The product is a ceiling fan from bigassfans.com. The fan is available in two models: Universal Mount and Low Profile Mount. The Universal Mount model is compatible with sloped or flat ceilings from 9 to 14 ft (2.7 to 4.3 m) and has a maximum weight of 26 lb (11.8 kg). The Low Profile Mount model is designed for low ceilings. The fan is available in various models with different mounting options, input voltage, and fan diameter ranging from 52 in. (1.3 m) to 84 in. (2.1 m). The fan can be installed in covered outdoor locations but requires light kits marked suitable for use in damp locations.
Product Usage Instructions
Before You Start
- Turn off power at the breaker. If you are uncomfortable performing electrical work, contact a licensed electrician to install the fan if required by local code.
- Gather necessary tools and prepare fan site by checking the ceiling slope, especially for Universal Mount installation.
- Prepare concrete ceiling (if applicable) by removing dust from holes, inserting anchor bolts, striking the heads of anchor bolts with a hammer, positioning mounting bracket, and tightening all anchor bolts fully to expand and lock the anchors.
Universal Mount Installation
- Install the fan stabilizer in covered outdoor locations on flat ceilings only.
- If included, install the EMI filter.
- Remove the lower cover attached to the motor unit.
- Attach the mounting bracket to the ceiling following the specific instructions for your ceiling type (flat or sloped).
- Install the fan by attaching the canopy to the mounting bracket and securing the fan with screws.
- Attach the downrod to the motor unit using the provided screws and steel pin.
- Cover wiring and safety cable with the wiring cover and connect wires using wire connectors.
- Attach the fan blades to the motor unit using the wedge, mounting ball, and screws provided.
- Turn on power at the breaker and test the fan.
Low Profile Mount Installation
Please refer to page 24 of the user manual for Low Profile Mount
installation instructions.
HAIKU®
Installation Guide
Guide d’installation Guía de instalación
bigassfans.com
READ AND SAVE THESE INSTRUCTIONS
SPECIFICATIONS
Universal Mount
Models
Mounting Input Voltage Maximum Weight
MK-HK4-042406, MK-HK4-041806, MK-HK4-042506, MK-HK4-052406, MK-HK4-051806, MK-
HK4-052506, MK-HK4-071806, MK-HK4-071906, MK-HK4-04240601, MK-HK4-04180601,
MK-HK4-05240601, MK-HK4-05180601, MK-HK4-07180601
Sloped or flat ceilings from 9 to 14 ft (2.7 to 4.3 m)
100240 VAC, 1 , 5060 Hz
26 lb (11.8 kg)
Low Profile Mount
Models
Mounting Input Voltage Maximum Weight
MK-HK4-042400, MK-HK4-042500, MK-HK4-052400, MK-HK4-052500, MK-HK4-04240001, MK-HK4-05240001 Flat ceilings from 8 to 10 ft (2.4 to 3 m) 100240 VAC, 1 , 5060 Hz 18.5 lb (8.4 kg)
1
BEFORE YOU START
Turn Off Power at Breaker
Contact an electrician if you are uncomfortable performing electrical work. A
licensed electrician must install the fan if required by local code.
Gather Tools
Prepare Fan Site and Gather Hardware CAUTION
Do not use the fan with a dimmer switch. Outlet Box: Make sure your outlet
box is suitable for fan support. If there is not an outlet box at the fan
location, install one on a ceiling joist or beam. You will need to supply two
10-32 screws for attaching the fan mounting bracket or plate to the outlet
box. Concrete Ceiling: Depending on your mount type, you will need to supply
three or four anchor bolts for attaching the fan mounting bracket or plate
to the ceiling. If required by your local building and safety codes, you will
also need to supply an anchor hook for the safety cable. See pages 45 for
hardware specifications and installation details. Wood Ceiling Joist: You
will need to supply two corrosion-resistant 12-11 x 45 mm hex head timber
screws with seal for attaching the fan mounting bracket or plate directly to
the joist. If required by local code, mount or embed an outlet box into the
joist. The outlet box must be suitable for fan support. Covered Outdoor
Locations: Damp-rated fans installed in covered outdoor locations must have
fixed/permanent full overhead coverage extending at least 2 ft (0.6 m) out
from the airfoil tips on all sides.
