sensepeek SP10 Passive 1:1 Handsfree Probe Kit User Guide
- July 17, 2024
- sensepeek
Table of Contents
sensepeek SP10 Passive 1:1 Handsfree Probe Kit
Product Information
The SP10 Passive 1:1 hands-free probe is designed for signal measurements and logic analyzers for high-speed serial communication interfaces such as SPI, CAN, USB, JTAG, I2C, UART, etc. It can also be used for resistance and voltage measurements, power, and grounding of devices with continuous currents of up to two amperes.
Specifications
- Product Name: SP10 – Passive 1:1 handsfree probe
- Manufacturer: Sensepeek AB
- Origin: Made in Sweden
- Address: Verkstadsgatan 2, Vellinge, Sweden
- Maximum Continuous Current: 2 Ampere
Product Usage Instructions
-
Warranty Information
The product comes with a 12-month warranty from the date of purchase covering defects in material and workmanship. However, it does not cover components subject to natural wear and tear. -
Disposal Instructions
Dispose of the product responsibly by returning it to Sensepeek for recycling. Alternatively, ensure WEEE-compliant collection and treatment. Do not dispose of the product as unsorted municipal waste. -
Safety Information
Read the safety information carefully before using the product to prevent any potential risks. Follow all safety practices related to working with electricity. -
Maximum Input Ranges
Ensure not to connect the probe to voltages exceeding the specified levels in the user guide to prevent electric shock. Be cautious when working with hazardous live voltages. -
Grounding Instructions
Avoid connecting the ground input to any electrical potential other than the ground to prevent personal injury. Always check for DC or AC voltage differences before connecting.
FAQ
Q: What is the maximum continuous current supported by the SP10 probe?
A: The SP10 probe supports a maximum continuous current of 2 Amperes.
Q: How long is the warranty period for Sensepeek products?
A: Sensepeek products are warranted for 12 months from the date of purchase.
Q: How should I dispose of the product when it reaches the end of its life?
A: You can return the product to Sensepeek for recycling or ensure WEEE- compliant collection and treatment.
Q: What safety precautions should I follow when using the SP10 probe?
A: Always read the safety information provided, follow general safety practices when working with electricity, and avoid connecting the ground input to any electrical potential other than the ground.
Introduction
This passive 1:1 probe is suitable for signal measurements and logic analyzers for high-speed serial communication interfaces like SPI, CAN, USB, JTAG, I2C, UART, etc. The probe can also be used for resistance and voltage measurements, power, and grounding of devices with continuous currents of a maximum of two amperes.
Warranty
Sensepeek products are warranted for 12 months from the date of purchase. The warranty covers defects in material and workmanship. This warranty does not apply to components (parts and accessories) subject to natural and normal wear and tear. This warranty does not in any way limit the rights you have under mandatory law.
Disposal
Sensepeek offers our customers the opportunity to return products at the
end of their functional lives to Sensepeek for recycling. Qualifying products
are marked with the WEEE symbol shown above. Or ensure WEEE-compliant
collection and treatment yourself. Do not dispose of this product as unsorted
municipal waste Delivery cost of any authorized product returned to Sensepeek
will be at the expense of the sender.
Safety
To prevent possible death, personal injury, electrical shock, fire, or damage
to the product, carefully read this safety information before using the
product. Follow all generally accepted safety practices and procedures for
working with and near electricity. The product has been designed by the IEC
61010‑031 standard and left the factory tested and in a safe condition.
- Safety descriptions found throughout this user guide: A WARNING identifies conditions or practices that could result in death or injury. To prevent injury or death only qualified personnel should use this product, only as instructed and with only accessories supplied or recommended. The protection provided by the product may be impaired if used in a manner not specified in this guide.
- CAUTION identifies conditions or practices that could result in damage to connected products or equipment.
Maximum input ranges
The full-scale measurement ranges are the maximum voltages that can be
accurately measured by the probe for safe operation. The overvoltage ranges
are the maximum voltages that will not damage the probe.
- WARNING To prevent electric shock, do not connect the probe to voltages exceeding the levels specified in this user guide, and do take all necessary safety precautions when working on equipment where hazardous live voltages may be present.
- WARNING Do not connect to a mains voltage or a derived voltage that can carry the overvoltage transients that may be present. Note that the probe’s maximum input voltage rating decreases as the frequency of the applied signal increases. This probe does not carry a measurement category rating.
Grounding
- WARNING Do not ever connect the ground input to, or allow it to touch, any electrical potential other than the ground. To prevent death or personal injury, always measure that there is no significant DC or AC voltage between the probe ground and the point to which you intend to connect it.
- CAUTION Applying a voltage to the ground input is likely to cause permanent damage to the probe or other connected equipment.
Environment
- WARNING To prevent death or injury, do not use near explosive vapor or gas.
- CAUTION To prevent damage to the probe, always operate and store your probe according to the levels specified in this guide.
Care of the product
The probe contains no user-serviceable parts.
- WARNING To prevent death or injury, do not try to open any part of the assembly, do not use the product if it appears to be damaged in any way, and stop use immediately if it behaves abnormally.
- CAUTION Always handle with care to avoid injury from the sharp tip. Ensure that the probe is completely dry before use. Do not allow liquids to enter the probe. Take care to avoid mechanical stress or tight bends on the arm and cable connecting the probe head to the oscilloscope. Mishandling will degrade performance and measurement accuracy and is not covered by the warranty. Avoid all kinds of mechanical shock to the probe assembly.
Overview
- Probe head
- Pinhead connector (signal)
- Probe arm
- a. Probe base (with magnet)
- b. Flexible arm
- c. Probe arm grip
Getting started
- Attach the probe head to the probe arm with the M4 thread
- Connect your instrument to the pin head connector
Operating Instructions
- Position the probe – Place the probe foot on the base plate and the magnet will keep it in place.
- Reposition the probe – Slide the probe foot on the base plate.
- Detaching the probe – Tilt the probe foot gently and remove the probe arm. Avoid pulling in the flexible arm!
Measuring with the probe
- Lift the probe in the probe grip
- Compress the needle to the measuring target
- Release the probe grip gently
Probe needle replacement
- Notice the replaceable needle tip. Please be aware of the sharp needle tip!
- Pull out the replaceable needle tip by hand or use pliers.
- Pick up the new needle tip and insert it in the sleeve with pliers.
Specifications
Model | SP10 |
---|---|
**Bandwidth > (MHz)*** | 10 |
Rise time (ns), calculated | 34 |
Attenuation Ratio | 1 |
Needle Resistance (ohm) < | 0.02 |
Full-scale measurement
range (for safe operation) Maximum Input: 1:1 Input Voltage, Fulfill the signal voltage limits of EN 61010-031:2015
|
Voltage: +/-60 V DC, 30 V AC RMS, +/-42.4 V
pk max.
Overvoltage protection (voltage that will not damage)|
200 V DC + peak AC
Maximum DC (A)| 2
Operating Environment, Max. altitude 2km|
-40 to +80 °C, 0 to 80% RH
Storage Environment, Max. altitude 15km| -40 to +80 °C, 0 to 80% RH
Probe tip diameter (mm)| 0.5
Pollution Degree| 2 (As defined in IEC 61010-031. Only non-conductive
pollution. Occasionally, however, a temporary conductivity caused by
condensation must be accepted.)
RoHS and REACH compliant| Yes
The probe and cable are not impedance matched and are suitable for measurements below 10MHz, frequencies above 10 MHz can still be measured but with increased signal distortion on rising and falling edges using an oscilloscope. The probe and cable are tested above 25 MHz with correct data decoding with a common logic analyzer.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>