Conas ML3501L Surface Mounted Electromagnet User Guide
- June 1, 2024
- Conas
Table of Contents
Conas ML3501L Surface Mounted Electromagnet
Magnetic Lock(350kg)
Specification
Diagram(unit:mm)
Installation
-
Fold the plate to 90°
-
Close the door first, then place the upper side of template on door frame, while adjust the left side next to the door leaf.
-
Mark screw positions of armature plate and magnetic lock on door leaf and door frame respectively.
-
Drill holes based on the marked positions.
-
Make a combination .based on the picture.
-
Strike the pin into the armature plate slightly (to avoid movement).
-
Make a combination based on the picture(add washer accordingly). The rubber ring must be added.
-
Place the rubber ring between armature plate and door leaf.
-
Use Allen key to remove the mounting plate from lock body.
-
Fix the mounting plate on the door frame according to the holes drilled earlier.
-
Use Allen key to screw the lock body on the mounting plate.
-
Close the door to test holding force. The angle between armature plate and magnetic lock can be adjusted by adding or reducing washers.
-
After all the appropriate procedures, the holding force can be maximized. Finally, fix the tamper screw.
-
Drill a hole
Inside: Diameter is 8mm Outside: Diameter is16mm -
Drill a hole
Inside: Diameter is 8mm Outside: Diameter is 12.7mm -
Inside: Drill a hole diameter is 8mm folding the plastic straight pin
Notice:
Thickness of Door Leaf: 360LBS: 44mm 600lBS: 50mm 800LBS: 48mm 1200LBS: 46mm
- The screw of armature plate should not be fixed too light. Proper elastically should be guaranteed for the robber ring so that the armature plate can adjust it self to the appropriate position,
- Check the jumper’s position before connecting: Figure out it represents 12VDC or 24VDG
Bracket Installation
Different brackets are available according to different types of doors. For example, narrow door , frameless glass door and inward opening door.
-
L Bracket-For outward opening door
When the door frame thickness is less than 42mm, L bracket is needed. -
ZL Bracket-For inward opening door
For inward opening door, ZL bracket is needed. -
U Bracket
For the frameless glass door. U bracket is needed. -
I Bracket for armature plate
When the door frame is too thick, I bracket is needed.
Installation Instruction
- Demonstration of I Bracket Installation
- : Demonstration of L Bracket Installation
- Demonstration of ZL Bracket Installation
- Demonstration of U Bracket Installation
Circuit Board Diagram
- 12VDC Input:
- Connect the positive(+)lead from a 12VDC power source to V +.
- Connect the ground(-)lead from a 12VDC power source to V -.
- Check jumper for 12 VDC operation.
- 24VDC Input:
- Connect the positive(+)lead from a 24VDC power source to V +.
- Connect the ground(-)lead from a 24VDC power source to V -.
- Check jumper for 24 VDC operation.
- Connection: green wire or white plug, except the models without LED indicator and signal output; only when it detects that double doors have been locked, there will be normal signal output. ‘
Wire Connection
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>