Read before installation and use of the product carefully these instructions. Keep them for later use on. If you give the product, give please continue this guide

Preliminary remark

Intended Use

This product was designed as a measuring device designed in conjunction with a Easee Equalizer the energy use in buildings optimized. It enables one automatic load balancing between the Easee charging robot(s) and the Building if no smart meter was installed.

Operating conditions

The product must have the supplied Cable connected to an Easee Equalizer will. For installation and operation a smartphone with an internet connection needed.

Optimal performance

The equalizer amp allows in connection with the Easee Equalizer a smarter, safer and faster charging even without intelligent meter/smart meter when the installation is scaled accordingly.

Product overview

  1. Equalizer amp
  2. Power cord
  3. Current sensors
  4. DIN mount
  5. Expansion connector

Safety instructions

Read carefully the entire manual, before you install the product and in operation. Note the following

Hints:

  • Do not use the product if it is damaged or incorrect functions.
  • Always leave repair work to you an authorized electrician and in accordance with local execute policies.
  • This product is only for them Use in dry indoor areas intended. Will it be outside of the house installed, it must be in a weatherproof housing to be accommodated
  • Do not immerse the device in water or other liquids.
  • Avoid direct sunlight and exposure to heat.
  • Keep the device away from open flames and away from extreme heat.
  • Make sure that children do not use the play device.

Technical specifications

Generally

  • Dimensions (HxWxD): 95x51x30 mm
  • Temperature range : -20°C to +50°C
  • Weight : 105g
  • Supply voltage : 85-264VAC
  • Network type : TT, IT or TN
  • Phases: 1 or 3 phase

Current sensors

  • Type: CT Clamps
  • Application range: 0 – 100 A
  • Cable diameter: max 16mm
  • Cable Length : 1.5m

Protection

  • Protection class: IP30
  • Insulation class : II
  • Overvoltage category: OVC II

Connection

  • 2 x RJ12
  • 6x sensor slots
  • 1x 12 pin extension connector

Installation instructions

WARNING! This product may only by one installed by an authorized electrician be repaired or serviced. All applicable local, regional and national regulations for electrical installations must get noticed.
WARNING! Switch the power off before you start the installation start Be extremely careful and follow them carefully Instructions.

Install the installer app on your smartphone by going to easee.com/installerapp visit or the QR code shown scan

Mount

Mount the equalizer amp on the DIN rail (A) in the fuse box.If that is not possible, screw the DIN bracket (B) to a secure one surface and then mount the equalizer amp

Fasten

  • Reattach the current sensor(s). each ladder, either in front of or behind the main fuse. The arrow on the sensor must point in the direction of the load.
  • Plug in the current sensors L1, L2 and L3 into their respective terminals 1, 2 and 3 a. Terminals 4, 5 and 6 serve as additional slots.

NOTICE! Depending on national Standards may change the color of the cable from this Deviate from illustrationeasee-Equalizer-Amp-fig-
\(5\)

Connect

  1. Plug in the included power cord to a suitable power source. Of the Installation of a separate fuse with a maximum rating of 16 A is recommended.
  2. Connect the RJ12 cable of the equalizer Box with an RJ12 connector on Equalizer Amp. The bottom RJ12 connector is for connecting to multiple Equalizer amp provided TEST! Make sure before Switching on the equalizer amp that: Ѐ the direction of the current sensors correct is. Ѐ the charging points and the equalizer amp have the same phase sequence. Ѐ the L1 current sensor in terminal 1, the L2 sensor in terminal 2 and the L3 sensor in Plugged in terminal 3 of the Equalizer Amp would.
  3. Turn on the Equalizer Amp. You should see a blinkingeasee-Equalizer-Amp-fig- \(6\)

Furnish

  • Use the Easee Installer app to install the Equalizer in one site with several set up circuits.
  • Make sure the equalizer and the Master charging robot with the same WiFi network are connected. place also Make sure NFC is on your mobile phone is activated.
  1. Go to Current Locations or Update existing location and select the location.
  2. Under Location Structure, select the Add equalizer option.
  3. Enter the WiFi access data (the same network that the charging robots are connected).
  4. Hold the mobile phone to the front of the equalizer to display the WiFi data transferred to. The equalizer can Information not received when he is switched on.
  5. Connect the equalizer with the RJ12 cable to the equalizer ampeasee-Equalizer-Amp-fig- \(7\)

Practical details

  • Meaning of LED colors
  • White Fast Flashing – Starting
  • White flashing every 10s – Normal operation
  • Red / white alternating – no WiFi added
  • Red, flashing – no data from power meter
  • Red flashing every 10s – error
  • Purple, flashes every 10s – offline operation

Guarantee

The device is free from material defects and complies with laws and regulations to the consumer protection of the country in which the product was purchased.

Standards

Easee AS hereby declares that the equalizer Amp of the Low Voltage Directive 2014/34/ EU, the EMC Directive 2014/30/EU and the Complies with RoHS Directive 2011/65/EU.
The full text of the EU declaration of conformity is under the following Web address available: easee.support

Maintenance

This product requires no maintenance.
Should a repair become necessary, please contact your Easee supplier.

Storage

  • The product should be stored in a tempered, dry and well-ventilated area be stored to the packaging and protect their content. the relative humidity should be 80% not exceed and there should be none corrosive gases may be present. The camp and
  • Transport conditions should the indicated in the technical data
  • Do not exceed limits.

Disposal

  • The crossed-out garbage can shows Consumers who do not have devices in the household waste may be disposed of. For the Return of old devices can be free of charge
  • Collection and acceptance points used will. Observe the local regulations to the correct and environmentally friendly Disposal.

Returns and Complaints

Regarding return and complaint of yourproduct, contact your retailer or Easee Customer Service at easee.support.

THIS DOCUMENT CONTAINS INFORMATION THAT IS SUBJECT TO CHANGE WITHOUT NOTICE.

  • The latest version of this publication can be downloaded at http://easee.support
  • No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including, but not limited to, copying, recording, retrieving data, or computer networks without the written permission of Easee AS.
  • Easee and all other Easee product names and slogans are trademarks or registered trademarks of Easee AS. Easee products can be protected by one or more patents.
  • All other products and services mentioned may be trademarks or service marks of their respective owners.
  • Illustrations of the product and user interface are exemplary and may differ from the actual appearance.
  • November 2022 – Version 1.00 © 2022 by Easee AS. All rights reserved

Contact details
Easee AS Grenseveien 19 4313 Sandnes, Norway
Org. nr : 920 292 046
You can find additional contact details for your country at easee.com.
Easee AS Grenseveien 19 4313 Sandnes, Norway

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals