BEFORE YOU START

Turn off Power at Breaker

Input Voltage: 100–277 VAC, 1 Φ, 50/60 Hz Do not connect the fan to a damaged power source. Do not attempt to resolve electrical failures on your own. Contact a licensed electrician if you are uncomfortable performing electrical work. A licensed electrician must install the fan if required by local code.
Input Voltage

  • Do not use the fan with a dimmer switch.
  • WARNING: Installation must be in accordance with the requirements set forth by the National Electrical Code (NEC, United States), ANSI/NFPA 70, and all national and local codes.
  • The ground wire must be connected to the supply ground and its length must be longer than the safety cable.
  • A means for disconnection must be incorporated in the fixed wiring in  accordance with the wiring rules.

Gather Tools
Gather Tools

Prepare Fan Site

Outlet Box: Make sure your outlet box is suitable for fan support. If there is not an outlet box at the fan location, install one on a ceiling joist or beam.

Concrete Ceiling: Install an anchor hook for the safety cable if required by your local building and safety code. See the following page for installation details.

Wood Ceiling Joist: Attach the mounting bracket directly to the joist using two wood screws (not supplied). Recommended: Corrosion-resistant 12-11 x 45 mm hex head timber screws with seal. If required by local code, mount or embed an outlet box into the joist. The outlet box must be suitable for fan support.

The mounting/fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand four times the weight of the ceiling fan.

Models and Maximum Weight:
MK-ES62-052306: 25 lb (11.3 kg), MK-ES62-062306: 27 lb (12.1 kg),
MK-ES62-072306: 29 lb (13.2 kg)

Prepare Concrete Ceiling (if applicable)

Drill three Ø 8 mm holes in the pattern shown. The hole depth should not exceed 46 mm. Remove any dust from the holes. Insert three anchor bolts into the holes. Strike the heads of the anchor bolts with a hammer, ensuring the bolt sleeves are flush with the ceiling surface. Position the mounting bracket on the anchor bolts. Ensure all three anchor bolts are fully tightened to expand and lock the anchors.

If required by local building and safety codes, install an anchor hook for the safety cable. Drill an Ø 8 mm hole for the anchor hook. The hole depth should not exceed 46 mm. Remove any dust from the hole, and then insert the anchor hook and fully tighten.
Prepare Concrete

PARTS AND HARDWARE

PARTS AND HARDWARE

INSTALLATION

Install downrod

Align holes on downrod with holes on motor bracket. Secure downrod with the M6 x 32 mm bolt and M6 nut (Fig. 1.1). If you are installing the optional uplight, make sure the downrod wiring harness and the motor unit wiring harness are on opposite sides of the downrod. This will make the harnesses easier to connect to the uplight.
Install downrod

If you are NOT installing the uplight, connect downrod wiring harness to motor unit wiring harness (Fig. 1.2). If you are installing the uplight, do not connect the downrod wiring harness.
Install downrod

Install lower safety cable and ground wire

Install safety cable and ground wire lugs with unpainted screws and lock washers (Fig. 2.1).
Install lower safety cable and ground wire

Install uplight (optional)

Skip this step if you are not installing the uplight.
Make sure wiring harnesses are as close to downrod as possible so that they do not interfere with uplight installation (Fig. 3.1).
Install uplight \(optional\)

Skip this step if you are not installing the uplight.
Align rectangular cutouts in center of uplight with bolts on downrod. Make sure uplight wiring harness and motor unit wiring harness are on opposite sides of downrod. This will make the harnesses easier to connect. Slide uplight down the downrod, resting it on the fan hub (Fig. 3.2).
Install uplight \(optional\) \(cont.\)

WARNING: Skin or eye damage may result from directly viewing ultraviolet light produced by the lamp in this apparatus. Always disconnect power before relamping or servicing. Replace ultraviolet LEDs with Model No. 1050-45-50, manufactured by Big Ass Fans.

Skip this step if you are not installing the uplight.
Tighten the two set screws at top of uplight. Connect uplight wiring harness to motor unit wiring harness. Connect downrod wiring harness to receptacle on uplight (Fig. 3.3).
Install uplight \(optional\)

Reduce slack

Make sure all hardware is secure, and then gently tug cables at top of downrod to reduce slack (Fig. 4).Reduce slack

Position wiring cover and canopy

Slide wiring cover down downrod, resting it on the fan hub or uplight. Make sure no wires are visible between the cover and fan hub or uplight. Slide canopy down downrod, resting it on the wiring cover (Fig. 5).
Position wiring cover and canopy

Install mounting ball

Slide mounting ball over downrod (Fig. 6.1).

