RunCam SPLIT-HD Split HD User Manual
- June 5, 2024
- RunCam
Table of Contents
RunCam
Split HD
User Manual
Instruction Diagram
Lens Module Connection Diagram
Micro SD Card
Capacity up to 128GB; U3 recommended (2.7K50/1080P120 requires U3 or above; other solutions require U1 or above)
Please push the shield a little bit up with one hand like showed in above (step 1) and then press the SD card(step 2) with another hand to let the card pop out.
Basic Camera Operation
Powering On/Off| Short press the power button to turn on, long press 2S to
turn off
---|---
Standby Mode| Status light-Red LED always on
Mode Switching| Double-click the power button in standby mode to switch
between Lopp video and QR code Parameter Setting mode.
Video Mode| Status light-red LED flashes slowly at 1 second interval
Chnrr nress the power/shutter button to start/stop recording
QR Code Setting| status light-green LED always on
Use RUNCAM APP to enter RunCam Split HD entrance,
Set up and generate a QR code. Scan with camera in QR code mode QR code, it
will automatically switch to standby mode after
setting successfully. Status light red LED
HO Recording Firmware Update| Status light-red and green LEDs flash at the
same time
SD Card Issues| Status light-red LED flashes quickly at 0.5 second intervals
Lens Module Bad Connection| Status light-green LED flashes quickly at 0.5
second intervals
Power Supply and Remote UART Control Connection Diagram
Warning: Current Input ≥1A (Don’t powered by VTx)
Flight Controller UART Control
Preparation
· Firmware: BetaFlight Firmware (≥3.2.0),CleanFlight Firmware(≥2.1.0) , KISS
Firmware (≥1.3-RC30) or INAV Firmware (≥1.7.3).
· Any available UART interface on the Flight Controller
- Connect the RunCam Split HD with the UART interface of the Flight Controller
- Make the Flight Controller recognize the RunCam Split HD
For example, we connect the RunCam Split HD to the UART 5 interface on the Flight Controller: connect the Flight Controller to the computer, then open the configurator software of the Flight Controller. (Open up the configurator that matches the firmware you are running, Betaflight Configurator for Betaflight, Cleanflight Configurator for Cleanflight). In the Peripherals column of the line UART 5 (on the Ports tab), select Camera (RunCam Protocol) and click Save And Reboot.
3. Instructions of the functions of the camera and assigning transmitter
channels to them
In the Flight Controller Configurator, navigate to the Modes tab. There are new
CAMERA WI-FI, CAMERA POWER and CAMERA CHANGE modes
-
CAMERA POWER: start/stop the video. When in the OSD of the camera, this is used to move to the next menu item.
-
CAMERA CHANGE MODE: Switch between the recording mode and the QR code setting mode.
Assign any available channel to the function you need, for example: -
Assign the AUX2 to the CAMERA POWER, range 1900-2100
-
Assign the AUX3 to the CAMERA CHANGE MODE, range 1900-2100
4. Assign the channel to the switch of the controller
Please choose your Model on the controller, then access to the MIXER interface
and assign the channel to the switch of the controller. Take opentx 2.2.0 for
example, assign
the channels CH5, CH6 and CH7 to SA, SB and SD respectively
5. Test
Power the Flight Controller and the RunCam Split HD
- Set the SA to the bottom, the camera starts/stops the video
- Set the SD to the bottom, the camera switches among the two modes: video and OSD setting mode
Technical Support
Please visit: https://support.runcam.com
Parameter
Model | RunCam Split HD |
---|---|
Field of View(FOV) | 154° |
Horizontal Perspective | 124° |
Video Resolution | 2.71460fps/2.7Kg0rps (4:3) 1440P@60fps/1080PeD60fps |
FPV Resolution | 720P@60fps |
Video File Format | MP4 |
Image Sensor | SONY ( 5MP) |
Communication Interface | Supported |
Max Micro SD Card Supported | Up to 128G. Samsung’s U3 card is recommended |
(2.7K60/1080P120 requires U3 or above; other solutions require Ul orabove)
Please make sure that
the file format of the SD card is FAT32, othenA4, it will easily cause errors.
Mounting Hole Distance| 20.20mm / 25.5.25.5mm
PCB Size| 29’30mm
Lens Module Size| 19.19mm
Lens Specs| M12+0.5
Power Input| DC 5V
Working Current| 450mA@SV(Max)
Weight| 19.9g
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>