FS M6800 Series OTN Platform User Guide
- June 5, 2024
- FS
Table of Contents
FS M6800 Series OTN Platform User Guide
Introduction
M6800-TSP16 is an OTN transmission platform customized for Data Center Interconnect (DCI) applications. It’s up to eight single wavelength 200G channels, with 8x 200G CFP2 coherent optics uplinks on the line side, and 16x 100G QSFP28 on the client side.
Accessories
- Power Cord x2
- Console Cable x1
- Ethernet Cable x1
- CD x1
- Cable Manager x1
- Mounting Bracket x2
- ESD Wrist Strap x1
- Grounding Cable x1
- M6 Screw Set x4
- M4 Screw x8
Hardware Overview
Front Panel Ports
Port | Port Type | Description |
---|---|---|
Clinet Port | QSFP28 | Support 16x 100G QSFP28 |
Line Port | CFP2 | Support 8x coherent 200G CFP2 |
MGMT1~2 | RJ45 ETH | Connect to the local network management computer |
CONSOLE | Micro USB | Debugging & Upgrading port |
Front Panel LED
LED | Status | Description |
---|---|---|
SYS | Slow Flash of Green Light | The system works normally. |
Always OFF | The system is not normally enabled. |
ALM
| Quick Flash of Red Light| There is a critica alarm of the device.
Slow Flash of Red Light| There is a major alarm of the device.
Always Red| There is a minor alarm of the device.
Always OFF| There is no alarm of the device.
Back Panels
LED | Status | Description |
---|
Port Indicator
| Always OFF| The port is disabled.
Quick Flash of Red Light| There is a mismatch alarm of the port.
Always Red| There is a los alarm of the port.
Always Green| There is no los and mismatch alarm of the port.
Back Panel LED
LED | Status | Description |
---|---|---|
FAN | Always Green | There is no alarm of those fans. |
Always Red | There is alarm of those fans. |
Site Environment
Keep the equipments indoors. If it is in rainy season or in humid environment,
dehumidification measures must be taken.
Ensure there is no water on the storage fioor and no leakage to the packing
box of the equipment. Avoid automatic fire fighting facilities, heating system
and other places where leakage may occur.
- Installing
Installing Mounting Brackets
- Secure the mounting brackets to the two sides of the 200G transponder with 8x M4 screws.
- Put the 200G transponder on the shelf in the cabinet.
- Install and tighten the panel with 4 sets of M6 screws.
- Cable manager can be installed together with mounting brackets to the cabinet.
Wearing ESD Wrist Strap
- Before touching any device or module, wear an ESD wrist strap or ESD gloves to protect sensitive components against electrostatic discharge from the human body.
- Connect other end of the ESD wrist strap to the PGND point on the device.
Grounding the 200G Transponder
- Secure the grounding lug to the grounding point on the chassis front panel with the washers and screws.
- Connect the other end of the cable to a proper earth ground, such as the rack in which 200G transponder is mounted.
Connecting Power Cord
- Plug AC power cord into the power port on the front panel of AC power module.
- Connect the other end of the power cord to an AC power source.
WARNING: Do not install power cables while the power is on.
Connecting QSFP28 Transceiver
- Plug the QSFP28 transceiver into the QSFP28 slot on transponder.
- Connect one end of fiber cable to the QSFP28 transceiver.
- Connect the other end of fiber cable to switch.
Connecting Coherent CFP2 Transceiver
- Plug the CFP2 transceiver into the CFP2 slot on transponder.
- Connect one end of fiber cable to the CFP2 transceiver.
- . Connect the other end of fiber cable to mux demux or optical amplier module.
Connecting to the Management Ports
- Connect one end of the standard RJ45 Ethernet cable to the MGMT1&2 port on the 200G transponder.
- Connect the other end of cable to a computer.
Configuring the M Series Platform
Configuring the M Series Platform Using the Web-based Interface
- Step 1: Connect your computer with the network cable to any Ethernet MGMT port of the NMU module.
- Step 2: Get the NMS software from the CD of chassis accessories or deownload the file “NMS software”
- Step 3: Double Click “NMS Server” icon on the desktop and the dialogue box of license validation will pop up.Enter the license key(included in the CD) to finish validation. (If you can’t find the license key,please contact FS asles manager for help.)
- Step 4: Then the NMS server interface pops up. Double click “Start NMS Server” to run the server, when it prompts “Please connect your client to the web server on port: 9090”, it means that you have successfully started the NMS server. And then you can close the NMS Server window, the server is still running in the background.
- Step 5: Open a browser window. (Recommend IE11.0 and above version or Google Chrome browser).
- If you log in from local NMS host, enter localhost:9090 in the address bar to open the login interface.
- If you log in from other remote host, enter the server IP address XXX.XXX.XXX.XXX:9090 (IP address of NMS server) to open the login interface.
- Step 6: Enter correct user name and password (For the administrator, the default login user name is “root”, and the default password is “public”), as shown in the figure below:
- Step 7: Click login, you are now ready to configure M series platform.
NOTE: Refer to the M SERIES NETWORK MANAGEMENT USER MANUAL online for further information.
Troubleshooting
Module LEDs Working Abnormally
- Check the power cable connections at the 200G transponder and the power source.
- Make sure that all cables are used correctly and comply with the power specifications.
Accessing the Wed-based Configuration Page Unsuccessfully
- Check MGMT ports LED on the 200G transponder and make sure the Ethernet cable is connected properly.
- Try another port on the 200G transponder and make sure the Ethernet cable is suitable and works normally.
- Power off the 200G transponder.After a while, power it on again.
- Make sure the IP address of your NMS server is correctly configured.
- If you still cannot access the configuration page, please reinitialize NMS server to its factory defaults.
Business Module Cannot Be Added
- Enter through CMD.
- Ping business module IP to check whether it can communicate.
- Check whether normal communication can be made between business module and NMU module.
- Change another business module.
Online Resources
Download https://www.fs.com/download.html
Help Center https://www.fs.com/service/help_center.html Contact Us
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our
workmanship, we will offer a free return within 30 Days from the day you
receive your goods. This excludes any custom made items or tailored solutions.
Warranty: M6800 series enjoy 2 years limited warranty against defect in
materials or workmanship. For more details about warranty, please check at :
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be
found at: https://www.fs.com/policies/day_return_policy.html
References
- FS.com - HPC, Data Center, Enterprise, Telecom
- HPC, Data Centre, Enterprise, Telecom - FS.com United Kingdom
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- FS.com - Data Center, Enterprise, Telecom
- Contact Us - FS.com
- Kontakt - FS.com Deutschland
- Technische Dokumente - FS.com Deutschland
- Rückgaberecht - FS.com Deutschland
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- Hilfezentrum - FS.com Deutschland
- Technical Documents - FS.com
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Comment Nous Contacter - FS.com France
- Documents techniques - FS.com France
- Politique de retour - FS.com France
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Centre d'aide - FS.com France
- Return Policy - FS.com
- Products Warranty - FS.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>