Clarke PSV3A 8m Head Dirty Water Submersible Pump Instruction Manual

June 5, 2024
Clarke

Clarke LOGO **PUMPClarke PSV3A 8m Head Dirty Water Submersible
Pump SUBMERSIBLE PUMPS
MODEL NO: PSV3A, PSV4A, PSSV2A & PVP11A
PART NO: 7236042, 7236044, 7236050 & 7236060

ORIGINAL INSTRUCTIONS
INSTRUCTIONS
GC0221 – rev 8
**

INTRODUCTION

Thank you for purchasing this CLARKE Submersible Pump.
This pump is designed for pumping clean/dirty water only. it is not designed for pumping slurry, sludge, mud, heavily polluted water, or any water containing chemicals or other acidic contaminants including saltwater.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase.

This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.

Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.

This guarantee does not affect your statutory rights.

ENVIRONMENTAL RECYCLING POLICY

Through the purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery, and environmentally sound disposal of the WEEE.

In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognized disposal facility.

SAFETY PRECAUTIONS

WORK AREA
  1. Keep the work area clean and well-lit. Floors should always be kept clear. Cluttered or dark areas invite accidents.
  2. Keep children and bystanders away while operating the pump. Distractions can cause a loss of control.
  3. Remember, the operator or user is responsible for accidents or hazards occurring to other people or their property.
PERSONAL SAFETY
  1. Always stay alert, watch what you are doing, and use common sense when operating this pump. Do not install the pump while you are tired or under the influence of medication, drugs, or alcohol. A moment of inattention can result in personal injury.
  2. Do not over-reach. Keep your proper footing and balance at all times when positioning the pump.
  3. Never direct the water discharge towards electrical wiring or equipment.
  4. Always store the pump out of reach of children and do not allow persons unfamiliar with these instructions to operate it.
  5. Never direct the discharge flow towards another person.
  6. Always thoroughly familiarise yourself with this pump & its operation and follow all instructions in this manual.
  7. Always ensure that the pump is properly positioned where necessary to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear.
GENERAL USE AND CARE OF THE PUMP
  1. An approved Residual Current Device (RCD) must be used when pumping from ponds or swimming pools.
  2. Always lift the pump using the handle and use a rope or chain attached if necessary to lower it into the pit or excavation. Never lift or carry the pump by the power cable or by the float switch cable.
  3. Never use this pump if any part is damaged. Has it been inspected and repaired by your local Clarke dealer?
  4. Always use an extension cable suitable for outdoor use when operating outdoors. Using the correct cable reduces the risk of electric shock.
  5. Always maintain the pump with care and keep it clean.
  6. Always use an approved cable extension suitable for the power rating of the pump (see specifications). The conductor size should also be at least the same size as that on the pump or larger. When using a cable reel, always unwind the cable completely.
  7. Never use it for pumping flammable liquids or corrosive chemicals. These pumps are designed to pump water only.
  8. Never abuse the electrical cable. Never use the cable for pulling or unplugging the pump Damaged or tangled cables increase the risk of electric shock.
  9. Never run the pump dry. Always ensure the pump is immersed in water before starting. Switch the pump OFF immediately after the task is completed
  10. Never pump water from a swimming pool when there is a person or animal still in the pool.
  11. Never install the pump on sand, silt, or mud which is likely to shift or collapse.
  12. Never modify this pump in any way. Use it only for the purpose for which it is designed.
SERVICING & REPAIRS
  1. Always have the pump serviced by your local CLARKE dealer, using only identical replacement parts. This will ensure the safety of the pump is maintained. The use of nonstandard parts could be hazardous.
  2. Never attempt any repairs yourself. If you have a problem with the pump contact your local CLARKE dealer.
  3. Always disconnect the pump from the electrical supply before placing it into, or removing it from the water, and before any cleaning or maintenance.
  4. If the power cable becomes damaged, it must be replaced rather than repaired.

Your CLARKE water pump has been designed to give long and trouble-free service. If, however, having followed the instructions in this booklet carefully, you encounter problems, take the unit to your local CLARKE dealer.
Please keep these instructions in a safe place for future reference.

ELECTRICAL CONNECTIONS

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY.

Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz. Connecting it to any other power source may cause damage.

This product may be fitted with a non-rewireable plug. If it is necessary to change the fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or damaged, the plug must not be used until a suitable replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or due to damage, it should be cut off and a replacement fitted, following the wiring instructions shown below. The old plug must be disposed of safely, as insertion into the main socket could cause an electrical hazard.

WARNING! THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH
If the colors of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug, proceed as follows.

  • The wire which is colored blue must be connected to the terminal which is marked N or colored Black.
  • The wire which is colored brown must be connected to the terminal which is marked L or colored Red.
  • The wire which is colored Yellow and Green must be connected to the terminal which is marked E or or colored Green.

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
1

We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD)
If in any doubt, consult a qualified electrician.

OVERVIEW

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
2

SUITABILITY

The CLARKE range of submersible pumps is suitable for discharging pools, ponds, fountains, pits, and any wastewater drainage. They can handle foul water containing suspended material as listed in the specification. The pumps are not suitable for handling inflammable, corrosive, explosive, or dangerous liquids.

THE FLOAT SWITCH

The float switch enables the pump to stop and restart automatically as the surrounding water level changes. As the water level rises, the switch will float and start the pump. As the water level falls, so will the float switch, until it stops the pump. Float switches are factory set to provide the correct ON-OFF switching mode. This makes them suitable for permanent or semi- permanent installations, eg. installations where it is necessary to maintain water at a particular level without an operator in attendance.

THE THERMAL CUT-OUT

The pump is provided with a thermal overload cut-out so that in the event that the pump becomes overheated (due to becoming blocked etc) it will shut off automatically. When the blockage has been cleared, the thermal cutout will cool down and re-set and the pump can be re-started.

CONNECTION AND POSITIONING

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
3

  1. Screw the outlet elbow and stepped adaptor supplied, onto the outlet of the pump as shown.

  2. Connect the outlet adaptor to the largest diameter hose available, as any restriction will reduce capacity and put unnecessary strain on the motor.
    • The stepped adaptor fitting allows for connection of 32 mm (1¼”), or 25 mm (1”) hoses which should be secured with a hose clamp.

  3. Ensure that the hose diameter is as large as possible if a long run of discharge hose is being used.
    • Suitable hoses are available from your local Clarke dealer.

POSITIONING THE PUMP
  1. ALWAYS raise and lower the pump using a rope attached to the lifting handle.
  2. Place the pump in a vertical position resting on a firm, flat surface in the area that you want to drain. If there is sediment in the operating area, the pump should be placed vertically on house bricks, or similar but ensure they are not likely to collapse. Never position the pump on sand, silt, mud, or ground which is likely to collapse.
  3. Keep the pump clear of sediment by standing it on a platform or brick or suspending it from a rope attached to the handle if the pump is to be used where there may be silt or mud etc (e.g. garden ponds).
  4. Ensure the pump is positioned with adequate space so that the movement of the float switch is not restricted – recommended minimum area of 50 x 50cm.
  5. Allowance must also be made for the overall width of the pump including the outlet elbow on one side.
  6. Ensure the float switch has sufficient room to operate correctly if used in a confined space such as a shaft or sump.
    • The pump should only be placed in a sump that is large enough not to restrict the movement of the float switch.
    • When the pump is being used in a permanent or semi-permanent installation, a nonreturn valve should be fitted in the delivery hose. Suitable hoses and valves are available from your Clarke dealer.

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
4

USING THE PUMP

WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE PUMP IF IT IS DAMAGED IN ANY WAY.
WARNING: THE WATER BEING PUMPED WILL BE POLLUTED IF THIS PUMP BECOMES DAMAGED AND LUBRICANT WITHIN THE PUMP ESCAPES.

