Factors Affecting Air Quality
Carbon dioxide(CO2) is a colorless and odorless gas usually derived from the
breath of humans and animals. High CO2 concentration means that fresh air or
ventilation is required; otherwise, it may cause problems such as drowsiness,
dizziness, loss of attention, and cognitive impairment.
Temperature & Humidity may often be ignored. However, they do have a
significant impact on an individual’s well-being, comfort, health and safety,
as well as your property. High Humidity may lead to an increase in household
air pollutants, especially the biological contaminants such as molds,
bacteria, viruses, and dust mites; cold, low Humidity may cause nosebleeds,
skin and respiratory irritations, dyspnea, static electricity, etc.
Important
★ Do not expose the detector to heavily contaminated environments for long
periods, as this can damage the sensor.
★ Do not use the detector for long periods in environments with a strong,
irritating smell to ensure accurate measurements.
★ Do not dismantle the unit yourself. In the event of a defect, contact your
dealer instead, who will liaise with the service center and, if necessary,
send the device in for repair.
★ Children should only use this device under adult supervision. Keep packaging
materials, such as plastic bags and plastic wrap, out of the reach of children
as they present a choking hazard.
★If the battery level shows , please charge the detector in time to avoid
being affected during use (it can also recharge when switched off).
★ This product is intended for monitoring the health of the indoor environment
only and should not be considered a professional measurement tool.
Overview
1. Buzzer status | 5. Battery level & Charging status |
---|---|
2. CO2 level | 6. Work mode |
3. Health level display area | 7. Magnetic back |
4. Temperature & Humidity level | 8. Vents |
Overview
9Mode button | 10 Power button |
---|---|
11 USB port | 12 CO2 detection port |
13Temperature & Humidity detection port | 14 Bracket |
Specification
Model | Cl |
---|---|
CO2 | Measuring range: 400-5000ppm Resolution: 1ppm |
Accuracy: ±(40ppm +5%)
(400-2500ppm)
Temperature-| Measuring range: -10-50°C (14-140°F) Resolution: 01°C
(-9.9-70°C)
Accuracy: ±0.5°C
Humidity| Measuring range: 0-99%RH Resolution: 0.1%RH
Accuracy: ±3WoRH
When charging the product, the temperature will be ± 0.5 error and will be
recovered in about 10 minutes after the charging is completed.
When the temperature measurement environment suddenly changes, and the
temperature difference is significant, it takes 3 to 5 minutes of adaptation
time.
Dimension | 3.52.70.7 (inches) |
---|---|
Battery Capacity | 800mAh |
Work Mode* | e Power-saving mode (Sampling interval 10 min) C) Performance mode |
(Sampling interval 1 min)
Battery Life| • About 70 days
About 30 days
Input| 5V/1A
Display| Segment code screen 3.3 inches
Weight| About 110g
Operation Environment| -10-60°C/0-90WoRH
- When the product is charging, the data will keep refreshing every 5 seconds.
Note: The above data are from Temtop Laboratory.
Operation
On/Off
Buzzer switch Icon
Displayed–buzzer sound on the device is turned on;
Disappears–the buzzer sound is turned off.
Display
- The C1 has two working modes, and you can switch the working mode by pressing the mode button after powering on.
Power-saving mode (Sampling interval 10 min)
CO2 sensor works every 10 minutes.
Performance mode (Sampling interval 1 min)
CO2 sensor works every 1 minutes.
Note: If the temperature and humidity change is high, it will be refreshed
once in 5 seconds; if the temperature and humidity change is low, it will be
refreshed once in 10 seconds.
C1 monitoring function
- When the battery is displayed as empty, please charge it in time, and the charging icon will be displayed when charging.
- When the battery power is extremely low, the battery icon will flash 3 times and the shut down.
CO2 calibration
Switch on the detector in an outdoor ventilated area; Long press the and to
enter the calibration state, the CO2 title on the screen flashes, the CO2
display area starts to count down 200 seconds; the countdown ends, and the
calibration is complete.
Note:
- During manual calibration, the monitor must be exposed to fresh outdoor air (approx. 400 ppm of CO2) at least 1 meter away from people or animals.
- In calibration mode, press the button to stop calibration mode.
- Please ensure the power supply is sufficient during the calibration process. If the calibration mode is forcibly excited due to shutdown or power failure, the calibration may fail, and the data will be inaccurate, so you need to re- calibrate.
Air Quality Parameter for Reference
CO2 threshold level indication
Note: When an increase in CO2 concentration reaches a poorer level range, the buzzer alarm is triggered.
Multiple Mounting Choices
What’s Included
- Detector x 1
- USB cable x 1
- User manual x 1
- Bracket or accessories set x 1
FAQ
Q: Why are there two modes?
A: We offer two modes to cater to different usage scenarios. Mode is suitable
for situations where real-time monitoring of environmental parameters is
needed. It has a higher data collection frequency but shorter battery life.
This Mode is best suited for scenarios with frequent ecological changes, such
as traveling. For regular usage, we recommend selecting the mode. The mode is
designed for long-term monitoring, offering a longer battery life but a lower
data collection frequency.
Choose the Mode that best suits your specific needs.
Q: Why does Mode have a shorter battery life?
A: Mode has a higher data collection frequency, with data being collected every minute. Therefore, it has a relatively shorter battery life.
Q: If I need to monitor CO2 data for an extended period continuously, will this impact the device’s lifespan?
A: According to Tiptop Laboratory’s testing, continuous real-time monitoring of CO2 data for an extended period has a negligible impact on the device’s lifespan.
Q: Why is the temperature high when charging?
A: The temperature and humidity sensor is located inside the product. When charging, a large amount of heat will be generated, causing the actual temperature of the product to rise.
Q: Why is CO2 data high?
A: The user’s environment may be poorly ventilated, resulting in high CO2 concentration; it is recommended that the user place the product in an outdoor ventilated place for 10 minutes. If the data is still high, the customer is advised to calibrate according to the user manual.
Warranty
Temtop warrants the included detector for 1 year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage.
Item | Warranty Period |
---|---|
Detector | 1 year included |
Accessories | N/A |
Before return or delivery for repair, please check if the following items are ready:
| Detector &
Accessories| Complete
Package| Proof of
Purchase*| Gift (if any)
---|---|---|---|---
Return| | | |
Exchange| | | |
Repair| | | |
“Including invoice, order number and etc.
Temtop warranty does NOT include:
- Malfunction or damages caused by artificial damage or modification.
- Other deliberate damages.
- Damage caused by natural events.
Elitech Technology, Inc.
2528 Qume Dr, Ste 2
San Jose, CA 95131 USA
Tel: (+1) 408-898-2866
Sales: sales@temtopus.com
Website: www.temtopus.com
Elitech Brazil Ltda
R.Dona Rosalina,90-Lgara, Canoas-RS
92410-695, Brazil
Tel: (+55)51-3939-8634
Sales: brasil@e-elitech.com
Website: www.elitechbrasil.com.br
Elitech (UK) Limited
Unit 13 Greenwich Business Park,
53 Norman Road,London, SE10 9QF
Tel: (+44)208-858-1888
Sales: sales@elitecheu.com
Website: www.temtop.co.uk
V1.0
Made in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>