Insert 6 mm steel pin into hole at top of downrod, and then slide the mounting ball upward, seating the steel pin in the inner slots (Fig. 6.2).

Insert wedge into mounting ball and secure with screw. Tighten screw enough to prevent movement between the mounting ball and downrod, but do not over tighten (Fig. 6.3).
Install mounting ball

Install mounting bracket

Disconnect power to fan location before installing mounting bracket.
WARNING: Mount only to an outlet box marked acceptable for fan support.

Secure mounting bracket to mounting structure with suitable hardware (not supplied) (Fig. 7). Outlet box shown. Your mounting structure may diff er from the illustration. Power supply omitted from mounting bracket illustration for clarity.
Install mounting bracket

Hang fan

Raise fan to mounting bracket. Align rib in mounting bracket with slot in mounting ball, position mounting ball, and let fan hang freely (Fig. 8).

Gently twist downrod to ensure it is properly seated and will not move during fan operation.
Hang fan

Wire fan

Disconnect power to fan location before wiring fan.

Wire fan as shown using the wire connectors (Fig. 9). Attach green ground wire to mounting bracket with the unpainted screw. Connect wiring harness from power supply to wiring harness from downrod, making sure that the wiring and safety cable are routed in the same direction.

Carefully tuck wiring into outlet box or building structure. Ensure wire connectors are turned upward and that wires are spread apart with grounded conductors on one side of the outlet box/mounting structure and ungrounded conductors on the other side.
Wire fan

Supply Power Wire Color Chart

  North America 100–120 V Australia All other regions
AC Hot/L1 Brown Black Brown or Red Brown
AC Neutral/L2 Blue White Black or Light Blue Blue
PE/Earth Ground Green with Yellow Green or Bare Copper
Green with Yellow Green with Yellow

Install fan stabilizer (optional, outdoor fans only)

The fan stabilizer is included only if purchased as an outdoor fan accessory.

If you purchased the fan stabilizer kit, fit stabilizer into notches on top of mounting ball (Fig. 10.1).
Install fan stabilizer \(optional, outdoor fans only\)

Secure stabilizer plate to stabilizer with the M6 x 70 mm bolt and M6 nut (Fig. 10.2).
Install fan stabilizer \(optional, outdoor fans only\)

Secure safety cable

Some local safety codes require the safety cable to be secured directly to an existing part of the building structure (Canada, Singapore). It may be necessary to install additional structural material to provide attachment points. Check your local safety code if you are unsure. Contact Customer Service for help.

Mounting Bracket
Loop safety cable around mounting bracket, and then secure it with the shackle (Fig. 11.1).
Secure safety cable

Anchor Hook
Loop safety cable around anchor hook, and then secure it with the shackle (Fig. 11.2).
Secure safety cable

Building Structure
Loop safety cable around building structure, and then secure it with the shackle (Fig. 11.3). Acceptable building structures include a wooden beam or a metal mounting brace secured between two beams. In some cases it may be necessary to install additional structural material to provide attachment points.
Secure safety cable

Raise canopy

Raise canopy to mounting bracket, aligning the four holes on the canopy with the holes on the bracket. Secure canopy to mounting bracket with the painted screws (Fig. 12).
Make sure all wires and the safety cable are tucked in the canopy
Raise canopy

Install airfoils

Tilt airfoil so that tip is angled upward as shown. Slide airfoil into slot on side of motor unit, and then tilt downward into place. Install each airfoil on opposite side of fan from previous airfoil to prevent fan from tilting (Fig. 13.1). Make sure numbered sticker on each airfoil matches corresponding slot number on bottom of fan. Ensure all airfoils are fully seated in slots before tightening screws on bottom of fan.
Install airfoils

Tighten the six airfoil screws on bottom of fan according to numbered sequence (Fig. 13.2). When finished, repeat tightening sequence. Verify all six screws are fully tightened by making sure the tabs next to holes 1 and 5 are flush with the openings.
Install airfoils

Install lower cover

Align slots on lower cover with tabs on bottom of fan and twist cover clockwise to lock (Fig. 14.1).
Install lower cover

Install LED light (optional)

CAUTION: To reduce the risk of electric shock, disconnect power to fan before installing LED light.

