VIQUA IHS10-D4 IHS12-D4 IHS22-D4 ultraviolet (UV) water system Owner’s Manual
- June 5, 2024
- VIQUA
Table of Contents
VIQUA IHS10-D4 IHS12-D4 IHS22-D4 ultraviolet (UV) water system
Congratulations on the purchase of your ultraviolet (UV) water system!
This system uses the most advanced UV technology on the market and is designed
to provide you with years of trouble free operation with minimal maintenance.
To ensure ongoing optimal operation, UV lamps need to be replaced annually
with VIQUA factory-supplied replacements. VIQUA lamps are the result of
extensive development resulting in a highly efficient platform with extremely
stable UV output over the entire 9000 hour lifetime. Its success has led to a
proliferation of non-genuine copies in the market.
The UV lamp is the heart of the UV system, and there should be no compromise
when it’s time for a replacement.
Why should you insist on genuine factory supplied VIQUA replacement lamps?
- Use of widely available, non-genuine, replacement lamps has been shown to damage the control module of VIQUA UV equipment.
- An increasing number of calls to VIQUA Technical Support are connected with non-genuine lamps being used (unknowingly) as replacements.
- Damage arising from the use of non-genuine lamps poses a safety risk and is not covered by equipment warranty.
- Unless the UV equipment is equipped with a UV sensor (monitor), it is not possible to verify the UV (invisible) output of replacement lamps.
- Similar appearance to the original lamp and the presence of (visible) blue light does not mean equivalent performance.
- VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised.
So, you can see that it’s simply not worth the risk! Insist on genuine VIQUA replacement lamps.
Safety Information
These are the original instructions. Please read this entire manual before
operating this equipment. Pay attention to all danger, warning, and caution
statements in this manual. Failure to do so could result in serious personal
injury or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. DO
NOT use or install this equipment in any manner other than that specified in
the installation manual.
Potential Hazards:
Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed.
Safety Precautions:
DANGER
| Failure to follow these instructions will result in serious injury or death.
• Electric Shock: To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, DO NOT attempt repairs yourself, refer to an authorized service facility.
• GROUNDING: This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with this system – if it does not fit in the outlet, have a proper outlet installed by a qualified electrician. DO NOT use any type of adapter with this system.
• GROUND FAULT CIRCUIT INTERRUPTER PROTECTION : To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not exceeding 30 mA. Inspect operation of GFCI as per manufacturer’s suggested maintenance schedule.
• DO NOT operate the UV system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any manner.
• DO NOT use this UV system for other than intended use (potable water applications). The use of attachments not recommended or sold by the manufacturer / distributor may cause an unsafe condition.
• DO NOT install this UV system where it will be exposed to the weather or to temperatures below freezing.
• DO NOT store this UV system where it will be exposed to the weather.
• DO NOT store this UV system where it will be exposed to temperatures below freezing unless all water has been drained from it and the water supply has been disconnected.
WA R N I N G
UV
| • During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
• Do not pass water through the UV system for a minimum of 5 minutes after applying power (including after power interruptions) to avoid passing under-treated water that may, in rare instances, pose health hazards.
• This system contains a UV Lamp. Do not operate the UV Lamp when it is removed from the chamber. Unintended use or damage of the system may result in the exposure of dangerous UV radiation. UV radiation may, even in little doses, cause harm to the eyes and skin.
• Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void the manufacturer’s warranty.
**| WARNING:** This product can expose you to chemicals including phthalates, which is known to the state of California to cause cancer, and mercury, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
CAUTION
Failure to follow these instructions could result in minor or moderate injury.
- Carefully examine the UV system after installation. It should not be plugged in if there is water on parts not intended to be wet such as, the controller or lamp connector.
- Due to thermal expansion concerns and potential material degradation due to UV exposer, it is recommended to use metal fittings and at least 10” of copper pipe on the outlet of your UV chamber.
- Hg EXPOSURE: The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for the removal and disposal of mercury waste.
NOTICE
| • The UV systems have been validated through microbial testing. Through this testing, performance data has been generated for UV dose delivery to inactivate Cryptosporidium, Giardia, Escherichia coli (E. Coli) and Fecal Coliform.
| • The UV lamp inside the UV system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the UV lamp annually.
• The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, are also not to handle the UV system unless they have been given supervision or instruction.
• This system is intended to be permanently connected to the water lines.
• This system is not intended to be used in or above water or outdoors or used in swimming pools when persons are in the pool.
