BIG ASS FANS BACF15120B Radiant Infrared Electric Heater Instruction Manual
- June 1, 2024
- BIG ASS FANS
Table of Contents
INSTALLATION, OPERATION
AND MAINTENANCE MANUAL
RADIANT INFRARED ELECTRIC HEATER
BIG ASS FANS
OBSIDIAN®ELECTRIC HEATER
BACF15120B Radiant Infrared Electric Heater
MODELS | MODELS | MODELS | CURRENT(AMPS) |
---|---|---|---|
BACF15120B | BACF15120B | BACF15120B | 12.5 |
FIRE/EXPLOSION HAZARD WARNING
NOT FOR USE IN HAZARDOUS OR EXPLOSIVE ATMOSPHERES
During operation, always ensure combustible materials are kept at a safe
distance from the heater body and from the emitted radiant energy. This heater
is not intended for use in hazardous areas where flammable vapours, gases,
liquids or other combustibles are present. Failure to do so can result in
personal injury/or property damage.
FOR INDOOR AND OUTDOOR COMMERCIAL AND RESIDENTIAL USE
WARNINGS
THIS ELECTRIC APPLIANCE PRODUCES INFRARED HEAT, AND FAILURE TO FOLLOW WARNINGS
AND INSTRUCTIONS CAN CAUSE FIRE, ELECTRIC SHOCK, OR INJURY.
Heater must be installed by a certified electrician and installation must
adhere to all local, state and national electric codes.
READ AND SAVE THESE INSTRUCTIONS
Please read this owner’s manual carefully before using the unit and keep the
manual for future reference.
USE THIS HEATER ONLY AS DESCRIBED IN THIS MANUAL. ANY OTHER USE NOT
RECOMMENDED BY THE MANUFACTURER MAY CAUSE FIRE, ELECTRIC SHOCK OR INJURY TO
PERSONS
Notice: Changes or modifications not approved by the party responsible
for compliance will void the user’s authority to operate the equipment.
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed
to reduce the risk of fire, electric shock, and injury to persons, including
the following outlined in section 1 – SAFETY. Read all instructions before
installing or
using this heater.
SAFETY
WARNINGS
WARNING: FIRE OR EXPLOSTION HAZARD
-
Failure to precisely follow safety warnings could result in serious injury or property damage.
-
Heater has hot surfaces and arcing or sparking parts inside. Do not use the heater in areas where gasoline, paint or flammable vapors or liquids are used or stored.
-
Heater is not to be installed or used in an area containing hazardous or flammable materials including but not limited to rags, fabrics, spray or aerosol cans, cleaning compounds, plastic containers, paper products, organic dusts, straw/hay, gasoline, kerosene, lighter fluid, etc.
-
To prevent a possible fire, do not block air intakes or exhaust in any manner.
-
Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage to the Heater.
Do not cover the heater in any manner, do not hang clothing on or near the heater. -
Caution! Do not use the heater together with another appliance connected to the same supply line or connected to the same breaker.
-
Use the heater with a properly grounded three prong plug.
-
The power cord must not be left on or around the heater body.
-
Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, curtains, etc. at least 6 feet (1.8m) from the front of the heater and keep them away from sides and rear.
WARNING: PERSONAL INJURY HAZARD – OPERATION
-
This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces.
-
Use this heater only as described in this manual.
Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. -
Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
-
Never leave the heater unattended while it is operating.
-
Do not use the heater without the aluminium grille in place.
-
Do not operate any heater after it malfunctions.
Disconnect power at service panel and have heater inspected by an electrician before reusing. -
Do not use the heater to light cigarettes or similar materials.
-
Do not insert objects in heater openings.
Electrical shock could result. -
Connect to properly grounded outlets only. To disconnect heater, turn controls to off, and turn off power to the heater circuit at the main disconnect panel.