Mounting to an outlet box or a wood ceiling joist is not applicable in Singapore. If anchor bolts and anchor hook are included with your fan, use them for concrete mounting. ***When installing the fan in a covered outdoor location, use only light kits marked “Suitable for Use in Damp Locations.”
2
BEFORE YOU START
Check Ceiling Slope (Universal Mount)
Consult the table below to make sure you have the appropriate downrod length
for your ceiling slope. Universal Mount fans can be installed on flat or
sloped ceilings with an angle no greater than 33° (approximately 8:12 roof
pitch). For minimum clearance guidelines, consult the Important Safety
Instructions booklet included with this installation guide.
Ceiling Height
910 ft (2.73 m)
1011 ft (33.4 m)
1113 ft (3.44 m)
1314 ft (44.3 m)
14 ft (>4.3 m)
Fan Diameter
52 in. (1.3 m)
60 in. (1.5 m)
84 in. (2.1 m) 52 in. (1.3 m) 60 in. (1.5 m) 84 in. (2.1 m) 52 in. (1.3 m) 60
in. (1.5 m) 84 in. (2.1 m) 52 in. (1.3 m) 60 in. (1.5 m) 84 in. (2.1 m) 52 in.
(1.3 m) 60 in. (1.5 m) 84 in. (2.1 m)
Downrod Length* 7 in. (178 mm) 12 in. (305 mm) 7 in. (178 mm) 12 in. (305 mm)
12 in. (305 mm)
20 in. (508 mm)
32 in. (813 mm)
48 in. (1219 mm)
60 in. (1524 mm)
Maximum Ceiling Slope (Indoor Only)**
Flat 12° Flat 10° Flat 26° 22° 16° 33° 33° 29°
33°
33°
*7-in. (178-mm) downrod not available for 84-in. (2.1-m) fans. Damp-rated fans installed in covered outdoor locations can be mounted to flat ceilings only. Mounting to a sloped ceiling is not applicable in Singapore.
3
BEFORE YOU START
Prepare Concrete Ceiling (if applicable)
Universal Mount Drill three Ø 8 mm holes in the pattern shown (Fig. 1). The
hole depth should not exceed 46 mm (Fig. 2).
Remove dust from holes. Insert anchor bolts into holes. Strike the heads of
the anchor bolts with a hammer, ensuring bolt sleeves are flush with ceiling
surface. Position mounting bracket on anchor bolts. Ensure all anchor bolts
are fully tightened to expand and lock the anchors.
If required by local building and safety codes, install an anchor hook for
the safety cable. Drill an Ø 8 mm hole for the anchor hook. The hole depth
should not exceed 46 mm (Fig. 2). Remove dust from hole, and then insert the
anchor hook and fully tighten.
Fig. 1
Ø 8 mm
112 mm
46 mm max 46 mm max
45 mm 43 mm
Fig. 2
*Applicable for Singapore: Anchor bolts and anchor hook are included with your fan. Use them for concrete mounting.
4
40 mm
Ø 8 mm (anchor bolt)
BEFORE YOU START Low Profile Mount Drill four Ø 8 mm holes in the pattern
shown (Fig. 1). The hole depth should not exceed 46 mm (Fig. 2). Remove dust
from holes. Insert anchor bolts into holes. Strike the heads of the anchor
bolts with a hammer, ensuring bolt sleeves are flush with ceiling surface.
Position mounting plate on anchor bolts. Ensure all anchor bolts are fully
tightened to expand and lock the anchors. If required by local building and
safety codes, install an anchor hook for the safety cable. Drill an Ø 8 mm
hole for the anchor hook. The hole depth should not exceed 46 mm (Fig. 2).
Remove dust from hole, and then insert the anchor hook and fully tighten.
Fig. 1
100 mm
Ø 8 mm (anchor hook)
Fig. 2
*Applicable for Singapore: Anchor bolts and anchor hook are included with your fan. Use them for concrete mounting.
5
80 mm
46 mm max 46 mm max
UNIVERSAL MOUNT INSTALLATION
For Low Profile Mount installation, see page 24.
Install fan stabilizer in covered outdoor locations on flat ceilings only.
An EMI filter (not shown) is included for certain regions and fan diameters.
If the EMI filter is included, install it with your fan.
The lower cover is shipped attached to the motor unit to protect the fan’s
internal electronics during installation.
Mounting Bracket
Fan Stabilizer, M6 x 70 mm Bolt, M6 Nut (Included only with damp-rated fans.)