• EXTENSION CORDS : If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an electrical rating not less than the rating of the system. A cord rated for less amperes or watts than this system rating may overheat. Exercise caution when arranging the cord so that it will not be tripped over or pulled. DO NOT use damaged extension cords. Examine extension cord before using and replace if damaged. DO NOT abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always grasp the plug and pull to disconnect.
• If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
• SYSTEM PROTECTION: To protect your Controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is strongly recommended.
• The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations (CFR) requirements including, Title 21, Chapter 1, Subchapter J, Radiological Health.
• Read and understand the Owner’s Manual before operating and performing any maintenance on this equipment.
Water Chemistry
Water quality is extremely important for the optimum performance of your UV system. The following levels are recommended for installation:
Water Quality and Minerals | Level |
---|---|
Iron | < 0.3 ppm (0.3 mg/L) |
Hardness* | < 7 gpg (120 mg/L) |
Turbidity | < 1 NTU |
Manganese | < 0.05 ppm (0.05 mg/L) |
Tannins | < 0.1 ppm (0.1 mg/L) |
UV Transmittance | > 75% (call factory for recommendations on applications |
where UVT < 75%)
- Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is cleaned periodically. If total hardness exceeds 7 gpg, the water should be softened. If your water chemistry contains levels in excess of those mentioned above, proper pre-treatment is recommended to correct these water problems prior to the installation of your UV system. These water quality parameters can be tested by your local dealer, or by most private analytical laboratories. Proper pre-treatment is essential for the UV system to operate as intended.
General Information
Item | Description | Part Number | UV System |
---|---|---|---|
1 | Sump wrench | WR40-50 | Used on all systems. |
2 | Sediment filter | CMB-510-HF | IHS12-D4, IHS10-D4 |
CMB-520-HF | IHS22-D4 | ||
3 | O-ring | OR40-50 | Used on all systems. |
4 | Bracket | – | – |
5 | Lamp connector | – | Used on all systems. |
6
|
Power cord
| 602636 (120V)| IHS12-D4, IHS22-D4, IHS10-D4
602637 (230V)| IHS12-D4/2, IHS22-D4/2, IHS10-D4/2
260013 (Australian)| IHS12-D4/2A, IHS22-D4/2A, IHS10-D4/2A
260012 (UK)| IHS12-D4/2B, IHS22-D4/2B, IHS10-D4/2B
7
| Controller
(includes Controller mounting bracket, Reference card)
|
650733R-002
|
Used on all systems.
8| Reference card| 603069| Used on all systems.
9| Controller mounting bracket| –| –
10| Lamp (includes O-rings)| 602805| IHS12-D4, IHS22-D4, IHS10-D4
11| O-ring| –| Used on all systems.
12| Sleeve bolt| 602665| Used on all systems.
13| Sleeve (includes O-rings)| 602732| IHS12-D4, IHS22-D4, IHS10-D4
14| UV Chamber (includes Chamber and Ring clamp).| –| Used on all systems.
15| Carbon filter| C2-02PB| IHS12-D4, IHS22-D4
Dimensions and Layout
Item | Description | Function |
---|---|---|
1 | Main water shut-off valve | Allows for sampling of raw water. |
2 | Shut-off Valve | Allows for ease of maintenance of whole home UV system. |
3 | Bypass shut-off valve | Bypass line and valve are optional. Intended to |
provide emergency water supply in the event that the UV system is unavailable.
4| Shut-off valve| Allows for ease of maintenance of whole home UV system.
5| Whole Home System| Provides filtration and treatment of the water.
6| Controller| Powers and controls the UV lamp. Provides human interface,
displaying information and allowing control inputs (such as muting the audible
alarm).
7
|
Power source
| Provides power to the controller. For safety reasons the outlet must be protected by a Ground Fault Circuit Interrupter (GFCI).
Note: To protect the controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is required.
Installation
Installing UV System
CAUTION
Electronic controller must be connected to a Ground Fault Protected Circuit
(GFCI) receptacle. Ensure green ground wire ring terminal is securely fastened
to ground stud on UV chamber.
Prerequisites:
- Determine appropriate indoor location of the controller and chamber, refer to Section 2.1.
- Make sure that the controller is installed higher than the chamber and away from all water sources.
- Ensure adequate clearance above chamber to allow for removal of the lamp and sleeve.
- Make sure to turn off the main water supply.
- Make all necessary plumbing connections refer to Section 2.1.