  1. Plugin the pump and switch on the power supply.
    • Always use a high sensitivity residual current device (RCD) which has a tripping current of less than 30mA.
    • The pump will only run where there is sufficient water for the float switch to rise and activate the pump.

  2. If required, the range of operation of the float switch can be manually adjusted by positioning the float switch cable within the retaining clip at the top of the pump. The switch will operate through its full range if left hanging free.

  3. Run the pump continuously or remove it from the water and store it in a frost-free location if the water is likely to freeze.

  4. Never run the pump dry. Ensure the pump switches off when the water has stopped flowing.
    • The pump should be able to clear water down to a residual depth of approx 35mm, provided the float switch has been raised to keep the pump running. In this situation, air and residual water may be seen escaping from the vent valve.

  5. Disconnect from the power supply when the water has been pumped out. Avoid running the pump continuously if the discharge hose has become obstructed and water is not flowing.

AUTOMATIC THERMAL OVERLOAD

These pumps are fitted with automatic thermal overload protection. If the pump overheats due to an obstruction in the pump or pumping warm water, for example, it will shut off automatically.
Switch the pump OFF at the main supply. Check for blockages and allow the motor to cool (at least 5 minutes) before attempting to restart, by which time the cut-out will have reset.

CLEANING, MAINTENANCE & STORAGE

WARNING: MAKE SURE THAT THE PUMP IS DISCONNECTED FROM THE POWER SUPPLY BEFORE CLEANING OR PERFORMING MAINTENANCE

The pump should require no maintenance other than regular inspection and cleaning.

  1. Inspect the pump prior to use and do not use the pump if there is any damage to the mains power cable or to the float switch or its connecting cable.
  2. Check the pump regularly to ensure the inlet is clear of leaves or other debris. It can be cleaned out either by back-flushing or by removing the base plate (after undoing the retaining screws) and cleaning it out by hand.
  3. If the pump has been used for pumping swimming pool water or salty water likely to leave chemical residues, it should be flushed through with clean water before storage.
  4. When the pump is not being used for extended periods, clean and dry it thoroughly and store it indoors. if the pump is left in water, it should be run at least once a week to prevent it from seizing up.

If the pump shows signs of wear or damage, contact your CLARKE dealer for advice. Do not attempt to repair the pump yourself, as you may damage the waterproof seals and invalidate your guarantee. Repairs should be carried out by your local CLARKE dealer, or contact the CLARKE Service Department on 020 8988 7400.

ACCESSORIES

A wide range of accessories is available from your nearest CLARKE dealer, including hoses and hose adaptors.

TROUBLESHOOTING

PROBLEM

|

SOLUTION

---|---
The pump hums but does not run| 1. Impeller partially clogged. Raise pump and clean.
• If the pump is clear, the motor could be defective.
The pump runs but does not deliver water or only delivers a small amount| 1. Check or non-return valve is installed backward. The arrow on the valve should point in direction of flow.
2. Discharge shut-off valve if used, may be closed. Check that the outlet is not clogged or obstructed.
3. Impeller partially clogged. Raise pump and clean.
4. Air bubbles in the pump, produced during immersion. immerse the pump again, at an angle, and shake it whilst lowering to remove any air trapped in the system.
5. Inlet at the base of the pump is blocked. Raise pump and clear openings.
6. Vertical pumping distance too high. Reduce height or change the pump discharge fitting.
7. Impeller may be damaged – Consult your CLARKE dealer.
The pump will not start| 1. Make sure that the power is switched on.
2. Check fuse (consult an electrician if in doubt).
3. If an extension lead is fitted, check connections (consult an electrician if in doubt).
4. Internal thermal cut-out has not re-set. Leave for 5-10 minutes and try again.
5. The impeller may be jammed. Disconnect from the mains supply and remove any objects that may be obstructing the impeller.
6. Float switch may be jammed against the sidewall, or prevented from moving.
7. If the pump still fails to start, consult your CLARKE dealer for advice.
The pump runs but will not stop| 1. Float switch may be prevented from moving to the fully down position.
2. Faulty float switch. Consult your CLARKE dealer.
Fuse blows or circuit breaker trips when the pump starts| 1. Motor may be defective.
2. Fuse size is wrong or the circuit breaker may be too small
3. Pump clogged. Raise pump and clean impeller
Pump stops running| 1. Thermal overload has operated. Leave for 5-10 minutes and try again.
2. Pump has run dry, or float switch has cut in.
3. A foreign object has jammed the impeller.