(4) M4 x 6 mm Screws
Wire Connectors
Wiring Cover
4 mm Screw, Wedge, Mounting Ball
Canopy
6 mm Steel Pin
Downrod
Wiring and Safety Cable M6 x 32 mm Bolt
Uplight* (Optional, indoor fans only)
(6) M5 Screws
M6 Nut
Motor Unit (3) Airfoils (6) Grommets
*Not applicable for Singapore.
6
Lower Cover OR Downlight (Optional)
Hardware included
Airfoil HardwareStep 1
UNIVERSAL MOUNT INSTALLATION
x6
x6
Grommet
M5 Screw
Lower Mounting HardwareStep 2
x1
M6 x 32 mm Bolt
x1
M6 Nut
Lower Mounting HardwareStep 3
x2
M4 x 10 mm Screw
x2
M4 Lock Washer
Upper Mounting HardwareStep 8
x1
6 mm Steel Pin
Fan Stabilizer Hardware*Step 12
x1
4 mm Screw
x1
Wedge
x1
M6 x 70 mm Bolt
Safety Cable ShackleStep 13
x1
x1
M6 Nut
Upper Mounting HardwareStep 14
x4
M4 x 6 mm Screw
Shackle
*Included only with damp-rated fans.
7
UNIVERSAL MOUNT INSTALLATION
1. Install airfoils
Make sure the sticker color on each airfoil matches the corresponding sticker
color on the motor unit.
Moving clockwise, slide each airfoil edge under the lower cover, align the
mounting holes with the holes on the motor unit, and secure with the airfoil
hardware. Make sure the grommets are positioned correctly in the holes (Fig.
1).
Fig. 1
Grommet
M5 Screw
Airfoil
8
UNIVERSAL MOUNT INSTALLATION
2. Install downrod
No Uplight
If not installing an uplight, align holes on downrod with holes on motor
bracket. Position downrod wiring harness so that it is on the same side of the
motor shaft as the motor unit wiring harness. Position ground wire and safety
cable so that they are on the opposite side of the motor shaft as the motor
unit wiring harness. Secure downrod with the lower mounting hardware (Fig.
2a).
Fig. 2a
Downrod Wiring Harness
M6 Nut
M6 x 32 mm Bolt
Motor Unit Wiring Harness
Ground Wire and Safety Cable
Uplight
Align holes on downrod with holes on motor bracket. Position downrod wiring
harness, ground wire, and safety cable so that they are on the opposite side
of the motor shaft as the motor unit wiring harness. Secure downrod with the
lower mounting hardware (Fig. 2b).
Fig. 2b
Motor Unit Wiring Harness
M6 Nut
M6 x 32 mm Bolt
Downrod Wiring Harness
Ground Wire and Safety Cable
9
UNIVERSAL MOUNT INSTALLATION
3. Install lower safety cable and ground wire
Install safety cable and ground wire lugs with unpainted screws and lock
washers (Fig. 3).
Fig. 3
M4 Lock Washer
M4 x 10 mm Screw
Ground Wire (Green/Yellow)
Safety Cable
4. Install uplight (optional)
Skip this step if you are not installing an uplight. Make sure wiring
harnesses are as close to downrod as possible so that they do not interfere
with uplight installation (Fig 4.1).
Fig. 4.1
10
UNIVERSAL MOUNT INSTALLATION
Skip this step if you are not installing an uplight. If you purchased the UV-C
option, install the UV-C LED boards on the uplight before installing the
uplight on the fan. Refer to the instructions packaged with the UV-C LED
boards. Align rectangular cutouts in center of uplight with bolts on downrod.
Make sure uplight wiring harness and motor unit wiring harness are on opposite
sides of downrod. Slide uplight down the downrod until it stops (Fig 4.2).
There will be some space between the uplight and the top of the motor unit.
Fig. 4.2
Uplight not compatible with damp-rated fans. Light kit weight: 1.5 lb (680 g).
11
UNIVERSAL MOUNT INSTALLATION
5. Connect wiring harnesses
No Uplight If not installing an uplight, connect downrod wiring harness to
motor unit wiring harness (Fig. 5a).
Fig. 5a
Downrod Wiring Harness
Motor Unit Wiring Harness
Uplight Tighten the two set screws at top of uplight. Connect uplight wiring
harness to motor unit wiring harness. Connect downrod wiring harness to
receptacle on uplight (Fig. 5b).