Procedure: Cleaning Procedure
CAUTION The sump housings will be heavy.
Prerequisites:
Reapply a generous amount of lubricant to the O-ring when reinstalling sumps.
Procedure:
Maintenance
WA R N I N G
| • Always disconnect power before performing any work on the UV system.
• Always shut-off water flow and release water pressure before servicing.
• Regularly inspect your UV system to ensure that the power indicators are on and no alarms are present.
• Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum performance.
• Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
• During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
Replacing UV Lamp
NOTICE Do not use water during replacement of UV lamp.
Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 hours of continuous operation (approximately one year) in order to ensure adequate performance.
Procedure:
Cleaning and Replacing Quartz Sleeve
Note: Minerals in the water slowly form a coating on the quartz sleeve. This
coating must be removed because it reduces the amount of UV light reaching the
water, thereby reducing performance. If the sleeve can not be cleaned, it must
be replaced.
Prerequisites:
- Shut off water supply and drain all lines.
- Depressurize the unit. Place a small pail under the unit to catch any spills.
- Remove the UV lamp. Refer to Section 4.1.
Procedure:
-
Unscrew the sleeve bolt and carefully remove it from the top of the chamber.
Note: Sleeve may be attached to sleeve bolt. Hold sleeve with other hand while removing sleeve bolt. -
Clean the quartz sleeve with a cloth soaked in CLR, vinegar or some other mild acid and then rinse with water.
Note: If sleeve cannot be cleaned completely or it is scratched or cracked, then replace the sleeve. -
Place O-ring on the sleeve as shown. Insert the sleeve into the chamber as shown in step 4.
-
Ensure quartz sleeve is properly centered in the chamber.
-
Place sleeve bolt onto the quartz sleeve, carefully push down and hand tighten onto chamber. When service is complete, assemble the prerequisites in the reverse order of disassembly.
Notes:
- After replacing the UV lamp or sleeve perform the cleaning procedure, refer to Section 3.2.
- If the system is put on a temporary by-pass or if it becomes contaminated, it is necessary to complete the cleaning procedure. Refer to Section 3.2.
Replacing Cartridges
CAUTION: The sump housings will be heavy.
It is recommended to change the filter cartridges regularly, approximately 3-4 times per year depending on water quality and usage. A gradual drop in water pressure after the filtration device is an indication that the pre-filter cartridges are nearing the end of their useful life.
Procedure:
Operation
Controller
Buttons and Display
Feature| Description| Function
A| Lamp timer display| Counts down from 365 days to show time for annual lamp
replacement.
B| Lamp timer reset| After installing a new lamp, press and hold for five
seconds to reset Lamp timer to 365.
C
|
Mute
| Press to silence audible alarm.
When the alarm is due to the lamp’s age, the mute button will silence the
audible alarm for 7 days; this may be repeated up to a maximum of 4 times.
After that, the button will silence for only 24 hours.
When the alarm is due to any other issue, the mute button will silence the
audible alarm for 24 hours.
Indicator Lights
Normal Operating Conditions
| LED 1
(UV Controller Status)
| LED 2
(UV Lamp Status)
| Audio Indicator Status|
Notes
Lamp warm-up| Green| Flashing Green| Off| It may take up to 2.5 minutes for
the lamp to warm up and the LED 2 to be solid green.
Normal Operation| Green| Green| Off|
Alarm/Fault Condition
| LED 1
(UV Controller Status)
| LED 2
(UV Lamp Status)
| Audio Indicator Status|
Notes
---|---|---|---|---
UV Lamp Ignition/Run Fault
|
Red
|
Flashing Red
|
Beeping
| 1. Unplug UV system from main power supply.
2. Check for secure lamp connection.
3. Restore power to UV system.
4. If failure message repeats, replace UV lamp. Audible alarm may be silenced for 24 Hours.
UV Lamp Near End of Life Warning| Green| Yellow| Off| Warning: Lamp will
require replacement shortly.
UV Lamp At End of Life Fault| Green| Flashing Red| Chirp| 1. Follow
instructions in manual to replace lamp. Warning Chirp may be silenced for 7
Days.
UV Lamp EOL Exceeded Fault| Green| Flashing Red| Chirp| 1. Follow
instructions in manual to replace lamp. Warning Chirp may be silenced for 24
Hours.
AC Voltage out of Range
|
Flashing Red
| Flashing Red|
Beeping
| When the AC voltage is back in range (>93V or <265V) the alarm cancels and normal operation is resumed.
Audible alarm may be silenced temporarily.
UV Controller Fault
|
Flashing Red
|
Red
|
Beeping
| 1. Unplug UV system from main power supply.
2. Allow 30 seconds for unit to fully power down.
3. Restore power to UV system.
4. If failure message repeats, replace controller. Audible alarm may be silenced for 24 Hours.
Troubleshooting
Symptom | Possible Cause | Possible Solution |
---|
No power
| GFCI and/or breaker tripped| Reset GFCI and/or breaker
Transient voltage surge suppressor (TVSS) damaged| Replace TVSS
Controller damaged| Replace controller and use a TVSS
GFCI or breaker repeatedly trips
| Connection between lamp and lamp plug is wet| Clean and dry lamp pins and
lamp plug, check unit for leaks or condensation
Short-circuit in the electrical assembly| Replace controller
Leak at inlet or outlet| Threaded pipe fittings are leaking| Clean threads,
reseal with Teflon tape and retighten
Leak detected from area of UV chamber
| Condensation of moist air on cold chamber (slow accumulation)| Control
humidity or relocate unit
O-ring damaged, deteriorated or incorrectly installed| Inspect and replace if
deteriorated
Lamp/sleeve assembly not properly installed (too tight or not tight enough)|
Tighten assembly hand-tight
Alarm| Refer to Section 5.1.| Refer to Section 5.1.
System is operating but water tests reveal bacterial contamination
| Equipment downstream of UV system is acting as a breeding ground for
pathogens| Ensure UV is the last piece of treatment equipment
Pathogens are residing in the distribution lines post-UV| Ensure all
distribution lines have been disinfected with chlorine. Refer to Section 3.2.
Recontamination from pipe dead-ends| Remove any pipe dead-ends and flush with
chlorine. Refer to Section 3.2.
Lamp timer does not read anything
| Unit is unplugged| Plug unit into AC power outlet
No power at AC power outlet| Replace fuse or reset breaker
Power cord is damaged| Replace power cord
Power surge caused damage to electrical assembly| Replace controller and use a
surge protector (TVSS)
Leak detected at filters
| O-ring damaged, deteriorated or incorrectly installed| Remove the sump, wipe
the O-ring and threads clean. ensure the O-ring is fitted properly, then
reinstall
Filter cartridge not centered| Remove sump, check for cartridge damage, re-
assemble ensuring cartridge is centered
Specifications
IHS12-D4 | IHS22-D4 | IHS10-D4 | |
---|---|---|---|
Operating Parameters | |||
Maximum operating pressure | 100 PSI (689 kPa) | 100 PSI (689 kPa) | 100 PSI (689 |
kPa)
Minimum operating pressure| 4 PSI (27.5 kPa)| 4 PSI (27.5 kPa)| 4 PSI (27.5
kPa)
Maximum ambient air temperature| 122 ºF (50 ºC)| 122 ºF (50 ºC)| 122 ºF (50
ºC)
Minimum ambient air temperature| 36 ºF (2 ºC)| 36 ºF (2 ºC)| 36 ºF (2 ºC)
Maximum humidity| 95%| 95%| 95%
Maximum hardness| 120 ppm (7 grains per gallon)| 120 ppm (7 grains per
gallon)| 120 ppm (7 grains per gallon)
Maximum iron| 0.3 ppm| 0.3 ppm| 0.3 ppm
Minimum UVT| 75%| 75%| 75%
Flow Rates| |
Maximum rated flow at dose of 16 mJ/cm2| 16 gpm (60 lpm) (3.6 m3/hr)| 16 gpm
(60 lpm) (3.6 m3/hr)| 16 gpm (60 lpm) (3.6 m3/hr)
Maximum rated flow at dose of 30 mJ/cm2| 12 gpm (45 lpm) (2.7 m3/hr)| 12 gpm
(45 lpm) (2.7 m3/hr)| 12 gpm (45 lpm) (2.7 m3/hr)
Maximum rated flow at dose of 40 mJ/cm2| 9 gpm (34 lpm) (2 m3/hr)| 9 gpm (34
lpm) (2 m3/hr)| 9 gpm (34 lpm) (2 m3/hr)
Electrical|
Voltage2| 100-240 V| 100-240 V| 100-240 V
Frequency| 50/60 Hz| 50/60 Hz| 50/60 Hz
Max. current| 1 A| 1 A| 1 A
Max. power consumption| 50 Watts| 50 Watts| 50 Watts
Lamp power| 40 Watts| 40 Watts| 40 Watts
Other|
UV Chamber Material| 304 SST| 304 SST| 304 SST
Inlet/Outlet3| 3/4” NPT| 3/4” NPT| 3/4” NPT
Other**|
Rated service life of lamp| 1 year| 1 year| 1 year
UV System Certification
| ****
| ****
| ****
1 The max flow rate is determined by the carbon filter.
** Flow rates shown are at 95% UVT and End of Lamp Life; 20°C.
2 Units ending in “/2” are for 230V applications.
3 Units ending in “/2B” have BSPT connections.
4 Units ending in */NOM are Certified to the Mexican NOM standard.
|
Manufacturer’s Warranty
Our Commitment
VIQUA is committed to ensuring your experience with our products and
organization exceeds your expectations. We have manufactured your UV system to
the highest quality standards and value you as our customer. Should you need
any support, or have questions about your system, please contact our Technical
Support team at 1.800.265.7246 or technicalsupport@viqua.com and we will be
happy to assist you.
How to Make a Warranty Claim
Note: To maximise the performance and reliability of your VIQUA product, the
system must be properly sized, installed and maintained. Guidance on the
necessary water quality parameters and maintenance requirements can be found
in your Owner’s Manual.
In the event that repair or replacement of parts covered by this warranty are required, the process will be handled by your dealer. If you are unsure whether an equipment problem or failure is covered by warranty, contact our Technical Support team at 1.800.265.7246 or e-mail technicalsupport@viqua.com. Our fully trained technicians will help you troubleshoot the problem and identify a solution. Please have available the model number (system type), the date of purchase, the name of the dealer from whom you purchased your VIQUA product (“the source dealer”), as well as a description of the problem you are experiencing. To establish proof of purchase when making a warranty claim, you will either need your original invoice, or have previously completed and returned your product registration card via mail or online.
Specific Warranty Coverage
Warranty coverage is specific to the VIQUA range of products. Warranty
coverage is subject to the conditions and limitations outlined under “General
Conditions and Limitations”.
Ten-Year Limited Warranty for VIQUA UV Chamber
VIQUA warrants the UV chamber on the VIQUA product to be free from defects in
material and workmanship for a period of ten (10) years from the date of
purchase. During this time, VIQUA will repair or replace, at its option, any
defective VIQUA UV chamber. Please return the defective part to your dealer
who will process your claim.
Three-Year Limited Warranty for Electrical and Hardware Components
VIQUA warrants the electrical (controller) and hardware components to be free
from defects in material and workmanship for a period of three (3) years from
the date of purchase. During this time, VIQUA will repair or replace, at its
option, any defective parts covered by the warranty. Please return the
defective part to your dealer who will process your claim.
One-Year Limited Warranty for UV lamps, Sleeves, and UV Sensors
VIQUA warrants UV lamps, sleeves, and UV sensors to be free from defects in
material and workmanship for a period of one (1) year from the date of
purchase. During this time, VIQUA will repair or replace, at its option, any
defective parts covered by the warranty.Your dealer will process your claim
and advise whether the defective item needs to be returned for failure
analysis.
Note: Use only genuine VIQUA replacement lamps and sleeves in your system.
Failure to do so may seriously compromise performance and affect warranty
coverage.
General Conditions and Limitations
None of the above warranties cover damage caused by improper use or
maintenance, accidents, acts of God or minor scratches or imperfections that
do not materially impair the operation of the product. The warranties also do
not cover products that are not installed as outlined in the applicable
Owner’s Manual.
Parts repaired or replaced under these warranties will be covered under
warranty up to the end of the warranty period applicable to the original part.
The above warranties do not include the cost of shipping and handling of
returned items.The limited warranties described above are the only warranties
applicable to the VIQUA range of products. These limited warranties outline
the exclusive remedy for all claims based on a failure of or defect in any of
these products, whether the claim is based on contract, tort (including
negligence), strict liability or otherwise. These warranties are in lieu of
all other warranties whether written, oral, implied or statutory. Without
limitation, no warranty of merchantability or of fitness for a particular
purpose shall apply to any of these products.
VIQUA does not assume any liability for personal injury or property damage
caused by the use or misuse of any of the above products. VIQUA shall not in
any event be liable for special, incidental, indirect or consequential
damages. VIQUA’s liability shall, in all instances, be limited to repair or
replacement of the defective product or part and this liability will terminate
upon expiration of the applicable warranty period.