ASTRALPOOL E Series E25 Saltwater Chlorinator Installation Guide

June 5, 2024
ASTRALPOOL

ASTRALPOOL E Series E25 Saltwater Chlorinator

WARNING


FOR YOUR SAFETY – This product must be installed and serviced by a trained Swimming Pool Technician in accordance with the latest applicable version of AS/NZS 3000, along with any other applicable local and national installation codes/standards”, and any other local applicable regulations. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death.

Section 1. Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a qualified installer and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

WARNING

The E Series Saltwater Chlorinator power supply has an IP23 rating, meaning it is suitable for installation outdoors. For safe operation the power supply must be installed in the correct orientation, with the cables leaving from the bottom of the device. If installing the power supply near the pool or spa water, you must ensure that the rules of AS3136 are followed at all times. AstralPool® strongly recommends that installation be performed by a registered pool builder, electrician or other suitably qualified person


WARNING

Risk of electric shock – Install the controller at least 3.5 metres from the inside wall of the pool and/or hot tub using non-metallic plumbing.

WARNING

If the supply cord is damaged, it must only be replaced by AstralPool, its service agent or a similarly qualified person, in order to avoid a hazard.
The transformer is not intended for series/parallel connection.
Never connect more than one light to a single power supply outlet. Each outlet on the power supply must go to one – and one only – underwater light.

SAVE THESE INSTRUCTIONS

Section 2. System Overview

Contents

Before starting, check that you have the correct parts as indicated in Table

  1. If any parts are missing or incorrect, please call your local distributor or technical support at 1300 186 875 for assistance.
Salt Chlorinator System

E25/E35 Saltwater Chlorinator


a. Controller
b. Wall Mount Bracket
c. Wall Mount Screws Ø7 mm (X2)
d. Wall Mount Anchor (X2) e. Electrolytic Cell
f. Unions (X2)
g. 50mm Glue on Adapter (X2)
h. O-ring (X2)

Table 1. Salt Chlorinator System Contents

Specifications

Salt Chlorinator System

| E 25| E 35
---|---|---
Nominal chlorine production| 25 g/h| 35 g/h
Nominal output amps| 4.4 A| 5.8 A
Required salt level| 6000ppm
Power supply voltage| 230 – 240 VAC
Protection index| IP23
Flow through the cell| Min. 80 Lpm
Operating water temperature| 10°C – 40°C

Table 2. Salt Chlorinator System Specifications

Dimensions

Controller

Cell

Materials and Tools

Controlle r

Tools Needed for Installation


  • Power Drill
  • 7 mm Drill Bit – Hammer Drill Bit (only necessary to drill into brick or concrete)
  • Pencil or Marking Pen
  • Pozidriv Screwdriver

Cell

Tools Needed for Installation


  • PVC Cutter
  • PVC Cement
  • Pencil or Marking Pen
  • Check Valve
  • 50 mm PVC Pipe (40mm optional)

Section 3. Plumbing

The cell must be plumbed in a position that is accessible for maintenance and within 1.5 meters of the controller. The cell should be the last piece of equipment in the circulation system. The cell must be installed horizontally, level and with correct flow orientation, see Figure 3.

  1. If you intend to plumb the cell on a bypass, the bypass must be equipped with Isolation valves, see Figure 3.
  2. Plumb the cell inlet and outlet on vertical lengths of 50 mm PVC pipe (if using 40mm pipe, use the provided 40mm reducers). The cell inlet and outlet ports are 11.5 cm apart, see Figure 2. The inlet of the cell is on the side closest to the electrical lead, see Figure 4.
  3. Put the lock nuts onto the inlet and outlet pipes in the correct orientation, see Figure 4.
  4. Glue the unions directly onto the pipes.
  5. Ensure the o-rings are seated properly on the unions.
  6. Secure the cell to the plumbing by tightening the unions hand tight. DO NOT OVERTIGHTEN.
  7. Double check cell orientation. The cell inlet is closest to the cell electrical lead.

WARNING


  • • The cell must be installed horizontally and level. Improper installation can lead to gas build up which could result in equipment damage or serious injury.
  • The cell must be the last piece of equipment on the return line, see Figure 3.
  • It is recommended in all installations that the cell is installed on a bypass equipped with isolation valves, see Figure 3.
  • In order to avoid load loss, installing the cell on a bypass is MANDATORY if system flow rated exceeds 300 Lpm, see Figure 3.
  • If installing on a bypass, use a downstream check valve instead of a manual valve to prevent improper back flow into the cell.