Fig. 5b
Uplight Wiring Harness to Motor Unit Wiring Harness
Downrod Wiring Harness to Uplight Receptacle
12
UNIVERSAL MOUNT INSTALLATION
6. Reduce slack
Make sure all hardware is secure, and then gently tug cables at top of downrod
to reduce slack (Fig. 6). Make sure rubber plug at top of downrod stays in
place.
Fig. 6
7. Position wiring cover and canopy
Slide wiring cover down the downrod, resting it on the motor unit or uplight.
Make sure no wires are visible. Slide canopy down the downrod, resting it on
the wiring cover (Fig. 7).
Fig. 7
Canopy
Wiring Cover
13
UNIVERSAL MOUNT INSTALLATION
8. Install mounting ball
Do not over-tighten the mounting ball screw.
Slide mounting ball over downrod (Fig. 8.1).
Insert 6 mm steel pin into hole at top of downrod, and then slide the mounting
ball upward, seating the steel pin in the inner slots (Fig. 8.2).
Insert wedge into mounting ball and secure with screw (Fig. 8.3). Tighten
screw enough to prevent movement between the mounting ball and downrod, but do
not overtighten. Make sure rubber plug at top of downrod is still in place.
Fig. 8.1
Fig. 8.2
Mounting Ball
6 mm Steel Pin
Downrod
Fig. 8.3
4 mm Screw Wedge
14
UNIVERSAL MOUNT INSTALLATION
9. Install mounting bracket WARNING
Disconnect power to fan location before installing mounting bracket. Mount
only to an outlet box marked acceptable for fan support.
Secure mounting bracket to mounting structure with suitable hardware (not
supplied) (Fig. 9). Outlet box shown. Your mounting structure may differ.
Mounting bracket power supply omitted from illustration for visual clarity.
Fig. 9
Mounting Bracket
10. Hang fan
Raise fan to mounting bracket. Align rib in mounting bracket with slot in
mounting ball, position mounting ball, and let fan hang freely (Fig. 10).
Gently twist downrod to ensure it is properly seated and will not move during
fan operation.
Mounting Ball
Suitable Mounting Hardware (not supplied)
Mounting Bracket
Fig. 10 15
UNIVERSAL MOUNT INSTALLATION
11. Wire fan
WARNING
Disconnect power to fan location before wiring fan. Do not connect fan to a
damaged power source. Do not attempt to resolve electrical failures on your
own. Consult a qualified electrician if uncertain of the electrical
installation of this fan.
Wire fan as shown on the following pages using the wire connectors. If your
fan packaging did not include an EMI filter*, refer to Fig. 11a. If your fan
packaging included an EMI filter, refer to Fig. 11b. The EMI filter is
included only for certain regions and fan diameters.
Attach green and yellow ground wire to mounting bracket with the unpainted
screw. Connect wiring harness from power supply to wiring harness from
downrod, making sure that the wiring and safety cable are routed in the same
direction.
Carefully tuck wiring into outlet box or building structure. Ensure wire
connectors are turned upward and that wires are spread apart with grounded
conductors on one side of the outlet box/mounting structure and ungrounded
conductors on the other side.
Supply Power Wire Colors
AC Hot/L1 Brown
AC Neutral/L2 Blue
PE/Earth Ground Green with Yellow
North America 100120 V
Black
White
Green or Bare Copper
Australia
All other regions
Brown or Red
Brown
Black or Light Blue
Blue
Green with Yellow Green with Yellow
Wire Connector Operation
1
2
*EMI filter is supplied in MK-HK4-071806, MK-HK4-071906, and MK-HK4-07180601.
16
UNIVERSAL MOUNT INSTALLATION Fig. 11a: Wiring Diagram (No EMI Filter)
RED AC HOT/L1 BROWN
Power Supply
AC NEUTRAL/ L2
PE/EARTH GROUND
GREEN & YELLOW BLUE
Mounting Bracket
Safety Cable
Wiring Harnesses
17
UNIVERSAL MOUNT INSTALLATION Fig. 11b: Wiring Diagram (With EMI Filter)
The EMI filter is included only for certain regions and fan diameters.
