a result of icing or any other fault caused by climatic influences; identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
service
Do you have any technical questions? any claim? Do you need any spare parts or
operating instructions? We will quickly help you without needles bureaucracy
on our web pages at www.guede.com in the Servicing
part.
Please help us be able to help you. in order to identify your device in case
of claim we need the serial no., product no., and year of production. all this
data can be found on the type label. Please enter it here for future
reference:
Serial no.:
art. no:
Year of production:
| Read the Operating instructions
---|---
before carrying out any work on the machine, disconnect the plug from the
socket.
cable pulling/transport prohibited
Staying in the transportation medium prohibited
Warning against dangerous electric voltage
Warning against automatic starting
accessory – not included in standard equipment, available as an accessory.
any damaged or disposed of electric or electronic devices must be delivered to
appropriate collection centers.
Protect against humidity
This side up
Inspection and maintenance plan
Time interval | Time interval | Any other details |
---|---|---|
as needed | as needed | function check of the floating switch |
Failures – causes – removal
Failures | Causes | Removal |
---|---|---|
the engine does not start | no power supply. |
blocked pump wheel
floating switch in the shutdown position| check the voltage
Visually inspect the pump wheel for Foreign
objects check the water level
The pump does not suck| Pump without water Water level too low blocked pump
wheel| let the air bubbles release 4 Switch the pump off, the water level must
go up.
Remove the obstruction
Thermal detector switching the pump off
5| Plugged strainer
The water temperature is too high
The pump runs continuously at maximum pressure.| clean the strainer and let
the pump cool down
Reduce the water temperature
Make more breaks
insufficient amount of
water pumped| Dirty strainer
The water level quickly drops down Maximum head of delivery exceeded broken
piping| clean the strainer ensures sufficient inflow check the transport line
3 check the transport line
GÜDe Gmbh & co. kG
birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
fax.: +49-(0)7904/700-250
eMail: info@guede.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>