Section 4. Install Controller

The controller should be located at or near the equipment pad, at least 3.5 metres or more away from the inside wall of the pool/spa, 1.5 metres off the ground, and within 1.5 meters of the cell. All national, state, and local codes are applicable.

Mount the Bracket
  1. Determine the controller location.
  2. Use the enclosed bracket to mark the mounting surface through the screw holes.
  3. Drill surface with 7 mm bit.
  4. Install the included wall anchors.
  5. Hang bracket using the included screws.
  6. Hang the controller on the wall bracket and slide down to secure in place.
Electrical Connections

WARNING

FOR YOUR SAFETY: This product must be serviced by a professional pool/spa service technician as described on the front cover of this manual. The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death. Improper installation and/or operation will void the warranty.


The controller must be permanently powered by connection to a 30 mA residential circuit breaker.
A non-replaceable backup power source is incorporated to maintain time-setting memory in the event of a short, infrequent power interruption.

Controller and Chlorinator Cell Wiring

  1. Connect the Chlorinator Cell Cable to the appropriate ports on the cell.
  2. Connect the E25/E35 Controller to the power source.

Section 5. Prepare and Balance the Pool

Water Chemistry Table

Test and maintain correct water balance throughout the season, according to the table.

| Free Chlorine| pH| Total Alkalinity (ppm)| Calcium Hard- ness (ppm)| Cyanuric Acid (ppm)| Salt Level (ppm)| Met al
---|---|---|---|---|---|---|---
Australian Standard| 1 -3| 7.2 – 7.8| 60 – 200| 100 – 400 | up to 50| 4000 – 7000| x
Ideal range| 1 – 3| 7.4| 80 – 140| 90 – 300| up to 50| 4000 at 27°C| < 0.10 ppm
To Increase| Add chlorine or increase equip- ment output| Add buffer or soda ash (so- dium carbonate)| Add sodium bicarbonate| Add calcium chloride| Add cyanuric acid| Add salt or minerals
| x
To Decrease| | Add muriatic acid| Add muriatic acid or dry acid| Partially drain and refill pool
| Partially drain and refill pool| Partially drain and refill pool| Use ‘Metal Remover’
In Season Testing Frequency| Weekly| Weekly| Weekly| Weekly| Weekly| Monthly| Monthly

NOTE: Test all equipment sensors quarterly.

  • Fill pool with water from the mains water supply. Do not use rain water or well water.
    ** Do not add salt directly into the skimmer. Do not initiate electrolysis until salt has fully dissolved.
    *** Reading is True Calcium Hardness, not Total Hardness.
    Table 3.Water Chemistry

Section 6. Operation

User Interface Overview

Initial start-Up

CAUTION

To avoid risk of serious damage to the equipment, ensure that all salt added to the pool has completely dissolved before activating the chlorination function of your system.


The following setting must be configured at the initial start up of the device. Settings can be changed or updated at a later time using the general menu, details can be found in Section 7.

Output can be set between levels 1 to 8 (P1 to P8), this is controlled in increments from the “main screen” by pressing UP or DOWN . The set value is valid until the next modification.

System Power

  1. Press AUTO to cycle between:
    Manual – Running
    Manual – Stopped
    Auto

Auto – Running indicates that the chlorinator is running within a timer period.
Auto – Stopped indicates that the chlorinator is outside of a timer period.

Set Clock

  1. Press MENU and screen should display CLK. Press ENTER .
  2. Press ENTER and the hour digit will flash. Use UP or DOWN  to adjust.
  3. Press ENTER to change to minutes and set. Use UP  or DOWN  to adjust.
  4. Press ENTER and select AM or PM. Use UP or DOWN to adjust.
  5. Press MENU to save.

Section 7. Installing Equipment

Programming/Timers

The controller has an internal operating timer that is used to define the length of time for the filter pump to operate during two separate time periods each day.
In order to complete the timer program, it is necessary to enter and validate both ON and OFF times. If no timer is set, the filtration and / or chlorination will run continuously
The filtration operating times must be sufficient to correctly treat the water.

