Gude GS, GSX Series Submersible Pump for Dirty Water Instructions

June 3, 2024
Gude

GS, GSX Series Submersible Pump for Dirty Water
Instruction ManualGude GS, GSX Series Submersible Pump for Dirty
Water

DELIVERED ITEMS

Gude GS, GSX Series Submersible Pump for Dirty Water - Figure
1

Please read the instructions carefully before starting the machine.

Gude GS, GSX Series Submersible Pump for Dirty Water - Figure
2Gude GS, GSX Series
Submersible Pump for Dirty Water - Figure 3Gude GS, GSX Series Submersible Pump for Dirty Water - Figure
4Gude GS, GSX Series
Submersible Pump for Dirty Water - Figure 5Gude GS, GSX Series Submersible Pump for Dirty Water - Figure
6Gude GS, GSX Series
Submersible Pump for Dirty Water - Figure 7Gude GS, GSX Series Submersible Pump for Dirty Water - Figure
8Gude GS, GSX Series
Submersible Pump for Dirty Water - Figure 9Gude GS, GSX Series Submersible Pump for Dirty Water - Figure
10

Technical Data

Gude GS, GSX Series Submersible Pump for Dirty Water - Figure
11

Read and understand the operating instructions before using the appliance. abide by all the safety measures stated in the service manual. act responsibly toward third parties. in  case of any doubts about  connection and operation refer please to our customer center

Specified Conditions of Use

The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm, and agriculture and only for water.
Respecting technical data and safety precautions.
Do not use this product in any other way than stated for normal use. not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams).
When used in this manner, its service life is curtailed correspondingly. in these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a pressure-boosting device.

Safety instructions

WARNING! electric shock!
There is a risk of an injury caused by electric shock! This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack of experience or knowledge unless they are supervised by a person who is responsible for their safety or was instructed by that person in how to use the device. children should be supervised to ensure that they do not play with the device. always keep children and unauthorized persons out of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RcD max. stray current of 30ma). before putting it into operation, a qualified electrician must check whether the electric safety measures required are in place. any national regulations in this regard must be complied with. electric connection to a socket. it is necessary to make sure the connecting socket was not near water and humidity and that the plug was protected against humidity. check the voltage. Technical data given on the type label must correspond with the electric network voltage. Only use splash-proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid! check the cable and/or socket for damages before the appliance putting into operation.

To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself. Protect the feeder cable from excessive temperatures, oil, and sharp edges. Unplug the device prior to submersion, upon the termination of operation, in the course of defect removal, and prior to performing maintenance procedures. if the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.). The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it. The temperature of the drained liquid must not exceed +35 °c. if the lubricant escapes the fluid could become contaminated. if the pump is used in ponds, wells, etc., and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed. The user is responsible to third parties if a pump (dumping stations, etc.) is used.

Requirements for operating staff

The operating staff must carefully read the Operating instructions before using the appliance.
Qualification:  apart from the detailed instructions by a professional, no special qualification is necessary for appliance use.
Minimum age:  Persons over 16 years of age can only work on the appliance. an exception includes youngsters trained in order to reach knowledge under the supervision of the trainer during occupational education.
Training:  Using the appliance only requires corresponding training by a professional or the Operating instructions. no special training is necessary.

Emergency procedure
conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. for the sake of an eventual accident, in accordance with Din 13164, a workplace has to be fitted with a first-aid kit. it is essential to replace any used material in the first-aid kit immediately after it has been used. if you seek help, state the following pieces of information:

  1. accident site
  2. accident type
  3. number of injured person
  4. injury type(s)

Maintenance

before carrying out any work on the machine, disconnect the plug from the socket.
Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.
The machine must not be used under any circumstances if the machine or the safety devices are damaged.
Refer all servicing to customer service. Use only original accessories and original spare parts.
To ensure the long service life of the pump seal we recommend rinsing the pump with clean water at regular intervals. During winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. adhesion of mechanical seals can be prevented if you rinse the pump with the appropriate oil (for example, vegetable oil).
Only a regularly maintained and treated appliance can serve as a satisfactory aid. insufficient maintenance and care can lead to unforeseen accidents and injuries.

Guarantee

The warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device.
The guarantee solely covers inadequacies caused by material defects or manufacturing defects. An original payment voucher with the date of the sale needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorized use such as appliance overloading, use of violence, or damage as a result of any unauthorized interference caused by foreign items. failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.

GÜDe cannot be held responsible for damages incurred as a consequence of unqualified installation or unskilled handling of the pump. The device has to be checked on a regular basis to ensure perfect functioning. let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:

  • Unprofessional repairs executed by unauthorized service centers;
  • Use in conflict with the designed purpose, or failure to observe the use as designed;
  • Pump overload with a continuous run;
  • Damage as a result of icing or any other fault caused by climatic influences; identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

service

Do you have any technical questions? any claim? Do you need any spare parts or operating instructions? We will quickly help you without needles bureaucracy on our web pages at www.guede.com in the Servicing part.
Please help us be able to help you. in order to identify your device in case of claim we need the serial no., product no., and year of production. all this data can be found on the type label. Please enter  it here for future reference:

Serial no.:
art. no:
Year of production:

Gude GS, GSX Series Submersible Pump for Dirty Water - icon
1| Read the Operating instructions
---|---
before carrying out any work on the machine, disconnect the plug from the socket.
cable pulling/transport prohibited
Staying in the transportation medium prohibited
Warning against dangerous electric voltage
Warning against automatic starting
accessory – not included in standard equipment, available as an accessory.
any damaged or disposed of electric or electronic devices must be delivered to appropriate collection centers.
Protect against humidity
This side up

Inspection and maintenance plan

Time interval Time interval Any other details
as needed as needed function check of the floating switch

Failures – causes – removal

Failures Causes Removal
the engine does not start no power supply.

blocked pump wheel
floating switch in the shutdown position| check the voltage
Visually inspect the pump wheel for Foreign
objects check the water level
The pump does not suck| Pump without water Water level too low blocked pump wheel| let the air bubbles release 4 Switch the pump off, the water level must go up.
Remove the obstruction
Thermal detector switching the pump off
5| Plugged strainer
The water temperature is too high
The pump runs continuously at maximum pressure.| clean the strainer and let the pump cool down
Reduce the water temperature
Make more breaks
insufficient amount of
water pumped| Dirty strainer
The water level quickly drops down Maximum head of  delivery exceeded broken piping| clean the strainer ensures sufficient inflow check the  transport line 3 check the transport line