Temtop S1 Air Quality Monitor Indoor Thermometer User Manual

May 15, 2024
Temtop

S1 Air Quality Monitor Indoor Thermometer
User Manual S1 Air Meter

Factors Affecting Air Quality

PM2.5 (Particulate Matter 2.5) refers to fine particles with diameter of 2.5 micrometers or less. Due to its tiny size, PM2.5 can be absorbed into bloodstream and the lungs, which may cause eye and nose irritation, cough, asthma,  emphysema, lung disease, heart attacks, cancer and etc.
Temperature & Humidity may often be ignored however they do have a significant impact on individual’s well-being , comfort, health and safety as well as your property. High humidity may lead to an increase in household air pollutants
especially the biological contaminants such as molds, bacteria, viruses and dust mites; cold, low humidity may cause nosebleeds, skin and respiratory irritations, dyspnea, static electricity and etc.
AQI (Air Quality Index) is a quick guide showing how clean or polluted the air is, using a range from Oto 500, where higher index values indicate higher levels of air pollution and higher risks to health. There are six pollutants for AQI in  US standard: PM2.5/10, 03, S02, N02, CO, where Temtop only focus on PM2.5/10 and follows the US EPA Standards to compute AQI.

Important

  • Do not place detector in heavily polluted environments for a long time; or it may cause damages to the sensor.
  • Do not use the detector in a humid environment for a long time to ensure the measurement accuracy.
  • Do not cover the vents of the detector, and do not let fluff enter the detector, otherwise the particle sensor may not work properly.
  • This product is only used to monitor the health of the indoor environment and cannot be used as a professional measurement tool.
  • Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.
  • Children should only use the device under adult supervision. Keep packaging material, like plastic bags and plastic film, out of the reach of children,as they pose a choking hazard.

Overview

Temtop S1 Air Quality Monitor Indoor Thermometer -
Overview

1 Work mode 2 PM2.5 & AQl level
4 Battery level & Charging status
6 Magnetic Back 7 Vents| 3 Temperature & Humidity level
5 Health level display area
8 Air inlet
---|---

Temtop S1 Air Quality Monitor Indoor Thermometer -
Overview1

9 Mode button 10 Power button 11 Air outlet 12 USB port 13) Temperature and humidity detection port 14 Bracket

Specifications

Model 51
PM2.5 Sensor: Laser PM sensor

Measuring range: 0-999 pg/m3 Resolution: 0.1 pg/m3
Accuracy: ±5 pg/m3 (0-50 pg/m3) ±10 pg/m3 (50-100 pg/m3)
±10% (100-500 pg/m3)
Temperature*| Measuring range: -10-60°C (14-140°F) Resolution: 0.1°C, Accuracy: ±0.5°C (±0.9°F)
Humidity| Measuring range: 0-99.9% RH Resolution: 0.1% RH, Accuracy: ±3% RH

  • When the product is charged, the temperature will have an error of ±0.5C, and it will recover in about 10 minutes after full change.
    When the temperature measurement environment suddenly changes, and the temperature difference is large, it may takes 3 to 5 minutes adaptation time.
Dimension 3.52.70.7 (inches)
Battery Capacity 800mAh
Work Mode* Power-saving Mode (30min)

A) Smart Mode (automatic)
Battery Life| 8 About 60 Days
0 About 20 Days
Input| SV/1A
Display| Segment code screen 3.3inches
Weight| About 110g
Operation Environment| -10-60°C/0-99.9%

  • When the product is charging, the data will keep refreshing every 1.5 seconds.
    Note: The above data are from Temtop Laboratory.

Operation

Waring!