Example – single speed pump:
In Season filtration time: 8-10 hours per day.
Off Season filtration time: 4-5 hours per day.
Example – variable speed pump (when running at lower speeds):
In Season filtration time: 12-14 hours per day
Off Season filtration time: 8-10 hours per day

Filter Pump Programming

  1. Press MENU
  2. Press the MENU again and screen should display TMR. Press ENTER .
  3. Use UP or DOWN  ****to adjust start time for TIMER 1. Press ENTER .
  4. Use U P or DOWN to adjust the stop time for TIMER 1. Press ENTER .
  5. Repeat for TIMER 2.

User Operation Modes

The user mode buttons enable you to select and to automatically or manually control the chlorinator/ pump. Functions are as follows:

a. POOL MODE:

  • Auto – Running/Stopped: The chlorinator/pump will run according to how you have set the timers.
  • Manual – Running: The chlorinator/pump will run continuously.
  • Manual – Stopped: The chlorinator/pump will stay off continuously.

Maximum efficiency will be achieved from your chlorinator at the following levels:

  • Water temperature 15 Degrees ­ Salt level required is 6000 ppm.
  • Water Temperature 25 Degrees ­ Salt level required is 4,100 ppm.

Section 8. Inspecting and Cleaning the Electrode

In areas that experience calcium hardness the cell electrode will benefit from cleaning.

  1. Switch off the filter pump and chlorine generator, close necessary valves and unplug the cell terminal cap.

  2. Unscrew the retaining ring and remove the electrode. If calcium buildup is present, immerse the electrode in cell cleaning solution without immersing the terminals.

  3. We recommend using Purex Salt Cell Cleaner to clean the electrode. However, you can mix your own by carefully adding one (1) part of Hydrochloric (Muriatic) acid to ten (10) parts water. Stronger solutions will shorten terminal life.

  4. Allow the cleaning solution to dissolve the calcium deposits for about 10 minutes.
    NOTE: Dispose of the cleaning solution at an approved Council Depot and never into storm water or sewage drains.

  5. Rinse the electrode in clean water and re-fit the electrode in the cell housing.

  6. Replace the cell head and plug assembly.

  7. Reset valves and switches.

  8. Turn pump and controller on.

  9. Confirm chlorine output and settings on the power pack. Timer programs will be automatically retained.

Section 9. Winterizing

The chlorinator has a protective system which will limit sanitizer production during unfavorable operating conditions, such as cold water or lack of salt.

Active winterizing leaves the filter pump and chlorinator running during the winter. This is safe for temperatures above 10°C. If temperatures drop below 10°C, the chlorination cell needs to be deactivated.

Passive winterization calls for the pool to be shut down. Water levels will need to be lowered and the piping will need to be drained. The cell electrode can be left in place with isolation valves open.

Reopening the Pool

Required actions:

  1. Adjust the water level (too much or too little)
  2. Check the water parameters.
  3. TAC/TH/pH/Salinity/Chlorine/Stabilizing Agent/ Copper/Metals.
  4. Adjust the parameters to obtain a balanced, healthy pool, see Section 5.
  5. Check the condition of the equipment (pump, filter, chlorinator, electrolytic cell).
  6. Where necessary, check the sensors, clean if needed and re-calibrate.
  7. Once the salt level has reached the required level of 6000ppm and has dissolved in the water, restart the salt chlorinator.

Section 10. General Maintenance

If the supply cord is damaged, it must be replaced by AstralPool, its service agent or a similarly qualified person in order to avoid a hazard.

⚠ WARNING

Operating the chlorinator with less than 3000 ppm of dissolved salt in the water may cause damage to the cell and will void the warranty.

Never start the chlorinator, until the correct quantity of salt has been added and dissolved in your pool water.


Cell Maintenance

Your E25/E35 Saltwater Chlorinator has an automatic cleaning feature, that under normal conditions, will keep the cell plates clear of deposits of salt and calcium.

The cell has a negative charge sensor that monitors the flow and salt levels of the water. This sensor is designed to be fail safe. As it is negative charge deposits of calcium or other debris that may be deposited on it, causing an indication of low salt or no flow condition.