Plug LED light wiring harness into receptacle on bottom of fan. Align slots on light with tabs on bottom of fan and twist light clockwise to lock (Fig. 14.2).
Install LED light \(optional\)
Use only with light kits marked “Suitable for Use in Wet Locations.”
Use only light kit model 009786. Light Kit Weight: 2.2 lb (998 g)

Congratulations!

Installation is now complete. Turn on power and test your fan using the remote control.

ADJUSTMENT

Press Auto to enable motion sensing and automatic fan speed adjustment as room conditions change. To adjust your Auto preferences, download the Big Ass Fans mobile app.

Press and hold to change control modes:

  • Uplight only
  • LED light only
  • Both lights simultaneously

To change the color of the uplight’s LEDs, download the Big Ass Fans mobile app.

For operation, maintenance, and troubleshooting information, visit bigassfans.com/support
QR Code

Removing the lower cover or LED light

If you need to remove the lower cover, twist cover counterclockwise and slide down (Fig. 15.1).
Removing the lower cover

If you need to remove the LED light, use a long, thin object such as a small allen wrench or pen tip to press tab on light. While pressing tab, twist light counterclockwise and slide down (Fig. 15.2).
Removing the lower cover

MAINTENANCE AND CLEANING

WARNING: Risk of fire, electric shock, or injury to persons during cleaning and user maintenance. Disconnect the appliance from the power supply before servicing.

WARNING: Skin or eye damage may result from directly viewing ultraviolet light produced by the lamp in this apparatus. Always disconnect power before relamping or servicing.

Please take a few moments each year to perform the following preventative maintenance procedures on your fan to ensure its safe and efficient operation.

Checking the safety cable

Check that the safety cable is properly installed by removing the canopy screws, sliding the canopy down the downrod, and examining the safety cable and hardware.

Checking the hardware

Make sure the mounting hardware and the screws securing the airfoils to the fan hub are securely fastened. Tighten the six airfoil screws on the bottom of the fan according to the numbered sequence. When finished, repeat the tightening sequence.

Checking the wiring

Make sure the wire connectors are secure and the ground wires are securely connected.

Cleaning the airfoils

Dust the airfoils regularly. If the fan becomes dirty, clean it with a damp clothand ordinary soap and water. Do not use solvents, gasoline, or any other chemical cleaners! These may cause surface distortion and damage to the fan.

Cleaning the uplight

Clean the LEDs periodically to ensure optimal performance. Use a compressed air duster to remove dust and debris from the LEDs. Do not touch the LEDs while cleaning. Hold the duster can upright when using.

CONTACT US

United States
2348 Innovation Drive
Lexington, KY 40511
USA
877-244-3267
Outside the U.S. (+1 859-233-1271)
bigassfans.com

Australia
35 French Street
Eagle Farm, Brisbane
QLD 4009
Australia
+61 1300 244 277
bigassfans.com/au

Malaysia
BAFCO Asia Sdn Bhd (965032-V)
No 4, Jalan Jururancang U1/21A
Hicom Glenmarie Industrial Park
40150 Shah Alam, Selangor,
Malaysia
(+603) 5565 0888

Manufacturer
2348 Innovation Drive
Lexington, KY 40511
USA

Manufacturing Site
2251 Innovation Drive
Lexington, KY 40511
USA

Canada
2180 Winston Park Drive
Oakville, Ontario L6H 5W1
Canada
1 844-924-4277
bigassfans.com/ca

Singapore
18 Tampines Industrial Crescent #06-07
Singapore 528 605
+65 6709 8500
bigassfans.com/sg

Mexico
CEBSA (Corporación Eléctrica del Bravo
SA de CV)
Avenida Ind. Rio San Juan
Lote 3-A Parque Industrial del Norte
Reynosa, Tamps C.P. 88736
+52 1 899 925 6398
http://cebsainc.com/

All Other Geographies
+1 859-410-6286
bigassfans.com

Warranty and WEEE Returns
2201 Jaggie Fox Way
Lexington, KY 40511
USA

The information contained in this document is subject to change without notice. For the most up-to-date information, see the online printable installation guide at www.bigassfans.com/support
www.bigassfans.com/patents
www.bigassfans.com/product-warranties

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BIG ASS FANS User Manuals

Related Manuals