SPECIFICATIONS

Feature PSV3A PSV4A PSV4A PVP11A
Outlet Thread Dia 1½” BSP 1½” BSP 1½” BSP 1½” BSP
Outlet Size 38mm 38mm 38mm 38mm
Voltage 230 Vac 230 Vac 230 Vac 230 Vac
Motor Wattage at Max flow rate 400 W 750 W 750 W 1100 W
Fuse Rating 5 amp 13 amp 13 amp 13 amp
Cable Length 10 m 10 m 10 m 10 m
IP Rating IPX8 IPX8 IPX8 IPX8
Maximum Head Height 8 M 8 M 8 M 11 M
Maximum Depth 5 m 5 m 5 m 5 m
Maximum Flow 133 l/min 216 l/min 208 l/min 258 l/min
Maximum Water Temperature 35ºC3 35ºC3 35ºC3 35ºC3
Maximum Particle Size 35 mm 35 mm 35 mm 35 mm
Weight 4.15 kg 5.15 kg 6.25 kg 6.95 kg

PARTS LIST PSV3A & PSV4A

No Description No Description
1 Power Cable 20 Motor Front Cover
2 Float Switch 21 Washer
3 3-point Self Tapping Screw 22 Cable Sheath
4 Top Housing 23 O-Ring
5 Cable Entry Sheath 24 Adjusting Shim Washer
6 Cable Entry Gland 25 Impeller
7 Capacitor 8uF 26 Nut
8 Cable Gland 27 Main Pump Housing
9 Cable Holder 28 Steel Ball
10 Screw 29 Washer
11 Rear Motor Cover 30 Screw
12 Wave Washer 31 O-ring
13 Bearing 32 Pump Base
14 Motor Rotor 33 Screw
15 Grommet 34 Outlet Elbow
16 Stator 35 O-Ring
17 Frame Seal 36 Reducing Adaptor
18 Front Bush Assembly 37 Base Plate
19 O-ring Seal 38 Self-tapping Screw

Part number = NJP-PSV3A-01 etc.

PARTS DIAGRAM-PSV3A & PSV4A

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
5

PARTS LIST PSSV2A

No Description No Description
1 Power Cable 25 O-Ring
2 Float Switch 26 Motor Front Cover
3 Dome headed Bolt 27 Shim Washer
4 Handle 28 Impeller
5 Nut 29 Nut
6 Bolt 30 O-ring
7 Main Pump Body 31 Compression Ring
8 8O-ring 32 Bolt
9 Pump Rear Housing 33 Ground Bracket
10 Cable Entry Sheath 34 Locating Ring
11 Cable Sheath 35 Sealing Washer
12 Cable Gland 36 Base Cover Ring
13 Capacitor 8uF 37 Pump Base
14 Cable Block 38 Base Plate
15 Bolt 39 Self-tapping Screw
16 Rear Motor Cover 40 Outlet Elbow
17 Wave Washer 41 O-ring
18 Bearing 42 Reducing Adaptor
19 Motor Rotor 43 Mechanical Seal
20 Motor Stator 44 Protective Ring
21 Bush 45 Air Vent
22 Washer 46 46 Steel Ball
23 Frame Seal 47 O-Ring
24 Aluminium Bush 48 Air Vent Nut

Part number = NJP-PSSV2A-01 etc.

PARTS DIAGRAM-PSSV2A

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
6

PARTS LIST PVP11A

No Description No Description
1 Power Cable 24 AirVent
2 Float Switch 25 Motor Stator
3 3-point Self Tapping Screw 26 Frame Seal
4 Handle 27 Front Motor Bush
5 Nut 28 O-Ring
6 S/t Screw 29 Front Motor Cover
7 Main Pump Body 30 Mechanical Seal
8 O-Ring 31 Adjusting Shim Washer
9 Pump Rear Housing 32 Shim Washer
10 Cable Entry Sheath 33 Impeller
11 Cable Gland 34 Nut
12 Capacitor 8uF 35 O-Ring
13 Cable Block 36 Compression Ring
14 Screw 37 Screw
15 Rear Motor Cover 38 Grounding Bracket
16 Cable Gland 39 Securing Ring
17 Wave Washer 40 Sealing Washer
18 Bearing 41 Pump Base
19 Motor Rotor 42 Outlet Elbow
20 Cable Sheath 43 O-Ring
21 Air Vent Nut 44 Reducing Adaptor
22 Steel Ball 45 Cable Gland
23 O-Ring 46 Cable Clamp

Part number = NJP-PVP11A-01 etc.

PARTS DIAGRAM-PVP11A

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
7

PUMP PERFORMANCE GRAPHS

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
8

DECLARATION OF CONFORMITY PSV3A

Clarke LOGO 2 INTERNATIONAL
Hemnall Street, Epping, Essex CM16 4LG
DECLARATION OF CONFORMITY
This is an important document and should be retained.

We hereby declare that this product(s) complies with the following directive(s):
2014/30/EU Electromagnetic Compatibility Directive.
2014/35/EU Low Voltage Equipment Directive.
2011/65/EU Restriction of Hazardous Substances (Amended by (EU) 2015/863).

The following standards have been applied to the product(s):
EN 60335-1:2012+A11+A13, EN 60335-2-41:2003+A1+A2, EN 62233:2008, EN 55014-1:2017,
EN 55014-2:2015, EN 61000-3-2:2014, EN 61000-3-3:2013.

The technical documentation required to demonstrate that the product(s) meet(s) the requirement(s) of the aforementioned directive(s) has been compiled and is available for inspection by the relevant enforcement authorities.

The CE mark was first applied in: 2008

Product Description: Submersible Pump
Model number(s): PSV3A
Serial/batch Number: n/a
Date of Issue: 02106/2020
Signed:


J.A. Clarke
Director

Sub pump PSV3A I rv2) No20-0004

**DECLARATION OF CONFORMITY PSSV2A

**

Clarke LOGO 2 INTERNATIONAL
Hemnall Street. Epping, Essex CM16 41G
DECLARATION OF CONFORMITY
This is an important document and should be retained.

We hereby declare that this product(s) complies with the following directive(s):
2014/30/EU Electromagnetic Compatibility Directive.
2014/35/EU Low Voltage Equipment Directive.
2011/65/EU Restriction of Hazardous Substances (Amended by (EU) 2015/863).

The following standards have been applied to the product(s):
EN 60335-1:2012+A11+A13, EN 60335.2-41:2003+A 1+A2, EN 62233:2008, EN 55014-1:2017,
EN 55014-2:2015, EN 61000-3-2:2014, EN 61000-3-3:2013.

The technical documentation required to demonstrate that the product(s) meet(s) the requirement(s) of the aforementioned directive(s) has been compiled and is available for inspection by the relevant enforcement authorities.

The CE mark was first applied in: 2008

Product Description: Submersible
Pump Model number(s): PSV4A
Serial/batch Number: n/a
Date of Issue: 02/06/2020
Signed:

J.A. Clarke
Director

Sub pump PSV4A (rv2) No20-0005

DECLARATION OF CONFORMITY PSSV2A

Clarke LOGO 2 INTERNATIONAL
Hemnall Street. Epping, Essex CM16 41G
DECLARATION OF CONFORMITY
This is an important document and should be retained.

