easee BPR2W001 Base Charging Pedestal PR 2-Way User Guide
- June 5, 2024
- easee
Table of Contents
User guide/Installation guide
Easee Base
1-Way/2-Way
IMPORTANT: Read carefully before use. Keep for future reference.
Introduction
Easee Base The Easee Base is a modular charging post for mounting up to four
Easee Charging Robots.
With Easee Base, it is possible to choose between multiple configurations:
1-Way setup, where only one charger is mounted; 2-Way setup, with two
chargers; and Multi-Way setup, with up to 4 chargers installed.
With multiple configurations in one design, they share many common parts. Only
a few parts are specific to each type of layout.
Conventions
| This symbol indicates that the respective instructions must only be carried
out by an authorized electrician.
---|---
| This symbol indicates an immediate danger to the life and health of
individuals due to the effects of electrical energy. Non-observance of these
instructions will result in serious damage to health – up to and including
life-threatening injuries.
Technical specifications
General
Dimension (mm): H: 1500 x W: 160 x D: 80
Weight: 6.1–7.7 kg
Material: Aluminium
Finish: Powder coating
Colour: Black
IP degree: IP44
Features
Adapter plate for c/c 160 mm foundation
45-degree rotation intervals (using the adapter plate)
Screws and nuts included
Electrical connection
Connection via Power Rail
Possibility of the serial connection of posts
Cable size
In and out of the post: Max 25 mm²
Up to the chargers: 6 mm²
Cable length (between chargers and Power Rail): 135 cm
Safety instructions
Read the entire manual carefully before installing and operating the
product. Observe the following instructions:
Safety instructions for the installation
- This product shall only be installed, repaired, or serviced by an authorized electrician. All applicable local, regional and national regulations for electrical installations must be respected.
- Danger to life due to high electrical voltage. Never make any changes to components or connecting cables.
- The installation must not be carried out in the vicinity of explosive atmospheres or in areas where there is a risk of flowing water.
- The product must be installed in a permanent location.
- The terminals in the backplate are energized when the power circuit is closed and must never be in direct contact or in contact with anything other than the plug-in electronics (Chargeberry).
- Depending on the type of installation, official authorizations may be required prior to installation.
Safety instructions for operation
- Danger to life due to high electrical voltage. Never make any changes to components or connecting cables.
- Always have the prescribed maintenance, installation, and any repair work carried out by an authorized electrician and in accordance with local requirements.
- If a fire occurs, do not use water for extinguishing it. Never clean the product with high pressure or running water.
- Do not immerse the product in water or other liquids.
- It is advisable to have extra protection around the post when mounted in an open parking space.
- Make sure that children do not play with the product.
- Do not use extension cords or unapproved adapters in combination with the product.
- Even if the Charging Robot is designed to withstand normal weather conditions, we recommend protecting it from direct sunlight or exposure to extreme weather conditions.
- Do not use the product near strong electromagnetic fields or in the direct vicinity of radio transmitters.
Product overview
Common parts
1-Way/2-Way
Screws| |
---|---|---
1-Way| x3| x7
2-Way| x6| x8
Assembly instructions
Column Adapter plate
Attach the foundation of the column to the adapter plate with 4 socket head
screws. Recommended torque is 30-40 Nm.
INFO! It can be mounted in 45° increments to get the correct direction.
1-Way
1
Plate and cover
Attach the mounting plate with 3 flat head screws and the cover with 3
rounded head screws.
NOTICE! Make sure the top end of the column is sealed with a plastic cap.
2
Backplate
Thread the cable through the hole in the column and the Easee charger
backplate before attaching it with 4 rounded head screws.
2-Way
1
Plates
Attach the mounting plates to the column with 3 flat head screws each (6
screws total).
NOTICE! Make sure the top end of the column is sealed with a plastic cap.
2
Backplates
Thread the cables through each hole in the column and the Easee chargers
backplates before attaching them with 4 rounded head screws (8 screws total).
Power Rail
Before connecting
The Power Rail is a connection box that allows multiple charging ports to be
connected in series.
Please pay attention to the earthing system of the charging port, which is
described carefully in the following pages.
| WARNING! The Power Rail is a product to be installed by an authorized
electrician, and a declaration of conformity must always be provided upon
completion by your installer.
---|---
| WARNING! Turn off the power before beginning the wiring. Use extreme
caution and follow instructions carefully.
1
Ground connection plate
Before installing the Power Rail make sure to apply for the ground connection plate. The plate is essential for connecting the post to the protective earth (PE).
-
Make sure the top PE terminal screw is open, then wedge the end of the plate into the terminal from the back. The ground connection plate should lie
flat to the plastic housing. -
Insert the serrated washer on the rod inside the column. It should be placed between the metal column and the Power Rail.
-
Slide the Power Rail with the ground connection plate inside the column and latch the bottom of the rail into the catch.4. Fasten the grounding nut with the spring washer on the rod.
NOTICE! In order to complete the PE connection, the grounding nut has to be fastened and the top PE terminal screw has to be tightened (regardless of whether there is a wire in it or not).
Important! Do not forget this step!
2
Terminals
The ground connection plate connects the entire leftmost lane to the metal
column, so it is very important that this lane is only used for PE
connections.
We recommend using the two lower terminal sets for the main power cables.
One set of terminals is used for power in and the other is used for power out
if you want to connect another charging post on the same cable. Wire size up
to 25mm² ALU and CU.
We recommend using the two upper terminal sets for the charger cables.
For a single charger, only one set of terminals is used, and for two chargers,
both sets of terminals are used.
Wire size up to 6mm².
3
Wiring
- Strip the individual wires by 12 mm. If the cable has flexible conductors, it is recommended to use ferrules on stranded wires. Use the correct tools to press them.
- Tighten the screw terminal with a torque of 5 Nm.
NOTICE! When connecting multiple backplates in parallel, each screw
terminal serves as a coupling point for adjacent backplates. All backplates
must be
connected with the same phase sequence. External junction boxes or flat cables
can be used if it is more convenient.
NOTICE! It’s recommended to follow the existing color codes used in the
installation. Depending on national standards, the colors of the cables can
vary from the illustrations. The illustrations in this manual follow the IEC
60446 standard.
NOTICE! Before turning on the power, make sure the wires are properly
connected and tightened. Test this by pulling on each wire.
TN/TT 3-phase
(230/400 V)| IT/TT 3-phase
(230 V)
---|---
TN 1-phase
(230 V)| IT/TT 1-phase
(230 V)
4
Side panel
After connecting all wires to the Power Rail, it is time to mount the side
panel with the 4 rounded head screws.
Practical details
Warranty
The device is free from material defects and is in accordance with laws and
regulations for consumer protection in the country where the product is
purchased or where the consumer lives. All correctly installed Easee hardware
is covered by our 3 years limited warranty.
Some countries may have extended warranty.
Foundation
This charging post usually needs a mechanical foundation to be installed. The
adapter plate is compatible with most c/c 160 mm foundations.
In some situations, it is also possible to use the smaller base of the column
directly without the adapter plate, in this case using a 80 x 80 center to the
center footprint.
Screws
For all the flat and rounded head screws we recommend 7-9 Nm of torque.
Returns and complaints
Contact your distributor or Easee Customer Support regarding the return and
complaint of your product.
Customer support
Download the latest manuals, find answers to frequently asked questions, and
useful documents and videos for your product at
easee.support.
THIS DOCUMENT CONTAINS INFORMATION THAT IS SUBJECT TO CHANGE WITHOUT NOTICE.
The latest version of this publication can be downloaded at
http://easee.support
No part of this publication may be reproduced or transmitted in any form or by
any means, electronic or mechanical, including, but not limited to, copying,
recording, retrieving data, or computer networks without the written
permission of Easee AS.
Easee and all other Easee product names and slogans are trademarks or
registered trademarks of Easee AS.
Easee products can be protected by one or more patents.
All other products and services mentioned may be trademarks or service marks
of their respective owners.
Illustrations of the product and user interface are exemplary and may differ
from the actual appearance.
April 2022 – Version 3.00
© 2020 by Easee AS. All rights reserved.
Contact details
Easee AS
Grenseveien 19
4313 Sandnes, Norway
Org. nr: 920 292 046
You can find additional contact details for your country at
easee.com.
Easee AS
Grenseveien 19
4313 Sandnes, Norway
www.easee.com