AC HOT/L1
BLUE EMI Filter
RED AC NEUTRAL/ L2
PE/EARTH GROUND
BROWN
Power Supply
GREEN & YELLOW
Mounting Bracket
Safety Cable
Wiring Harnesses
18
UNIVERSAL MOUNT INSTALLATION
12. Install fan stabilizer (if included)
Fan stabilizer is included only with damp-rated fans. Install stabilizer in
covered outdoor locations on flat ceilings only. Position stabilizer into
notches on top of mounting ball (Fig. 12.1). Secure stabilizer plate to
stabilizer with fan stabilizer hardware (Fig. 12.2).
Stabilizer
Mounting Ball
Fig. 12.1
Stabilizer Plate
M6 x 70 mm Bolt
M6 Nut
Fig. 12.2 19
UNIVERSAL MOUNT INSTALLATION
13. Secure safety cable
Some local safety codes require the safety cable to be secured directly to an
existing part of the building structure (Canada, Singapore). It may be
necessary to install additional structural material to provide attachment
points. Check your local safety code if you are unsure. Mounting Bracket (not
applicable for Singapore) Loop safety cable around mounting bracket and secure
with shackle (Fig. 13a).
Shackle Safety Cable
Fig. 13a
Anchor Hook (applicable for Singapore) Loop safety cable around anchor hook
and secure with shackle (Fig. 13b).
Fig. 13b
Shackle
20
Safety Cable
UNIVERSAL MOUNT INSTALLATION
Building Structure (not applicable for Singapore) Loop safety cable around
building structure and secure with shackle (Fig. 13c). Acceptable building
structures include a wooden beam or a metal mounting brace secured between two
beams. In some cases, it may be necessary to install additional structural
material to provide attachment points.
Fig. 13c
Safety Cable
Shackle
14. Raise canopy
Raise canopy to mounting bracket, aligning the four holes on the canopy with
the holes on the bracket. Secure canopy to mounting bracket with the painted
screws (Fig. 14). Make sure all wires and the safety cable are tucked in the
canopy.
Fig. 14
Canopy
M4 x 6 mm Screw
21
UNIVERSAL MOUNT INSTALLATION
15. Install downlight (optional) CAUTION
To reduce the risk of electric shock, disconnect power to fan before
installing downlight. Remove lower cover from bottom of motor unit by twisting
counterclockwise (Fig 15.1). Save the lower cover. Reinstall it if you later
uninstall the downlight. Plug downlight wiring harness into receptacle on
bottom of motor unit. Align slots on downlight with tabs on bottom of motor
unit and twist downlight clockwise to secure in place (Fig. 15.2).
Fig. 15.1
Lower Cover
Fig. 15.2
Downlight Use only light kit model 010593. Light kit weight: 2 lb (907 g).
22
UNIVERSAL MOUNT INSTALLATION
16. Test fan
CAUTION
Do not expose the remote control to rain or water.
Congratulations! Installation is now complete. Turn on power, and then press
any button on the remote control to pair it with your fan. Test your fan using
the remote (Fig. 16). Note: It is normal for the fan to jerk forward and
backward slightly for a few seconds when first turned on.
Fig. 16
Fan On/Off
Adjust Fan Speed
Light(s) On/Off (if installed)
Adjust Light Brightness (if installed)
Press Auto to enable motion sensing and automatic fan speed adjustment as room
conditions change. To adjust your Auto preferences, download the Big Ass Fans
mobile app. Press and hold to toggle between lighting control options: ·
Uplight · Downlight · Both lights simultaneously To change the LED color
(uplight only) or color temperature or to turn on the uplight’s UV-C option
(if installed), download the Big Ass Fans mobile app. Note: The UV-C option
will only turn on while the fan is spinning.
Automate your comfort with SenseME®
SenseME automatically adjusts your fans and lights to keep your home feeling
and looking exactly the way you want it to. Download the Big Ass Fans mobile
app to group multiple fans, adjust their settings, and set your comfort
preferences for hands-free control. For smart device integration instructions,
visit www.bigassfans.com/support
23
LOW PROFILE MOUNT INSTALLATION
For Universal Mount installation, see page 6.
Use the two downtube screw caps that match the color of your fan. The lower
cover is shipped attached to the motor unit to protect the fan’s internal
electronics during installation.