WARNING : PERSONAL INJURY HAZARD – CLEANING AND MAINTENANCE
- To avoid property damage, personal injury or death due to electrical shock DO NOT service the unit without turning the unit OFF and disconnecting the heater from the main power supply.
- Before cleaning the unit or replacing the emitter, turn off the main power. Make sure the heater and/or the emitter is cool before handling.
- Service must be performed only by a qualified service technician.
WARNING: INSTALLATION
- This product must be installed by a certified electrician and must adhere to all local, state and national electric codes (NEC)
- Do not direct the radiant part of the heater towards the ceiling.
- Specified minimum clearances from front, sides, bottom and back of unit must be met. Failure to meet clearance minimums can result in fire.
- Heater is not for use in bathrooms, laundry areas or other locations where unit could fall into water.
- Do not use the heater if it has been dropped or damaged in any way. Ensure the emitter is not cracked or chipped visually. Contact an authorized BIG ASS FANS dealer for support.
- Do not use the heater if the power cord is damaged. Contact an authorized servicer or qualified electrician to replace the cord prior to use.
- Unplug the appliance when it is not in use for long periods of time, or for cleaning and maintenance.
- Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
- Heater is not to be recessed
- The heater must be installed at level on a flat, stable surface, rigid enough to safely withstand the weight of the heater and the heater must not be covered by any flexible material, such as carpets, plastic or fabric.
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Heater installation must be carried out by qualified personnel in compliance
with local National Codes (NEC) as well as any other applicable standards.
Failure to comply with applicable requirements could result in personal injury
and/or property damage. Wiring procedures and connections shall be made in
accordance with national and local electrical codes having jurisdiction.
BIG ASS FANS infrared heaters produce radiant heat that warms people and
objects, rather than the air around them. The heater can be wall mounted and
includes brackets which allow the user to direct the infrared heat where
desired.
To reduce the risk of fire, do not store or use gasoline or other flammable
vapors and liquids in the vicinity of the heater.
2.1 INSTALLATION CLEARANCE DISTANCES
DANGER FIRE HAZARD
The minimum clearances indicated on the nameplate and in the user manual must
be observed at the time of installation.
CAUTION : High temperatures are present, risk of fire! Keep electrical
cords, drapery, furnishings and other combustibles at least 6 feet (1.8m) from
the front of the heater and away from the sides and rear.
Minimum Clearance Distances
Floor | Ceiling | Adjacent walls |
---|---|---|
6’7” (2 m) | 1’ (30 cm) | 18” (45 cm) |
Wall Mount Minimum Clearances
2.2 ELECTRICAL INSTALLATION
Safety Precautions
- Each power supply circuit must be properly grounded.
- Use a certified ground fault protection device for wet environment installations.
- Use a proper electrical connection box
- Supply voltage and frequency must correspond to the electrical rating indicated on unit’s information plate
2.3 WALL-MOUNTED INSTALLATION
-
Take the heater out of the box and remove all protective foam inserts.
-
Select the installation location on the wall by identifying the studs or structural beams that will allow the heater to be securely attached.
WARNING : Ensure minimum clearances outlined in section 2.1 are met. -
Securely fasten the L-shaped brackets to the mounting surface using both fixing holes in the short part of the bracket. NOTE: Wall bolts or anchors are not supplied. Select an appropriate size to provide adequate support for the weight of the unit and taking into consideration any wind load conditions.
CAUTION : If there is any question regarding security of the bolts and fixtures, contact a professional contractor. -
Mount the heater to the brackets with the terminal box at the right side of the heater.
-
Adjust the heater to the desired directional angle, then fix in this position by tightening the fixing bolts on the brackets at the back of the heater.
-
Secure the electrical supply cable so it does not contact the heater body or obstruct the air vents.
Follow local and national electrical code requirements.
2.4 ADJUSTING DIRECTIONAL POSITIONING
WARNING
Never attempt to move or adjust the heater angle while it is running. Personal
injury could result.
- Turn off the heaters electrical supply line from the main power supply.