Should a low salt condition be indicated, have your salt level checked at your local pool shop. If the low salt condition persists, or a no flow condition is indicated when the supply pump is operating, you may need to manually clean your E25/E35 Saltwater Chlorinator Cell. See Section 9 for cleaning instructions.

Maintenance Schedule

The E25/E35 Saltwater Chlorinator has high velocity water with chemicals in it. Some of these parts will wear in the normal course of use and require regular checks and maintenance. Performing these checks and maintenance will identify parts that have worn and require repair/ replacement before further serious damage is sustained. A small amount of regular care and attention to your pool equipment will help ensure long life and trouble free performance.

To protect against extremes of temperature, your unit is vented to allow the electronics to cool. Ants and some insects are often attracted to the warmer, dry environment inside the enclosure. We recommend that, with power turned off, you spray a surface insecticide on the surfaces surrounding the control to prevent ant and insect ingress. Repeat every three months or as necessary.

Note: Regular maintenance is important to ensure long life and trouble free performance of your pool equipment. If unable to perform the maintenance yourself, contact your local pool professional to request assistance with the maintenance.

Timing Maintenance Check Service Action If Required
Weekly or sooner Check Cell for calcium buildup Soak electrode in mixture of

10 parts water to 1 part acid. Use a soft brush only if required.
Check water chemistry| Balance pH in pool and adjust output of unit to ensure satisfactory production of chlorine.
Check cable connections to Cell| Ensure no water contact is occurring with pins.
Every Three Months| Check Cell connections for leaks| Isolate Pump, turn power off, clean and grease O rings or replace if necessary
Check for insects/ants| Spray a surface insecticide on the surfaces around the unit to prevent ant and insect ingress
Every Six Months| Check chlorine levels and pump operating hours| Adjust timer and output depending on demand for current season.
Prevent insect ingress to controller| Turn controller off, use an insect spray and spray onto walls around controller. Do not spay directly into unit.

Table 4. E25/E35 Saltwater Chlorinator Maintenance Schedule

Section 11. Troubleshooting

When there is an error condition, “ERROR” flashes on the display along with the error code.

Fault Indication Possible Cause Solution
NO FLOW (NO F)
  • Pump turned off/disconnected or valves closed
  • Blue wire disconnected from cell

|

  • Ensure valves/pump ON
  • Connect BLUE sense wire to cell

LOW SALT (LO S)|

  • Salt level in pool has dropped too low
  • Pool water temperature is low
  • Cell has calcified
  • Cell has failed

|

  • Take sample of water to retailer and check salt level – add salt as recommended.
  • Add salt and turn chlorinator output down until the water is warmer.
  • Clean the cell
  • Call for service

Display Blank|

  • No power to controller
  • Fuse blown

|

  • Plug in controller and ensure main power available
  • Have a service technician replace fuse (2A slow blow)

Low/No Chlorine in pool|

  • Cables not connected to cell
  • Timer period too short
  • Chlorine output level too low
  • Filter needs backwashing
  • pH too high
  • Pool stabiliser (cyanuric acid) too low
  • Salt level too low

|

  • Connect cables
  • Increase timer period (particularly during summer)Increase chlorine output
  • Backwash filter
  • Balance pH level to 7.4 – 7.6
  • Increase stabiliser between 30 – 60 ppm.
  • Increase salt to above 6000 ppm

Clock loses time when main power is removed|

  • Clock power backup failed

|

  • Call a technician

Timer is set to OFF in the TMR menu|

  • The timer has been turned off

|

  • Use AUTO to turn the timer back on. Adjust timer start and stop times to suit.

Table 5. Troubleshooting

| For full warranty terms and conditions and to register your warranty, simply visit www.astralpool.com.au/warranty or www.astralpool.com.nz/warranty and complete your details. Or scan the QR code and be taken directly to the registration page
---|---
| Record your equipment details here for quick reference:
Model No.: ____
Serial No.: ____

Fluidra Group Australia
219 Woodpark Road
Smithfield, N.S.W., 2164, Australia
1.300.186.875
www.astralpool.com.au

©2021 Fluidra S.A. All rights reserved. This document is subject to change without notice.

Documents / Resources

| ASTRALPOOL E Series E25 Saltwater Chlorinator [pdf] Installation Guide
E Series, E25, E35, Saltwater Chlorinator
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals