M2000C 2nd Generation
Multi-functional
Air Quality Detector User Manual
Factors Affecting Air Quality
| PM2.5 (Particulate Matter 2.5) refers to fine particles with a diameter of
2.5 micrometers or less. Due to its tiny size, PM2.5 can be absorbed into
bloodstream and the lungs, so that long-term exposure to high concentration of
PM2.5 environment may cause eye and nose irritation, cough, asthma, emphysema,
lung disease, heart attacks, cancer and etc.
---|---
| PM10 (Particulate
Matter 10) refers to particles with a diameter of 10 micrometers or less. Due
to the larger size, it’s inhalable but penetrates no further than bronchi as
larger particles can be filtered out by cilia and mucus of nose and throat. It
is normally considered as less harmful to health than PM2.5.
| CO2 (Carbon dioxide) is a colorless and odorless gas that is usually derived
from the breath of humans and animals. High CO2 concentration means that fresh
air or ventilation is required, otherwise it may cause problems such as
drowsiness, dizziness, loss of attention, and cognitive impairment.
Important!
- Do not place the detector in highly polluted environments (concentration of CO2>2500ppm or particle>500pg/m3) for a long time to avoid damage to the sensor.
- Do not cover the air inlet/outlet during detection, or let fluff or hair enter the detector.
- Do not use the detector in humid environments with a strong odor.
- Do not make contact with organic solvents, such as glue/adhesives/paint/alcohol, etc.
- If the battery level shows 0, please charge the detector promptly to avoid effects during use (also chargeable when turned off).
Overview
- Buzzer Status
- Measuring Status
- Display
- Menu Button
- Increase/Up Button
- USB Port
- Date & Time
- Power Level
- Back Button
- Power/OK Button
- Decrease/Down/Switch (Start/Pause) Button
Operation
Warning!
- First use or unused for a long time: Please put it outside for over 6 hours for calibration.
- Indoor use: Keep the room/area airtight for 10 minutes to obtain more accurate results.
- When calibrating the CO2 sensors, please adjust the detector to the calibration interface and place it outdoors in a cool and ventilated place for 3o minutes. Detection results will be much more accurate.
-
ON
Press and hold for 2 seconds to turn on the detector. -
Detection
Press to enter the main menu interface (see the figure below), then press or to locate the option to view or set and press to confirm.
Note: It takes about 3 minutes for the CO2 sensor to warm up and then enter detection status.
View or Set PM2.5/CO2
In each interface, press to display more functions. Take the CO2 interface,
for example, press button, and you may see the following function options:
a. Pause
measuring: Pause or restart detecting CO2.
b. Turn on alarm sound: Mute / Unmute the buzzer.
c. Display the data: Display (or not) the CO2 concentration curve.
d. Alarm value setting: Set a high alarm limit.
Operation: Press or button to adjust the value and press to switch
digits. Then press Save to save the setting and exit the interface, or press
Exit to exit without saving the setting (See the figure below).
e.
Calibration zero: Calibrate the sensor to zero (no such function for PM2.5
interface). Take CO2 interface below for example:
f. EXIT:
Exit the current interface.
View all info
The View all info interface displays all the detected data including the
concentration of PM2.5, PM10, CO2, number of particles, temperature and
humidity. Press to switch between °C and °F. See the figures below.
Press to
pause or detect; press sr to back to the main menu interface.
History
The History interface includes Storage interval and Data export functions (See
the figure below).
Operation: Press or to switch between Storage interval and Data export,
then press to enter the corresponding interface.
a. Storage interval: Press: to switch between digits, Save and Exit. When
you select a digit, press or to adjust the value to your desired storage
interval among 1, 5, 10, 30, and 60 minutes, then locate the option to Save
and press to save the setting and exit the interface; or locate the option to
Exit and press to exit the interface without saving the setting.
b. Data
export: In this interface, you will see the following tips.
If
connected to the computer successfully by the USB cable, the detector will pop
up a tip USB connection successfully; If not, it will remind you of the
failure (See the figures below).
After
connecting successfully, the detector will generate in the computer a
removable storage device Temtop, which contains a folder named History. The
history folder includes a CSV format file listing the date and time, PM2.5,
PM10, and CO2 concentration (see the figure). Please save it to your computer
for viewing.
Date | PM2.5 | PM10 | Co2 |
---|---|---|---|
2019/10/28 15:5 | 6 | 10 | 2038 |
2019/10/28 15:10 | 7 | 11 | 1795 |
2019/10/28 15:15 | 8 | 14 | 1914 |
After the data is copied and viewed, please press to exit and restart the
detector (See the figure below).
Set
The Set interface displays 5 options below. Operation: Press or to select the
desired option; press to enter the interface.
a. Date
and time: Allows customized setting of year, month, date, and time (See the
figure below).
Operation: Press or to adjust time and press to switch to the next digit.
Then press to switch to Save or Exit. Press to finish the settings and exit
the interface.
b. Alarm
value: Set a high alarm limit for PM2.S, or CO2 concentration (See the
figure below).
Operation: Press or set a high alarm limit for PM2.S, or CO2
concentration, and press to switch to the next digit. Then press to switch to
Save or Exit. Press to finishes the settings and exit the interface.
c. Help: View the help information for using the detector (See the figure
below).
Operation: Press or to view the information that helps you use the
detector; press back to Set interface.
d.
Restore: Reset to the default parameters (See the figure below).
Operation: Press to switch to Restore or Exit. Press to confirm the
settings and exit the interface. If reset, all the customized settings will
automatically turn to the default.
e. Language: Set Chinese or English as a displayed language (See the figure
below).
Operation: Press to switch between Chinese and English, press to confirm; then
press again to switch to Save or Exit; press to finish the settings and exit.
3. Multipoint Detection Repeat 2 Detection at multiple points in the
targeted area to get a more comprehensive understanding of your air quality.
4. OFF Under normal operating status, press and hold for 2 seconds to
turn off the detector. It will be auto-off after 1 hour of inactivity.
Note: The auto-off function is invalid in the Histogram interface.
Specifications
Model | M2000C 2nd |
---|---|
Dimensions | 223.5×73.5×37.5mm / 8.8×2.8×1.4in. |
Battery capacity | 3000mAh |
Battery life | 6-8h |
Input | DC5V; 1A |
Display | TFT color screen |
Operation environment | Temperature range: 0-50°C (32-122°F) Humidity range: |
0-90% RH
Atmospheric pressure condition: 1 atm
PM2.5| Sensor: Laser PM sensor
Measuring range: 0-999 pg/m3 Resolution: 01 pg/m3
Accuracy: ±10 pg/m3(0-100 pg/m3) ±10%(100-500 pg/m3)
PM10| Sensor: Laser PM sensor
Measuring range: 0-999 pg/m3 Resolution: 01 pg/m’
Accuracy: ±15 pg/m3(0-100 pg/m’) ±15%(100-500 pg/m3)
Carbon dioxide (CO2)| Sensor: Non-Dispersive Infrared (NDIR) CO2 sensor
Measuring range: 0-5000 ppm
Resolution: 1 ppm
Accuracy: ±(50 ppm + 5% reading)
FAQ:
Q: Why is the data reading very high/over-range after the detector is
turned ON?
A: As being packed in ink printed package box over time may interfere with the
sensor due to the remaining organic volatile residue inside the package.
Therefore, after unpacking, please put the detector in a ventilated place to
help accelerate its data recovery.
Q: Why is data reading unstable?
A: As airflow in the environment is changing, the distribution of organic
matter concentration may be uneven. Temp recommends trying again in low
airflow areas.
Q: Why is the test result abnormal or below normal?
A: (1) Please check whether the air inlet or outlet has been covered or fluid
is in.
(2) Gently shake the detector during detection to increase the interaction
with the surrounding air.
(3) The sensor maybe not have recovered. Please place the detector outdoors
for ventilation.
Q: Can the calibration be accelerated if the detector is facing the outlet
of air conditioner/fan?
A: No. The temperature difference or airflow speed at the air conditioner/fan
outlet is relatively high, which may cause condensation or temperature changes
on the sensor, affecting its detection performance. Please put the detector
outdoors in a cool ventilated place.
Q: Why is the PM2.5 reading constantly changing?
A: As PM2.5 concentration in the environment is changing all the time not only
due to environmental factors like changes in airflow, humidity, wind direction
and etc. but also due to common pollutant sources like smoking, cooking;
exhaust emissions from vehicles, smoke from burning coal/chimneys/furnaces and
etc. All of these may influence the PM2.5 concentrations and give differences
in the readings.
Q: Which reference standards have been used to indicate the pollution
levels?
A: Reference Standards for Particles and CO: are shown below.
Status/ Pollutant| Good| Moderate| Unhealthy
for Sensitive
Groups| Unhealthy| Very
Unhealthy| Hazardous
---|---|---|---|---|---|---
PM2.5
(pg/m3)| ≤12| 12.1∼35.4| 35.5∼55.4| 55.5∼150.4| 150.5∼250.4| ≥250S
PM10
(Pg/m3)| ≤54| 54.1∼154| 154.1∼255| 255.1∼354| 354.1∼424| ≥425
CO2
(ppm)| ≤700| 701∼1000| 1001∼1500| 1501∼2500| 2501∼5000| ≥5001
What’s Included
Detector x1
USB Cable x1
User Manual x1
Warranty
Temp warrants the included item for1 a year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage. )
Item | Warranty Period | Service Mode |
---|---|---|
Detector | 1 year | Send to us |
Accessories | N/A | N/A |
Before returning or sending for repair, please check if the following items are ready:
| Detector & **Accessories| Complete Package| Proof of
Purchase*| Gift (if any)
---|---|---|---|---
Return| V| V| V| V
Exchange| V| V| V|
Repair| V| | V**|
-
Including invoice, order number, etc.
Temp warranty does NOT include- Malfunction or damages caused by artificial damage or modification
- Other deliberate damages.
- Damages caused by force majeure events.
Elltech Technology, Inc.
2528 Qume Dr, Ste 2
San Jose, CA 95131 USA
Tel: +1408-898-2866
Sales: sales@temtopus.com
Website: www.temtopus.com
Elitech (UK) Limited
Unit 13, Greenwich Centre Business Park
53 Norman Road, London, SE10 9QF UK
Tel: +44 (0)208-858-1888
Sales: sales@elitech.uk.com
Website: www.elitecheu.com
Elitech Brasil Ltda
R. Dona Rosalina, 90 – Igara, Canoas – RS,
92410-695, Brazil
Tel: +55 (51)-3939-8634
Sales: brasil@e-elitech.com
Website: www.elitechbrasil.com.br
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>