HYUNDAI DHY8600SE Electric Generator User Manual

June 5, 2024
HYUNDAI

HYUNDAI logo

User manual

HYUNDAI DHY8600SE Electric Generator
DHY8600SE

SAFETY

| Perform a visual inspection of the external and internal components.
---|---
| The temperature range for the use of this equipment is between + S•C and + 40°C
| All items must be cleaned regularly.
| The air filter must be cleaned regularly.
| SAFETY / SIKKERHET
The exhaust gases contain carbon monoxide. This gas is colorless and colorless and is very dangerous. NEVER USE THE EQUIPMENT IN A LOCATION CLOSED OR WITH POOR VENTILATION.
| The repair of the generator must be carried out by qualified and authorized personnel for this purpose
| Store the generator in an area with good ventilation
| SAFETY / SIKKERHET
The guarantee is automatically canceled if you do not follow the described start and stop the process.
| Failure to follow the described process may damage the equipment. For this purpose
| Check the screws and nuts that due to the vibration of the equipment could loosen.
| SAFETY / SIKKERHET
Good quality oil and fuel are imperatives for using the equipment.
| Long-term storage should be done in a dry place. Frost can damage the equipment.
Thoroughly dry equipment before storage and store in a dry, not cold place.
| Make sure all filters are cleaned regularly.

SAFETY /SIKKERHET

The exhaust temperature is high during use of the equipment and remains warm even after the generator is turned off. Be careful not to touch the hot exhaust and wait for the equipment to cool down before moving it.
Do not smoke and avoid flames and sparks when using the generator or when filling the tank. Do not store the generator near flammable material to avoid explosion hazards.
Never place the generator in an inclined or vertical position, to avoid fuel loss and equipment damage.
ALWAYS control the oil and fuel level, as well as its maintenance before each use

CONTROLS PANELS

1 LED6 display
2 Start key
3 Emergency stop
4 Breaker
5 AUTO socket
6 ATS socket
7 Earth terminal
8 Pre-heater button
9 Overload protector
10 230V 16A Socket 230V 16A
11 230V 32A Socket 230V 32A

Starting-up the machine

Check the oil level whenever the appliance is to be put into operation. Add engine oil if necessary.
To ensure quality, every piece of equipment is subject to a test operation and filled with motor oil. Oil is drained before transport; however, there can be some motor oil remains on the dipstick. Please check carefully the oil level and add motor oil again

Filter position

Oil fillingHYUNDAI DHY8600SE Electric Generator - Fig
3

Connect battery cable

HYUNDAI DHY8600SE Electric Generator - Icon 16HYUNDAI DHY8600SE Electric Generator - Fig
7

Fuel tank filling
HYUNDAI DHY8600SE Electric Generator - Fig 8 Exhaust the air from the fuel pipe
HYUNDAI DHY8600SE Electric Generator - Fig 9 OPERATl ON – STARTHYUNDAI DHY8600SE Electric Generator -
Fig 10

OPERATION – AUTOSTART

HYUNDAI DHY8600SE Electric Generator - Fig 12 Operation – STOP![HYUNDAI DHY8600SE Electric Generator

Oil change
HYUNDAI DHY8600SE Electric Generator - Fig 15
Oil filter clean
HYUNDAI DHY8600SE Electric Generator - Fig 17

Air filterHYUNDAI DHY8600SE Electric Generator - Fig
18

Fuel filterHYUNDAI DHY8600SE Electric Generator - Fig
20

Model DI-IY86005E DHY86005E-T
Frequency Hz 50
Rated Power 6.0 kw
Max. Power 6.3 kw
Voltage V 230
Current A 27.
Plugs 16A & 32A
Display LED6
Fuel tank capacity L 13
Running time a 75% load H 7
Sound level a 7m dBA 72
DC output V/A 12 / 8.3
Battery V/Ah 12 / 36
ENGINE D500E D500E
Engine type Diesel
Power hp 12
Start Electric
Displacement CC 498
Oil Capacity L 2.
ALTERNATOR AL6 AL6-T
Power Kw 6
Power Factor 1
Voltage Regulation Brush / AVR
DIMENSIONS & WEIGHT
Net Weight Kg 154
Gross Weight Kg 162
machine size mm 920 x 520x 720
Dimensions Package mm 960 x 560x 760

Feilsøking, motoren starter ikke

Causes|
---|---
Fuel shortage| Fill with fuel
Air in the circuit| Purge the air in the circuit
The start lever is not in the run position| Pul the lever in the run position
Check the oil level| Fill oil to the upper mark
injector dirt| Clean the injector
Battery without charge| Charge the battery
The injector does not supply fuel| Repair or replace the injector

The generator does not give current

**** Causes Solutions
The differential is in the off position Put the differential in the ON
Bad contact at the plug Adjust the plug
AVR Damaged voltage regulator (AVR) Replace Voltage Regulator (AVR)

Lav spinning

Causes Solutions
Bad contact at the plug Adjust the plug
AVR Damaged voltage regulator (AVR) Replace Voltage Regulator (AVR)

Manufacturer
KAT POWER INTERNATIONAL, S.L.
Hereby certifies thai the following
Generator
DHY8600SE
Is in compliance with the specifications of the machine directive and subsequent modifications
2006/42/EC (MD) DirectivaDirective
2014/30/EU (EMC) Directive
2000/14/EC (amended 2005/88/EC)
96 Lwa dBA 2016/1628 Directiva
Emisiones EUROS e92016/16282016/1628EC1/D121000 engines 418 and 496cc
Conforms with the following standards
EN ISO 8528-13:2016
EN ISO 60204-1:2006/AC:2010
AN ISO 5395-2: 2013
EN 55012:2007+A1:2009 and EN 61000-6-1 :2007 (EMC)
EAN ISO 3744:2010, ISO8528-10:1998 (sound level)

Kat Power International, S.L.
Avda. Algoma, BA
17771 Sta. Llogaia Alguema, Spain

Licensed by HYUNDAI Corporation, Korea