Mounting Plate
Wiring and Safety Cable (2) Mounting Brackets (4) 6 mm Nylock Nuts
(2) Rubber Bumpers Wiring Cover Trim
(2) Downtube Screw Caps
Wire Connectors
Wiring Cover
(2) 5/16″ Screws
Motor Unit (3) Airfoils
(6) Grommets (6) M5 Screws
Lower Cover OR
Downlight (Optional)
24
Hardware included
Airfoil HardwareStep 1
x6
M5 Screw
LOW PROFILE MOUNT INSTALLATION
x6
Grommet
Mounting HardwareStep 4, Step 8
x4
6 mm Nylock Nut
Safety Cable ShackleStep 6
x1
Shackle
Wiring Cover Screws and Downtube Screw CapsStep 9
x3
5/16″ Screw*
x8
Downtube Screw Cap**
*One spare screw is included. **Use the two screw caps that match the color of your fan.
25
LOW PROFILE MOUNT INSTALLATION
1. Install airfoils
Make sure the sticker color on each airfoil matches the corresponding sticker
color on the motor unit.
Moving clockwise, slide each airfoil edge under the lower cover, align the
mounting holes with the holes on the motor unit, and secure with the airfoil
hardware. Make sure the grommets are positioned correctly in the holes (Fig.
1).
Fig. 1
Grommet
M5 Screw
Airfoil
2. Install rubber bumpers
Slide rubber bumpers onto downtube brackets (Fig. 2).
Fig. 2
Downtube Brackets
Rubber Bumper
26
LOW PROFILE MOUNT INSTALLATION
3. Install mounting plate WARNING
Disconnect power to fan location before installing mounting plate. Mount only
to an outlet box marked acceptable for fan support. Secure mounting plate to
mounting structure with suitable hardware (not supplied) (Fig. 3). Outlet box
shown. Your mounting structure may differ. Fig. 3
Mounting Plate
Suitable Mounting Hardware (not supplied)
4. Install single mounting bracket
Loosely attach one mounting bracket to the mounting plate with two 6 mm nylock
nuts, but do not fully tighten (Fig. 4).
Fig. 4
Mounting Plate
Mounting Bracket
6 mm Nylock Nut
27
LOW PROFILE MOUNT INSTALLATION
5. Hang fan
Raise fan to mounting plate and temporarily rest one rubber bumper in the
space between the mounting bracket and mounting plate (Fig. 5).
Fig. 5
6. Secure safety cable
Two people are recommended for this step, or the fan should be placed upright
on a stable surface during this step to allow both hands to be free for
securing the safety cable. Some local safety codes require the safety cable to
be secured directly to an existing part of the building structure (Canada,
Singapore). It may be necessary to install additional structural material to
provide attachment points. Check your local safety code if you are unsure.
28
LOW PROFILE MOUNT INSTALLATION
Mounting Plate (not applicable for Singapore) While supporting the fan, loop
safety cable around mounting plate and secure with shackle (Fig. 6a).
Fig. 6a
Mounting Plate
Safety Cable Shackle
Anchor Hook (applicable for Singapore) While supporting the fan, loop safety
cable around anchor hook and secure with shackle (Fig. 6b).
Fig. 6b
Shackle
Safety Cable
29
LOW PROFILE MOUNT INSTALLATION
Building Structure (not applicable for Singapore) While supporting the fan,
loop safety cable around building structure and secure with shackle (Fig. 6c).
Acceptable building structures include a wooden beam or a metal mounting brace
secured between two beams. In some cases, it may be necessary to install
additional structural material to provide attachment points.
Fig. 6c
Safety Cable
Shackle
7. Wire fan
WARNING
Disconnect power to fan location before wiring fan. Do not connect fan to a
damaged power source. Do not attempt to resolve electrical failures on your
own. Consult a qualified electrician if uncertain of the electrical
installation of this fan.
Allow fan to hang from safety cable. Wire fan as shown on the following page
using the wire connectors (Fig. 7).
Carefully tuck wiring into outlet box or building structure. Ensure wire
connectors are turned upward and that wires are spread apart with grounded
conductors on one side of the outlet box/mounting structure and ungrounded
conductors on the other side.
Wire Connector Operation
1
2
30
Fig. 7
LOW PROFILE MOUNT INSTALLATION
RED AC HOT/L1
AC NEUTRAL/L2
PE/EARTH GROUND
BROWN
BLUE GREEN & YELLOW
Supply Power Wire Colors
AC Hot/L1 Brown
AC Neutral/L2 Blue
PE/Earth Ground Green with Yellow
North America 100120 V
Black
White
Green or Bare Copper
Australia
All other regions
Brown or Red
Brown
Black or Light Blue
Blue
Green with Yellow Green with Yellow
31
LOW PROFILE MOUNT INSTALLATION
8. Secure mounting brackets
Raise fan to mounting plate. Insert one rubber bumper between the mounting
plate and the loosely installed mounting bracket. Secure the other bumper with
the remaining mounting bracket and 6 mm nylock nuts (Fig. 8). Tighten all four
nuts with a wrench until snug.
Fig. 8
Mounting Bracket
6 mm Nylock Nut
9. Install wiring cover and screw caps
Raise wiring cover, allowing about a 1/8″ (3 mm) gap at ceiling. Align
mounting slots with screw holes on downtube and secure wiring cover with the
wiring cover screws (Fig. 9). Slide wiring cover trim up downtube, aligning
the inside tabs with the slots on the bottom of the wiring cover. Twist trim
clockwise to secure in place (Fig. 9). Insert the two downtube screw caps that
match the color of your fan into the screw holes at the bottom of the downtube
(Fig. 9).
Fig. 9
Wiring Cover
5/16″ Screw
Wiring Cover Trim
Downtube Screw Cap
32
LOW PROFILE MOUNT INSTALLATION
10. Install downlight (optional) CAUTION
To reduce the risk of electric shock, disconnect power to fan before
installing downlight. Remove lower cover from bottom of motor unit by twisting
counterclockwise (Fig 10.1). Save the lower cover. Reinstall it if you later
uninstall the downlight. Plug downlight wiring harness into receptacle on
bottom of motor unit. Align slots on downlight with tabs on bottom of motor
unit and twist downlight clockwise to secure in place (Fig. 10.2).
Fig. 10.1
Lower Cover
Fig. 10.2
Downlight
Use only light kit model 010593. Light kit weight: 2 lb (907 g).
33
LOW PROFILE MOUNT INSTALLATION
11. Test fan
CAUTION
Do not expose the remote control to rain or water.
Congratulations! Installation is now complete. Turn on power, and then press
any button on the remote control to pair it with your fan. Test your fan using
the remote (Fig. 11). Note: It is normal for the fan to jerk forward and
backward slightly for a few seconds when first turned on.
Fig. 11
Fan On/Off
Adjust Fan Speed
Light On/Off (if installed)
Adjust Light Brightness (if installed)
Press Auto to enable motion sensing and automatic fan speed adjustment as room
conditions change. To adjust your Auto preferences, download the Big Ass Fans
mobile app. To change the downlight’s color temperature, download the Big Ass
Fans mobile app.
Automate your comfort with SenseME®
SenseME automatically adjusts your fans and lights to keep your home feeling
and looking exactly the way you want it to. Download the Big Ass Fans mobile
app to group multiple fans, adjust their settings, and set your comfort
preferences for hands-free control. For smart device integration instructions,
visit www.bigassfans.com/support
34
TROUBLESHOOTING
Issue
Solution
This is normal and may happen occasionally upon The fan jerks upon startup.
startup. An initial slight jerking forward and backward
does not affect fan operation.
The fan will not start.
· Make sure the fan is receiving power. Check your circuit breaker or fuse
panel and wall switch for functionality.
· Make sure supply power is adequate. · Make sure all wires are securely
connected and the
fan is properly wired and grounded. · Make sure the plastic film in the
remote’s battery tray
has been removed.
The fan wobbles.
· Make sure all mounting hardware is secure and tight. · Remove the airfoils
and make sure the colored dot
sticker on each airfoil matches the corresponding sticker on the motor unit.
If the stickers do not match, move the airfoils to the matching attachment
points. · If you installed multiple fans, make sure the serial numbers on the
airfoils match the serial number on the motor unit. · Make sure all airfoils
are aligned properly and are securely fastened to the motor unit. · If an
airfoil is damaged, contact Customer Service. Airfoils must be replaced as a
set. Do not replace individual airfoils. · Universal Mount only: Make sure the
downrod and motor unit are hanging straight. Raise the wiring cover and locate
the two bolts and nuts on the motor bracket. Loosen the hardware slightly to
allow the fan to hang straight, and then re-tighten just past hand tight.
Slide the wiring cover back in place.
35
TROUBLESHOOTING Issue
Solution
Remove the downtube screw caps and locate the pivot bolt on the downtube.
Loosen the bolt with a 5 mm hex key to allow the fan to hang straight, and
then re-tighten. Reinstall the screw caps.