  • Indoor use: Keep the room/area airtight for 10 minutes to obtain more accurate results.
  • If battery level shows , please charge the detector promptly to avoid effects during use (also chargeable when turned off).
  1. 0n/Off
    Press 3s to turn ON/OFF the 1 monitor,Temtop S1 Air Quality Monitor Indoor
Thermometer - 1 monitor

  2. Display
    1. The SThas two working modes, and you can switch the working mode by pressing the mode button after power on.Temtop S1 Air Quality Monitor Indoor
Thermometer - Display

A Smart mode
Embedded sensor automatic control lgorithm, taking into account the dynamic balance of data detection and product battery e, to provide users with a good experience!
Power-saving Mode (30min)

  1. PM2.5 Sensor works every 30 minutes;
  2. The temperature and humidity are still maintained for 105 to refresh.
    2. 51 monitoring function 1) When the battery is displayed as empty, please charge it in time, and the charging icon will be displayed when charging.
  3. When the battery power is extremely low, the battery icon will flash 3 times and then shut down.

Air Quality Parameter for Reference

Status Pollutant Green Yellow Red
PM2.5 (pg/m3) 0-12 12.1-55.4 >55.4
AQI* 0-50 51-150 >150
  • Refers to EPA standards, with PM2.5 as the main responsible pollutant.

Multiple Mounting Choices

Temtop S1 Air Quality Monitor Indoor Thermometer - Mounting
Choices

FAQ

Q: Why is the PM2.5 reading constantly changing?

A: As PM2.5 concentration in the environment is changing all the time not only due to environmental factors like changes in airflow, humidity, wind direction and etc. but also due to common pollutant sources like smoking, cooking; exhaust emissions from vehicles, smoke from burning coal/chimneys/furnaces and etc. All these may influence the PM2.5 concentrations and give dierences in the readings.

Q: Why is the test result abnormal ? ①

A: @) Please check whether the air inlet or outlet is covered or liquid has entered. (2) Gently shake the detector during detection to increase the interaction with surrounding air. (3) The sensor may be not recovered, Please place the detector outdoors for ventilation.

Q: Why data reading is unstable?

A: If the airflow in the current sampling space is in an unstable state, such as strong wind, the concentration of particulate matter in the air will be unevenly distributed, and will vary greatly with the surrounding airflow, resulting in large dierences in measured values.

Q: Why is the product data higher near the light source?

A: Our sensor uses the principle of light scattering, and the photosensitive element is close to the air inlet. If a strong light source is used to illuminate the position of the air inlet, it will interfere with the light signal and aect the data. Therefore, it is necessary to avoid direct glare from the air inlet.

Q: AQI/ PM2.5 and other values, why the measured value is inconsistent with the ocial announcement?

A: The AQI/PM2.5 shown on the display is a measurement of the space where the device is located. The measured value published on the Internet or ocial websites is the average value of several monitoring points, and each measurement point will be dierent. At the same time, according to the regulations of EPA and WHO, the AQI value is calculated based on the highest value among the five pollutants in the atmosphere on that day. In the past ten years, the local AQI in the United States has basically been calculated with the value of PM2.5/PM10, and sometimes with the value of O3.

What’s Included

  • Detector x 1
  • USB Cable x 1
  • User Manual x 1
  • Bracket or accessories set x1

Warranty

Temtop warrants the included detector for 1 year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage.

Item Warranty Period
Detector 1 year included
Accessories N/A

Before return or delivery for repair, please check if the following items are ready:

| Detector & Accessories| Complete Package| Proof of Purchase*| Gift (if any)
---|---|---|---|---
Return| √| √| √| √
Exchange| √| √| √|
Repair| √| | √|

*Including invoice, order number and etc.
Temtop warranty does NOT include:

  • Malfunction or damages caused by artificial damage or modification.
  • Other deliberate damages.
  • Damage caused by natural events.

Elitech Technology, Inc.
2528 Qume Dr, Ste 2
San Jose, CA 95131 USA
Tel: (+1) 408-898-2866
Sales: sales@temtopus.com
Website: www.temtopus.com
Elitech Brazil Ltda
R.Dona Rosalina,90-Lgara, Canoas-RS
92410-695,Brazil
Tel: (+55)51-3939-8634
Sales: brasil@e-elitech.com
Website: www.elitechbrasil.com.br
Elitech (UK) Limited
Unit 13 Greenwich Business Park,
53 Norman Road,London, SE10 9QF
Tel: (+44)208-858-1888
Support: service@elitech.uk.com
Website: www.temtop.co.uk
V1.0
Made in China

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)