- Allow the heater to cool before adjusting the angle.
- Loosen the fixing bolts on the brackets at the back of the heater; adjust the heater as desired, then retighten the fixing bolts.
Notice : The unit produces radiant heat that warms people and objects rather than the air around them. Install the heater at an angle which points the reflector at the target space. Do not point the heater at windows or vacant spaces, as the heat will not be delivered to the occupants.
OPERATING INSTRUCTIONS
Caution! The heater must be properly installed before it is used.
Caution! When the heater is not in use for extended periods of time, be sure
to set the operating mode to the “OFF” position.
The heater has two modes of operation, these two modes can be selected using
the button on the right side of the heater.
3.1 PCB BYPASS MODE
When the bypass mode is selected, the heater will operate at 100% of rated
power OR may be controlled by other type of external control system. Installer
or specifier is responsible for compatibility and safety of controls not
included with this heater.
3.2 REMOTE MODE
The remote control must be pointed in the direction of the receiver on the
heater body (located on the front face) and must be used within a maximum
distance of 6 m.
In remote mode the heater has 6 power levels. The power level can be selected
with the remote. The selected power level is displayed on the screen on front
of the heater. The remote mode only works with the remote control supplied
with the product. L0 represents standby while L6 represents the maximum
heating level.
| Display| Description| Power setting
---|---|---|---
L1| Heating level 1| 33%
L2| Heating level 2| 50%
L3| Heating level 3| 66%
L4| Heating level 4| 80%
L5| Heating level 5| 88%
L6| Heating level 6| 100%
L0| Standby| 0%
3.2.1 OPERATION OF THE REMOTE CONTROL
| Symbol| Description
---|---|---
˄| Up one heating level
MAX| The heater goes directly to the highest heating level (short delay on
start).
˅| Down one heating level.
ON| To switch the heater ON: Press On.
The heater has a soft start function using only 16% of maximum power. 4
seconds after the heater has been turned
on, it will automatically switch to the last heating level used.
In case of the first-time use, after 4 seconds the heater will automatically
switch to 100% power.
OFF| To switch the heater OFF: Press OFF. The heater will switch to Standby
mode (the receiver indicator will light up).
- Use 2 pieces AAA, 1.5V batteries (not included) in the remote control. Remove the batteries when not in use for an extended period of time to increase battery life.
- The heater can be still used normally in the event the remote control is misplaced, however it must be used in PCB bypass mode where the heater will run fully on. Contact your local authorized BIG ASS FANS Dealer for remote replacement.
- The remote-control function may not work if there is a barrier between the remote control and heater.
- Replace the batteries as required to ensure correct remote functionality.
MAINTENANCE
WARNINGS
- Allow the heater and the emitter to cool down before handling.
- Installation and maintenance must be performed by a qualified technician.
- Turn off the power before beginning maintenance.
- Do not attempt to service or repair the unit while it is running.
- Should the heater be dropped or damaged or malfunction at any time, immediately turn off the main power source and do not use it until it has been examined by an authorized service facility.
Notice : Do not touch the emitter with bare hands. Wearing soft cotton gloves is highly recommended. Finger prints will burn into the carbon emitter during use and cause premature heater failure. If the emitter is inadvertently touched, or if it needs to be cleaned, carefully wipe it using rubbing alcohol or methylated spirits.
4.1 CLEANING
To keep the heater running at peak performance and prevent premature failure,
the emitter lamp and reflector should be cleaned as required. Buildup of dust
on these components will accelerate aging. In seaside environments, salt spray
may collect on these components. Salt spray should be removed regularly.
To clean the reflector or emitter lamp, follow these steps:
- Turn the power to «OFF» and disconnect the heater from the main power supply.
- Remove screws from the left side cover and slide the perforated front grille out of the heater body.
- Carefully wipe the reflector with a soft, lint-free cloth.
- After cleaning, be sure to properly reinstall the heater grille.
4.2 REPLACING THE EMITTER
Contact your distributor for the correct replacement emitter, providing the
model number and rating from the rating label. Using an incorrect replacement
emitter can cause the heater to fail.
Notice: Read through the Emitter replacement procedure below before beginning
the replacement. For easier replacement, remove the heater from the wall or
ceiling.
-
WARNING! TURN OFF THE POWER AND DISCONNECT THE HEATER FROM THE MAIN POWER SUPPLY. FAILURE TO DISCONNECT HEATER BEFORE REPLACING THE EMITTER COULD CAUSE ELECTRIC SHOCK OR DEATH!
-
Be sure the heater and the emitter are cool: burns can result from touching hot components.
-
Remove screws from the left side of the heater fixture and remove the aluminum end cap. (keep these parts).
-
Carefully slide the protective grille out of the heater body to expose the emitter and the plastic sealing connectors.
-
Carefully unscrew the protective plastic cap and carefully slide the cap back cap to expose the wire/ metal connector system.
Caution! Disconnect the metal locking connectors by squeezing the metal tab. -
Bend the metal tabs to remove the small reflector shield sheet metal parts. Hold on to these pieces. This will allow you to slide the emitter into a bigger cavity to remove it from the reflector and heater body. Properly dispose of the broken emitter at your local recycling center.
-
Hold the new emitter by the ceramic ends or wear clean dry gloves to prevent and position the new lamp inside the unit.
-
Insert the new emitter through the reflector openings. Insert the Reflector Shields and bend the tabs back into place. The Reflector Shields hold the emitter in the correct position during operation. It is important that they are reinstalled during emitter replacement.
-
Connect the new emitter to the terminals of the heater; screw in the protective plastic caps
-
Carefully replace the protective aluminum grille and screw the protective end cap in place.
GROUNDING INSTRUCTIONS
WARNING
Connection to GFCI protected outlet is recommended For outdoor, exposed
environments and/or as required by local, state and National Electrical Code
(NEC) requirements.
FAILURE TO USE A GFCI PROTECTED OUTLET COULD RESULT IN FIRE OR ELECTRIC SHOCK!
This heater is for use on 120-volt circuits. The cord has a plug as shown in
image (A) in Figure 60.1 below. An adapter shown at C must be used to connect
three-blade grounding-type plugs to two-slot receptacles. Adapters should not
be used if a three-slot grounded receptacle is available. The green grounding
lug extending from the plug must be connected to a permanent ground such as a
properly grounded outlet box.
NOTE : This heater may be hard wired by a licenced electrician per NEC or
Local codes. To hard wire, a licenced electrician may remove the plug and hard
wire the heater to a properly grounded junction box.
WARNING
Modification of the supplied cord for hardwire purpose may only be
completed by CERTIFIED ELECTRICIANS, and modification must satisfy local and
NEC requirements. Incorrect modifications could result in electric shock or
fire!
Due to ongoing product improvements, specifications and dimensions are subject
to change and correction without notice and without incurring obligations.
Determining the application and suitability for use of any product is the
responsibility of the installer. Additionally, the installer is responsible
for verifying dimensional data on the actual product prior to beginning any
installation preparations.
Incentive and rebate programs have precise requirements as to product
performance and certification. All products meet applicable regulations in
effect on date of manufacture; however, certifications are not necessarily
granted for the life of a product. Therefore, it is the responsibility of the
applicant to determine whether a specific model qualifies for these
incentive/rebate programs.
Manual Revision: A1: 2023-10-18
https://bigassfans.com/product-warranties/
Documents / Resources
| BIG
ASS FANS BACF15120B Radiant Infrared Electric
Heater
[pdf] Instruction Manual
BACF15120B Radiant Infrared Electric Heater, BACF15120B, Radiant Infrared
Electric Heater, Infrared Electric Heater, Electric Heater
---|---
Read User Manual Online (PDF format)