We hereby declare that this product(s) complies with the following directive(s):
2014/30/EU Electromagnetic Compatibility Directive.
2014/35/EU Low Voltage Equipment Directive.
2011/65/EU Restriction of Hazardous Substances (Amended by (EU) 2015/863).

The following standards have been applied to the product(s):
EN 60335-1:2012+A11+A13, EN 60335-2-41:2003+A1+A2, EN 62233:2008, EN 55014-1:2017,
EN 55014-2:2015, EN 61000-3-2:2014, EN 61000-3-3:2013.

The technical documentation required to demonstrate that the product(s) meet(s) the requirement(s) of the aforementioned directive(s) has been compiled and is available for inspection by the relevant enforcement authorities.

The CE mark was first applied in: 2008

Product Description: Submersible
Pump Model number(s): PSSV2A
Serial/batch Number: n/a
Date of Issue: 02/0612020
Signed:

J.A. Clarke
Director

Sub pump PSSV2A Ov2) No20-0007

DECLARATION OF CONFORMITY PVP11A

Clarke LOGO 2 Hamnall Street, Epping, Essex CM16 4LG
DECLARATION OF CONFORMITY
This is an important document and should be retained.

We hereby declare that this product(s) complies with the following directive(s):
2014/30/EU Electromagnetic Compatibility Directive.
2014/35/EU Low Voltage Equipment Directive.
2011/65/EU Restriction of Hazardous Substances (Amended by (EU) 2015/863).

The following standards have been applied to the product(s):
EN 60335-1:2012+A11+A13, EN 60335-2-41:2003+Al+A2, EN 62233:2008, EN 55014-1:2017,
EN 55014-2:2015, EN 61000-3-2:2014, EN 61000-3-3:2013.

The technical documentation required to demonstrate that the product(s) meet(s) the requirement(s) of the aforementioned directive(s) has been compiled and is available for inspection by the relevant enforcement authorities.

The CE mark was first applied in: 2008

Product Description: Submersible
Pump Model number(s): PVP11A
Serial/batch Number: n/a
Date of Issue: 02/06/2020
Signed:

J.A. Clarke
Director

Sub pump PVP11 A (rv2) No20-0006

NOTES

………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….
………………………………………………………………………………………………………………………………………………………………………….

A SELECTION FROM THE VAST RANGE OF

Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
10| Clarke
LOGO| Clarke PSV3A 8m Head Dirty Water Submersible Pump - FIG
11
---|---|---
QUALITY PRODUCTS
AIR COMPRESSORS
From DIY to industrial, Plus air tools, spray guns, and accessories.
GENERATORS
Prime duty or emergency standby for business, home, and leisure.
POWER WASHERS
Hot and cold, electric and engine driven – we have what you need
WELDERS
Mig, Arc, Tig, and Spot. From DIY to auto/industrial.
METALWORKING
Drills, grinders, and saws for DIY and professional use.
WOODWORKING
Saws, sanders, lathes, mortisers, and dust extraction.
HYDRAULICS
Cranes, body repair kits, and transmission jacks for all types of workshop use.
WATER PUMPS
Submersible, electric, and engine drove for DIY, agriculture, and industry.
POWER TOOLS
Angle grinders, cordless drill sets, saws, and sanders.
STARTERS/CHARGERS
All sizes for car and commercial use.

PARTS & SERVICE:
0208 988 7400
Parts Enquiries
Parts@clarkeinternational.com
Servicing & Technical Enquiries
Service@clarkeinternational.com
SALES: UK 01992 565333 or Export 00 44 (0)1992 565335
Clarke LOGO 2INTERNATIONAL
Hem nail Street, Epping, Essex CM16 4LG
www.clarkeinternational.com

Documents / Resources

| Clarke PSV3A 8m Head Dirty Water Submersible Pump [pdf] Instruction Manual
PSV3A, PSV4A, PSSV2A, PVP11A, 8m Head Dirty Water Submersible Pump
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals