Temtop P600 Air Quality Monitor Professional Indoor User Manual
- June 5, 2024
- Temtop
Table of Contents
Temtop P600 Air Quality Monitor Professional Indoor
Product Overview
Laser particle detector can accurately detect the air quality. Adopting laser particle sensor, it can directly transform the concentration of pollutants in the air into visual data and provide air quality for you to effectively safeguard the health of your family.
Application Scope
Indoors, Outdoors, Vehicles, etc.
Product Appearance
Display
Data View
Graph View
Operation Method
-
Turn on/off the detector
Press and hold the power button for 2 seconds to turn on/off the detector. No operation for lh, it will turn off too, except for the recording curve display interface. -
Det ect the concentration of PM2.5, PMlO
Turn on the detector and put it in the environment which needs testing, then the system will automatically detect the concentration of PM2.5, PMlO. -
Power indication
The detector has the function of testing the battery power. When it is IIIID , the battery is full; When it shows D , the battery is low. Please charge. -
Switch of display cortent
- PM2.5 Button: Press it and the system will enter PM2.5 index display interface.
- PMlO Button: Press it and the system will enter PMlO index display interface.
- Button: Press it and then the system will enter PM2.5 recording curve display interface.
- II/► Button: Under the mode of “Running” , if you press it, the system will enter detectionpause mode and all values are maintained; Under the mode of “Hold” , if you press this button, the system will reenter real time detection mode.
Product Specifications
- Name: Laser particle detector
- e Model: P600
- Display mode: TFT color LCD screen
- Battery voltage: 3.7VDC
- Overall dimension: 17765.532 mm
- Power adapter:
- Output voltage: DC5V
- Output current: lA
- Operating environment: Temperature range: 0-50°C (32-122°F) Humidity range: 0-90% RH Atmospheric pressure condition: latm
- Measurement index and range:
- PM2.5 measurement technical index
- Range: 0-999ug/m3
- Resolution: 0.lug/m3 PMl0measurement technical index
- Range: 0-999ug/m3
- Resolution: 0.lugm3
Health Parameters Guide
PM2.5
(ug/m’)
| PMl0
(ug/m’)
| ****
Level
---|---|---
0.0-12.0| 0-54| Good
12.1-35.4| 55-154| Moderate
35.5-55.4
| ****
155-254
| Unhealthy for Sensitive Groups
55.5-150.4| 255-354| Unhealthy
150.5-250.4| 355-424| Very Unhealthy
2: 250.5| 2: 4 25| Hazardous
Operation Notice
- The sensor used to detect PM2.5, PMlO adopts laser detection theory, so objects like battings and hair should be prevented from entering the detector to avoid influencing the accuracy of test data.
- Do not put the detector in the environment where the concentration of particles is more than 500ug/m3 for long time. Long-time exposure to high-concentration air pollutants will damage the sensor and make it work improperly.
- Avoid using the detector in humid environment to make sure the accuracy of test data.
- Avoid bump, strike and drop.
- Do not cover the detection port and air outlet port when using the detector.
Fault Description
Display problem: please check the battery power. If it still cannot display,
please contact the service center.
Data problem: Change the test environment and restart the detector. If the
problem still cannot solved, please contact the service center.
Packing List
- P600 Detector x 1
- USB Cable x 1
- User Manual x 1
WARRANTY
Temtop warrants the included detector for 1 year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage.
Item|
Wa rr anty Period
---|---
Detector| 1 year included
Accessories|
N/A
Before return or delivery for repair, please check if the following items are ready:
| Detector &
Accessories
| Complete
Package
| Proof of
**Purchase***
|
Gift (if any)
---|---|---|---|---
Return| | –| |
Exchange| –| –| –|
Repair| –| | –|
Temtop warranty does NOT include:
- Malfunction or damages caused by artificial damage or modification.
- Other deliberate damages.
- Damages caused by force majeure.