Installing the BWA-QM30-FT Brackets
The required components included in the BWA-QM30-FTSS and BWA-QM30-FTAL bracket assemblies are:
- One SMBQM30 bracket
- One Phillips 1/4-28 x 1/2 flathead screw
- Four M2.5 socket head cap screws
- One thermal tape (BWA-BK-022 only)
The following items are recommended, but not included in the bracket or sensor kits:
- Loctite 410 (blue)
- Cleaning wipes
- 2 mm hex Allen wrench
- Phillips screwdriver
Install the BWA-QM30-FT Brackets Using Thermal Tape
This example uses a QM30VT2 with BWA-QM30-FTAL. The same steps can be applied for a QM30VT1 with BWA-QM30-FTAL or a QM30VT2-SS-9M with BWA-QM30-FTSS. The provided thermal tape or desired epoxy could be used by following these steps.
-
Clean the bracket and sensor.
-
Place the sensor on top of the bracket so the countersunk hole is covered by the sensor and the four corner holes align.
-
Screw the sensor to the bracket with the provided screws using a 2 mm Hex Allen wrench. The maximum torque for socket head screws is 0.5 N·m. Do not over tighten.
- Apply the thermal tape to the bracket.
- Turn sensor with bracket side faced up.
- Peel the clear liner off the thermal tape.
- Align and stick the thermal tape to the bracket with blue liner facing up.
- Peel off the blue side of the tape.
- Stick the bracket and sensor assembly to equipment.
- Apply pressure for 30 seconds to improve adhesion.
Install the BWA-QM30-FT Brackets Using a Flathead Screw
This example uses a QM30VT2 with BWA-QM30-FTAL for demonstration. The same steps can be applied for a QM30VT1 with BWA-QM30-FTAL or a QM30VT2-SS-9M with BWA-QM30-FTSS.
-
Clean bracket and sensor.
-
Tap a 1/4-28 x 1/2 hole into the surface of the equipment you want to monitor.
-
Put the flathead screw into the countersunk hole of the bracket.
-
Coat the threads in the mounting surface with the 410 series Loctite.
-
Screw the bracket into your drilled hole until the bracket is snug. The maximum torque for the flathead screws is 1 N·m. Do not over tighten.
-
Place the sensor on top of the bracket so the four corner holes align. Secure sensor to bracket with the provided screws using a 2 mm Hex Allen wrench.The maximum torque for socket head screws is 0.5 N·m. Do not over tighten.
Install the BWA-QM30-FM/CM Magnetic Round Mount Brackets
The required components included in the BWA-QM30-FMSS and BWA- QM30-CMAL bracket assemblies are:
- One bracket
- BWA-QM30-FMSS: Four M2.5 x 14 mm and four M2.5 x 16 mm socket head cap screws
- BWA-QM30-CMAL: Four M2.5 x 16 mm socket head cap screws
The following items are recommended, but not included in the bracket or sensor kits:
- Cleaning wipes
- 2 mm hex Allen wrench
This example uses a QM30VT2, but these steps can also be used on other QM30VT models. Brackets BWA-QM30-FMSS and BWA-QM30-CMAL are not included with the QM30VT sensor and must be purchased separately.
-
Clean the bracket and sensor.
-
Turn the bracket so the magnet is facing down.
-
Place the sensor on top of bracket, aligning the four corner holes.
-
Secure the sensor to the bracket using the screws for the model being installed.
The maximum torque for flathead screws is 0.5 N·m. Do not over tighten.
- Place the sensor on the equipment to be monitored.