The fan appears slightly tilted.
(Low Profile Mount only)
The fan is noisy during operation.
I need to reboot the fan.
Bring the fan to a complete stop. · Gently turn the airfoils by hand, making
sure there
are no fan parts rubbing on the hub when the fan rotates. · Check all mounting
and fan hardware. If loose, tighten.
Press and hold the remote On/Off button until the LED indicators start
blinking. Within three seconds of the LEDs blinking, press the On/Off button
again. When the LEDs stop blinking, the reboot is complete.
I need to pair my remote control with a different fan.
To pair a remote with a different fan, press and until the LEDs blink. Make sure the remote is within range of the new fan, and then press any button to pair.
The green LED on the downlight is blinking or the downlight is not responding.
This can occur when the downlight experiences an electrostatic discharge. Use the remote to reboot the fan or turn power to the fan off and back on.
36
MAINTENANCE
WARNING
Risk of fire, electric shock, or injury to persons during cleaning and user
maintenance. Disconnect the appliance from the power supply before servicing.
Please take a few moments each year to perform the following preventative
maintenance procedures on your fan to ensure its safe and efficient operation.
Check the safety cable, hardware, and wiring
Check that the safety cable is properly installed by removing the canopy or
wiring cover screws, sliding the canopy or wiring cover down the downrod or
downtube, and examining the safety cable and hardware.
Make sure the mounting hardware and the screws securing the airfoils to the
motor unit are securely fastened.
Make sure the wire connectors are secure and the ground wire is securely
connected.
Clean the airfoils
Dust the airfoils regularly. If the fan becomes dirty, clean it with a soft
cloth. Do not use solvents, gasoline, or any other chemical cleaners. These
may cause surface distortion and damage to the fan.
Clean the lights
Downlight: Clean the light’s lens periodically to ensure optimal performance.
Wipe the lens with a soft cloth. If necessary, use water and a mild soap or a
gentle liquid cleaner. Do not clean the light or lens with scouring pads,
alkaline cleaning substances, gasoline, thinner, benzene, heating oil, or
polishing powder. Uplight: Clean the LEDs periodically to ensure optimal
performance. Use a compressed air duster to remove dust and debris from the
LEDs. Do not touch the LEDs while cleaning. Hold the duster can upright when
using.
For more operation, maintenance, and troubleshooting information, visit
www.bigassfans.com/support
37
CONTACT US
United States 2348 Innovation Drive Lexington, KY 40511 USA 877-244-3267
Outside the U.S. (+1 859-233-1271) bigassfans.com
Australia 35 French Street Eagle Farm, Brisbane QLD 4009 Australia +61 1300
244 277 bigassfans.com/au
Manufacturer 2348 Innovation Drive Lexington, KY 40511 USA
Manufacturing Site 2251 Innovation Drive Lexington, KY 40511 USA
Warranty and WEEE Returns 2201 Jaggie Fox Way Lexington, KY 40511 USA
Canada 2180 Winston Park Drive Oakville, Ontario L6H 5W1 Canada 1 844-924-4277
bigassfans.com/ca
Singapore 50 Ubi Crescent #01-01 Ubi TechPark Singapore 408568 +65 6709 8500
bigassfans.com/sg
Mexico CEBSA (Corporación Eléctrica del Bravo SA de CV) Avenida Ind. Rio San
Juan Lote 3-A Parque Industrial del Norte Reynosa, Tamps C.P. 88736 +52 1 899
925 6398 http://cebsainc.com/
All Other Geographies +1 859-410-6286 bigassfans.com
EPA Est. 97457-KY-1 The information contained in this document is subject to change without notice. For the most up-to-date information, see the online printable installation guide at www.bigassfans.com/support Haiku® is a trademark of Delta T LLC, registered in the U.S. and/or other countries. Google Play is a trademark of Google LLC. www.bigassfans.com/patents www.bigassfans.com/product-warranties © 2022 DELTA T LLC. ALL RIGHTS RESERVED.
References
- Big Ass Fans
- Big Ass Fans Australia - Comfort Solutions For Your Home or Business
- Canada HVLS & Overhead Ceiling Fans - Big Ass Fans
- Big Ass Fans - Comfort Solutions For Your Home or Business
- Home | CEBSA
- Patents - Big Ass Fans®
- Product Warranties - Big Ass Fans®
- Support - Big Ass Fans®
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>