Intended use
The product is a deep well pump designed to be used with solar panels or a 24 V/DC system. Applications include livestock watering, irrigation, ponds, remote homes and cabins. Only for use with fresh water.
NOTE
- The product has an IPX8 ingress protection rating.
- The product is sealed and submersible.
- The product should be fully immersed in water and not be exposed to the sun.
- Please read the included safety instructions.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product for purposes other than those described above, the product may be damaged. In addition, improper use can result in short circuits, fires, or other hazards. Read the instructions carefully and store them in a safe place. Make this product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company names and product names are trademarks of their respective owners. All rights reserved.
Delivery contents
- Pump
- Power cable
- Operating instructions
Up-to-date operating instructions
Download the latest operating instructions at
www.conrad.com/downloads or scan the QR
code shown. Follow the instructions on the website.
Explanation of symbols
- **** The symbol with the exclamation mark in the triangle is used to indicate important information in these operating instructions. Always read this information carefully.
- This product is constructed according to protection class III.
- Not for use where flammable vapours are present.
- The arrow symbol indicates special information and advice on operation.
Safety instructions
**** Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.
a) General information
- The device is not a toy. Keep it out of the reach of children and pets.
- Do not leave packaging material lying around carelessly. This may become dangerous playing material for children.
- Protect the appliance from extreme temperatures, strong jolts, flammable gases, steam and solvents.
- Do not place the product under any mechanical stress.
- If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transportrelated stresses.
- Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.
- Consult an expert when in doubt about the operation, safety or connection of the appliance.
- Maintenance, modifications and repairs must only be completed by a technician or an authorised repair centre.
- If you have questions which remain unanswered by these operating instructions, contact our technical support service or other technical personnel.
b) Connected devices
- Also observe the safety and operating instructions of any other devices which are connected to the product.
c) Product
WARNING!
- Do not use the pump for petrol/gasonline, petroleum products, solvents, thinners or ANY other flammable liquid.
- Not for use where flammable vapours are present.
- Risk of damage. Do not operate the pump continuously.
- Observe a duty cycle of: ON: 45 mins / OFF: 15 mins.
Parts overview
|
Part
|
Material description
---|---|---
1| Clamp assembly| PA6; PBT + 40% GF; rubber; copper
2| Lift plate assembly| PA+ 30% GF; stainless steel 304
3| Pump head assembly| PPS + 40% GF; POM; PBT + 40% GF; rubber; copper
4| Valve seat assembly| POM; fluorine glue
5| Diaphram and rotating assembly| TPV; aluminum alloy; ferroalloy
6| Motor assembly| Aluminum alloy; copper; carbon steel
7| Sleeve| Stainless steel 304
Connection and installation
a) Cable
**** Do not use cables with irregularly shaped, rough, or grooved surfaces.
Recommended cable: ø1.63mm (14 AWG) jacketed submersible round cable.
b) Cable preparation
c) Wiring
-
STEP 1
-
STEP 2
-
STEP 3
Installation
a) Safety line (sling)
**** The safety line should be corrosion resistant
- Attach a safety line (parts not included) through the lift plate holes.
- Fix the line above the pump (30 – 60 cm) using an appropriate connection.
b) Connection
NOTE!
- Use cable ties every 1.8 m to bind the hose, safety line, and power cable. This will help prevent damage to the cable.
- The polarity does not affect the operation of the product (e.g. water flow direction and technical specifications are the same if the polarity is reversed).
Fuse
Maintenance and storage
- The product is maintenance free.
- Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can cause damage to the housing and malfunctioning.
- Regularly inspect electrical wiring and connections.
Disposal
This symbol must appear on any electrical and electronic equipment placed on the EU market. This symbol indicates that this device should not be disposed of as unsorted municipal waste at the end of its service life.
Owners of WEEE shall dispose of it separately from unsorted municipal waste. Spent batteries and accumulators, which are not enclosed by the WEEE, as well as lamps that can be removed from the WEEE in a non-destructive manner, must be removed by end users from the WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free takeback of waste. Conrad provides the following return options free of charge (more details on our website):
- in our Conrad offices
- at the Conrad collection points
- at the collection points of public waste management authorities or the collection points set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of. It should be noted that different obligations about the return or recycling of WEEE may apply in countries outside of Germany.
Technical data
- Input voltage / current: 24 V/DC, 6 A
- Power: max. 140 W
- Housing material: stainless steel
- Dry run protection: yes
- Duty cycle (intermittent): ON: 45 mins / OFF: 15 mins
- Fuse: 8 A
- Protection class: III
- Fluid medium: fresh water
- Well size: >10.16 cm (4”)
- Ingress protection: IPX8
- Discharge head: max. 70 m
- Immersion depth: max. 30 m
- Wire lead: 2 m
- Flow rate: …………………………………….max. 390 l/h
- Hose connection: ø12.7 mm (1/2”)
- Operating/Storage temp.: 0 to +40 ºC
- Dimensions (Ø x H): 98 x 310 mm
- Weight: 3700 g
Head flow table
Vertical lift
| Flow rate| Power| Current
---|---|---|---
Meters| Feet| Litres| Gallons| Watts|
Amps
6.1| 20| 390| 103| 43| 1.6
12.2| 40| 378| 100| 54| 2
18.3| 60| 366| 97| 62| 2.3
24.4| 80| 354| 94| 70| 2.6
30.5| 100| 342| 90| 80| 3
36.6| 120| 330| 87| 88| 3.3
42.7| 140| 318| 84| 96| 3.6
48.8| 160| 306| 81| 105| 3.9
54.9| 180| 294| 78| 113| 4.2
61.0| 200| 276| 73| 120| 4.5
70.1| 230| 252| 67| 135| 4.9
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com). All rights including
translation reserved. Reproduction by any method, e.g. photocopy,
microfilming, or the capture in electronic data processing systems require the
prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2022 by Conrad Electronic SE.
References
Read User Manual Online (PDF format)