NOYAFA NF-8509 Wire Tracker With Multimeter
Product Introduction
NF-8509 multifunctional digital multimeter and wire tracer is designed with cable testing function and multimeter function.
- Network cable testing functions: cable length test,wire continuity test, wire scanning test, POE test, and Port flash.
- Digital Multimeter (DMM) functions: AC/DC voltage test, continuity test, diode test, temperature test, NCV test, resistance test, AC /DC current test.
Note: Wire scanning is enabled by default after turn on the device.
Operating instructions of cable testing functionality
-
Wire scanning: In wire scanning mode, press “ ” button, the screen shows “1” indicating digital wire scanning mode. Press “ ” button again, the screen shows “2” indicating analog wire scanning mode.
Note: maximum wire scanning distance: < 600 meters under no load; < 1, 000 meters under load. -
Wire mapping: Press button to enable wire mapping function, then press “ ” button to perform wire mapping test (up to 2,000 meters).
-
Port flashing: Press “ ” button to enable port flashing function, then press “ ” button to perform port flashing detection (10M/100M/1,000M identification).
-
Length test function: press “ ” button to enable length test function, then press “ ” button to perform length test (range: 5-200 meters).
-
POE function: Press “ ” button to enable POE function, and the device will automatically detect the POE voltage.
Operating instructions of multimeter functionality
After power-on, press “ ” to enter the multimeter function mode. Press “ ” button again to switch among AC voltage, DC voltage, diode/continuity, NCV, resistance, DC/AC current, frequency, and ambient temperature tests. After selecting the desired function, press “ ” button to start testing. The device defaults to AC voltage test.
- AC/DC voltage measurement: 600mV-61 0V.
- Continuity test: to detect the connectivity performance of wires and various conductors (the buzzer will sound when resistance is below 500).
- Diode measurement: to identify the polarity and forward voltage drop of diodes (0-3.3V).
- NCV function: AC signals can be detected when the device is close to the AC signal source (0-4 levels).
- Resistance measurement: 600O-60MQ.
- AC/DC measurement range: 1 mA-3A DC (accuracy: ±0.8%+3).
- Frequency: 0-10MHz (accuracy: ±1.0%+3).
- Others: to display the ambient temperature.
Battery level indication
- Transmitter: 0% indicate low battery level, please recharge ii in time.
- Receiver: Power indicator flashes, indicating low battery level, please replace it in time.
Packing List
Emitter | 1pc | Type-C USB | 1pc |
---|---|---|---|
Receiver | 1pc | Cable adaptor | 1pc |
User manual | 1pc | Earphone | 1pc |
Carry bag | 1pc | Multimeter pen | 2pc |
Product Parameters
Model | NF-8509 |
---|---|
Auto-off | ✓ |
Transmitter | Wire mapping test |
Wire scanning | RJ45 600m |
Wire length test | 5-200m (±3m) |
Port flashing test | 10M/100M/1,000M |
POE | 4-core/8-core power supply detection |
POE voltage detection
Continuity test| Detect The connectivity performance of wires and various
conductors, The buzzer will sound when resistance is below 500.
Identify the polarity and forward voltage drop of diodes (0-3.3V)
NCV function| Inductive voltage detector (0-4 levels)
Resistance measurement| 600O-60MO (accuracy: ±1.0%+5)
AC/DC voltage measurement| 600mV-61 0V (DC accuracy: ±0.5%+3; AC accuracy:
±0.5%+3)
AC/DC measurement| 1mA-3A DC (accuracy: ±0.8%+3)
Frequency| 0-l0MHz (accuracy: ±1.0%+3)
Power| 3.7V/1,500mA lithium battery
Ambient temperature display| ✓
Dimensions| 137.5X76X34mm
Receiver| LED light| ✓
Telephone function| ✓
Power| DC9V (exclusive)
Maximum working current| <150mA
Dimensions| 204.9X38X29mm