Introduction

Easy Base
The Easee Base is a modular charging post for mounting up to four Easee Charging Robots.
With Ease Base, it is possible to choose between four different configurations. A one-way setup where only one charger is mounted, a 2-way setup with two chargers, a 3-way setup with three chargers, and finally a 4-way setup where there is a charger on all sides of the post.
With four configurations in one design, they share many common parts. Only a few parts are specific to each type of layout.

Conventions

This symbol indicates that the respective instructions must only be carried out by an authorized electrician.
This symbol indicates an immediate danger to the life and health of individuals due to the effects of electrical energy. Non-observance of these instructions will result in serious damage to health – up to and including life-threatening injuries.

Technical specifications

General
Dimension (mm): H: 1500 x W: 156 x D: 80
Weight: 6.1–7.7 kg
Material: Aluminium
Finish: Powder coating
Colour: Black
IP degree: IP44
Features
Adapter plate for c/c 160 mm foundation 45-degree rotation intervals (using the adapter plate)
Screws and nuts included
Electrical connection
Connection via Power Rail
Possibility of the serial connection of posts
Cable size
In and out of the post: Max 25 mm²
Up to the chargers: 6 mm²
Cable length (between chargers and Power Rail): 135 cm

Safety instructions

Read the entire manual carefully before installing and operating the product. Observe the following instructions:
Safety instructions for the installation

  • This product shall only be installed, repaired, or serviced by an authorized electrician. All applicable local, regional and national regulations for electrical installations must be respected.
  • Danger to life due to high electrical voltage. Never make any changes to components or connecting cables.
  • The installation must not be carried out in the vicinity of explosive atmospheres or in areas where there is a risk of flowing water.
  • The product must be installed in a permanent location.
  • The terminals in the backplate are energized when the power circuit is closed and must never be in direct contact or in contact with anything other than the plug-in electronics (Chargeberry).
  • Depending on the type of installation, official authorizations may be required prior to installation.

Safety instructions for operation

  • Danger to life due to high electrical voltage. Never make any changes to components or connecting cables.
  • Always have the prescribed maintenance, installation, and repair work carried out by an authorized electrician and in accordance with local requirements.
  • If a fire occurs, do not use water for extinguishing. Never clean the product with high pressure or running water.
  • Do not immerse the product in water or other liquids.
  • It is advisable to have extra protection around the post when mounted in an open parking space.
  • Make sure that children do not play with the product.
  • Do not use extension cords or unapproved adapters in combination with the product.
  • Even if the Charging Robot is designed to withstand normal weather conditions, we recommend protecting it from direct sunlight or exposure to extreme weather conditions.
  • Do not use the product near strong electromagnetic fields or in the direct vicinity of radio transmitters.

Common parts

easee BPR1W001 Base Charging Pedestal PR 1-Way - Common
parts

Common parts

Adapter plate

Attach the foundation of the column to the adapter plate with 4 socket head screws. Recommended torque is 30-40 Nm.
INFO! It can be mounted in 45° increments to get the correct direction.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig1

1-Way

easee BPR1W001 Base Charging Pedestal PR 1-Way -

1-Way

Parts

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig2

1-Way

Plate and cover

Attach the mounting plate with 3 flat head screws and the blind cover with 3 rounded head screws.
NOTICE! Make sure the top end of the column is sealed with a plastic cap.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig3

1-Way

Backplate

Thread the cable through the hole in the column and the Easee charger backplate before attaching it with 4 rounded head screws.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig4

2-Way

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig5

2-Way
Parts

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig6

2-Way
Plates
Attach the mounting plates to the column with 3 flat head screws each (6 screws total).
NOTICE! Make sure the top end of the column is sealed with a plastic cap.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig7

2-Way

Backplates

Thread the cables through each hole in the column and the Easee chargers backplates before attaching them with 4 rounded head screws (8 screws total).

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig8

3-Way / 4-Way

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig9

3-Way / 4-Way
Parts

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig10

3-Way / 4-Way

Bottom frame

Slide the bottom frame over the column and fasten it to the lower threaded hole with 1 rounded head screw on each side (2 screws total).

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig11

3-Way / 4-Way

 Top frame

Attach the top frame to the top two threads using 2 rounded head screws on each side of the column (4 screws in total).

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig12

3-Way / 4-Way
Top plate
Cover the top frame with the top plate and fix it with 4 rounded head screws.
NOTICE! Make sure that all cables are pulled through the column holes (2 on each side) before attaching the charger’s backplates.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig13

3-Way / 4-Way
First 2 chargers
Now attach the first 2 Ease chargers backplates to the sides perpendicular to the column openings with 4 rounded head screws each (8 screws total).
NOTICE! Pull the cable through the hole in the backplates before attaching them.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig14

3-Way

Last charger and cover

If you are installing a 3-way setup, attach the last backplate to one of the open sides and close the other side with the blind cover.
Before attaching the blind cover, the shielding tab must be flipped up in order to mount the blind cover plate, with 4 rounded head screws.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig15

4-Way
Last 2 chargers
If you are installing a 4-way setup, attach the last 2 Easee chargers backplates to the column with 4 rounded head screws each (8 screws total).
NOTICE! Before installing the electronics in the backplates, they must all be programmed – please check the installation guide that came with the Charging Robots.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig16

Power Rail

Before connecting

The Power Rail is a connection box that allows multiple charging ports to be connected in series.
Please pay attention to the earthing system of the charging port, which is described carefully in the following pages.
WARNING! The Power Rail is a product to be installed by an authorized electrician, and a declaration of conformity must always be provided upon completion by your installer.
WARNING! Turn off the power before beginning the wiring. Use extreme caution and follow instructions carefully.

Ground connection plate

Before installing the Power Rail make sure to apply for the ground connection plate. The plate is essential for connecting the post to the protective earth (PE).

  1. Make sure the top PE terminal screw is open, then wedge the end of the plate into the terminal from the back. The ground connection plate should lie flat on the plastic housing.easee BPR1W001 Base Charging Pedestal PR 1-Way - fig18

  2. Insert the serrated washer on the rod inside the column. It should be placed between the metal column and the Power Rail.

  3. Slide the Power Rail with the ground connection plate inside the column and latch the bottom of the rail into the catch.
    easee BPR1W001 Base Charging Pedestal PR 1-Way - fig19

  4. Fasten the grounding nut with the spring washer on the rod.
    NOTICE! In order to complete the PE connection, the grounding nut has to be fastened and the top PE terminal screw has to be tightened (regardless of whether there is a wire in it or not).
    Important! Do not forget this step!
    easee BPR1W001 Base Charging Pedestal PR 1-Way - fig20

Terminals

The ground connection plate connects the entire leftmost lane to the metal column, so it is very important that this lane is only used for PE connections.
We recommend using the two lower terminal sets for the main power cables.
One set of terminals is used for power in and the other is used for power out if you want to connect another charging post on the same cable. Wire size up to 25mm².

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig21

We recommend using the two upper terminal sets for the charger cables.
For a single charger, only one set of terminals is used, for two chargers, both sets of terminals are used, and for three or four chargers, two wires have to share a terminal. Wire size up to 6mm².
easee BPR1W001 Base Charging Pedestal PR 1-Way - fig22

Power Rail
Wiring
The Power Rail has 5 lanes. This allows support for TN, IT, and TT three and one-phase electrical grids.

  1. Strip the cable cores by 12 mm. If the cable has flexible conductors, it is recommended to use cable end sleeves on all wires. Use the correct tools to press them.
  2. Tighten the screws with a torque of 5 Nm.
    NOTICE! Terminations should be visually and mechanically inspected before mounting the side panel.

TN 3 phase

**TN 1 phase

**

**IT/TT 3 phase

**

**IT/TT 1 phase

**

TN network
TN is the most common grid type in Europe. It uses five conductors to provide both 230 V and 400 V. This makes it very efficient and thus the preferred grid type for charging electric vehicles.
IT/TT network
IT and TT grid systems are mostly used in Norway and Albania but occur in Belgium, France, and Spain too.
These systems have no neutral connector and use 4 conductors only. They can thus only provide 230 V.
NOTICE! It’s recommended to follow the existing color codes used in the installation. Depending on national standards, the colors of the cables can vary from the illustrations. The illustrations in this manual follow the IEC 60446 standard.
NOTICE! Make sure the conductors are properly connected before turning on the power for the Charging Robot(s).

4 Side panel
After connecting all wires to the Power Rail, it is time to mount the side panel with the 4 rounded head screws.

easee BPR1W001 Base Charging Pedestal PR 1-Way - fig28

Practical details

Warranty
The device is free from material defects and is in accordance with laws and regulations for consumer protection in the country where the product is purchased or where the consumer lives. All correctly installed Easee hardware is covered by our 3 years limited warranty.
Foundation
This charging post usually needs a mechanical foundation to be installed. The adapter plate is compatible with most c/c 160 mm foundations. We recommend foundations similar to Ørstafundament.
In some situations, it is also possible to use the smaller base of the column directly without the adapter plate, in this case using an 80 x 80 center-to- center footprint.
Screws
For all the flat and rounded head screws we recommend 7-9 Nm of torque.
Returns and complaints
Contact your distributor or Easee Customer Support regarding the return and complaint of your product.
Customer support
Download the latest manuals, find answers to frequently asked questions, and useful documents and videos for your product with ease. support.

Contact details
Easee AS
Grenseveien 19
4313 Sandnes, Norway
Org. nr: 920 292 046
You can find additional contact details for your country at easee.com.

THIS DOCUMENT CONTAINS INFORMATION THAT IS SUBJECT TO CHANGE WITHOUT NOTICE.
The latest version of this publication can be downloaded at http://easee.support
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including, but not limited to, copying, recording, retrieving data, or computer networks without the written permission of Easee AS.
Easy and all other Easee product names and slogans are trademarks or registered trademarks of Easee AS.
Easy products can be protected by one or more patents.
All other products and services mentioned may be trademarks or service marks of their respective owners.
Illustrations of the product and user interface are exemplary and may differ from the actual appearance.

 Version 2.00
© 2020 by Easee AS. All rights reserved.

Easee AS
Grenseveien 19
4313 Sandnes, Norway
www.easee.com

Documents / Resources

| easee BPR1W001 Base Charging Pedestal PR 1-Way [pdf] Installation Guide
BPR1W001 Base Charging Pedestal PR 1-Way, BPR1W001, Base Charging Pedestal PR 1-Way, Pedestal PR 1-Way
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals