VIQUA IHS22-E4 Ultraviolet UV Water System Owner’s Manual
- June 1, 2024
- VIQUA
Table of Contents
- VIQUA IHS22-E4 Ultraviolet UV Water System
- Section 1: Safety Information
- Section 2: General Information
- Section 3: Installation
- Section 4: Operation
- Section 5: Maintenance
- Section 6: Troubleshooting
- Section 7: Specifications
- Section 8: Manufacturer’s Warranty
- Specifications
- FAQ
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VIQUA IHS22-E4 Ultraviolet UV Water System
OWNER’S MANUAL
Model: IHS22-E4
Congratulations on the purchase of your ultraviolet (UV) water system! This system uses the most advanced UV technology on the market and is designed to provide you with years of trouble free operation with minimal maintenance.
To ensure ongoing optimal operation, UV lamps need to be replaced annually with VIQUA factory-supplied replacements. VIQUA lamps are the result of extensive development resulting in a highly efficient platform with extremely stable UV output over the entire 9000 hour lifetime. Its success has led to a proliferation of non-genuine copies in the market.
The UV lamp is the heart of the UV system, and there should be no compromise when it’s time for a replacement.
Why should you insist on genuine factory supplied VIQUA replacement lamps?
- Use of widely available, non-genuine, replacement lamps has been shown to damage the control module of VIQUA UV equipment.
- An increasing number of calls to VIQUA Technical Support are connected with non-genuine lamps being used (unknowingly) as replacements.
- Damage arising from the use of non-genuine lamps poses a safety risk and is not covered by equipment warranty.
- Unless the UV equipment is equipped with a UV sensor (monitor), it is not possible to verify the UV (invisible) output of replacement lamps.
- Similar appearance to the original lamp and the presence of (visible) blue light does not mean equivalent performance.
- VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised.
So, you can see that it’s simply not worth the risk! Insist on genuine VIQUA replacement lamps.
Section 1: Safety Information
These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this equipment in any manner other than that specified in the installation manual.
1.1 Potential Hazards
Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed.
| Waste electrical and electronic equipment (WEEE). This symbol indicates that
you should not discard wasted electrical or electronic equipment (WEEE) in the
trash. For proper disposal, contact your local recycling/reuse or hazardous
waste center.| | This symbol indicates not to store any combustible or
flammable material close to the system.
---|---|---|---
| This symbol indicates there is Mercury present.| | This symbol indicates
that the contents of the transport package are fragile and the package should
be handled with care.
| This is the safety alert symbol. Obey all safety messages that follow this
symbol to avoid potential injury. When on the equipment, refer to the
Operational and Maintenance manual for additional safety information.| | This
symbol indicates safety glasses with side protection is required for
protection against UV exposure.
| This symbol indicates a risk of electrical shock and/or electrocution
exists.| | This symbol indicates gloves must be worn.
| This symbol indicates the marked equipment may contain a component that can
eject forcibly. Obey all procedures to safely depressurize.| | This symbol
indicates safety boots must be worn.
| This symbol indicates the system is under pressure.| | This symbol indicates
the operator must read all available documentation to perform required
procedures.
| This symbol indicates there is a potential UV hazard. Proper protection must
be worn.| | This symbol indicates the plumber must use copper piping.
| This symbol indicates the marked item could be hot and should not be touched
without care.| | This symbol indicates that the system should only be
connected to a properly grounded, grounding-type controller receptacle that is
protected by a Ground Fault Circuit Interrupter (GFCI).
| This symbol indicates there is a potential for VERY hot water when flow is
started.|
1.2 Safety Precautions
DANGER
Failure to follow these instructions will result in serious injury or death.
- Electric Shock: To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs yourself, refer to an authorized service facility.
- GROUNDING: This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with this system – if it does not fit in the outlet, have a proper outlet installed by a qualified electrician. Do not use any type of adapter with this system.
- GROUND FAULT CIRCUIT INTERRUPTER PROTECTION: To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not exceeding 30 mA. Inspect operation of GFCI as per manufacturer’s suggested maintenance schedule.
- DO NOT operate the UV system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any manner.
- DO NOT use this UV system for other than intended use (potable water applications). The use of attachments not recommended or sold by the manufacturer / distributor may cause an unsafe condition.
- DO NOT install this UV system where it will be exposed to the weather or to temperatures below freezing.
- DO NOT store this UV system where it will be exposed to the weather.
- DO NOT store this UV system where it will be exposed to temperatures below freezing unless all water has been drained from it and the water supply has been disconnected.
Safety Information
WARN I NG
-
During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time.
To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system. -
Do not pass water through the UV system for a minimum of 5 minutes after applying power (including after power interruptions) to avoid passing under-treated water that may, in rare instances, pose health hazards.
-
This system contains a UV Lamp. Do not operate the UV Lamp when it is removed from the chamber. Unintended use or damage of the system may result in the exposure of dangerous UV radiation. UV radiation may, even in little doses, cause harm to the eyes and skin.
-
Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void the manufacturer’s warranty.
WARNING: This product can expose you to chemicals including phthalates, which is known to the state of California to cause cancer, and mercury, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
CAUTION
Failure to follow these instructions could result in minor or moderate injury.
- Carefully examine the UV system after installation. It should not be plugged in if there is water on parts not intended to be wet such as, the controller or lamp connector.
- Due to thermal expansion concerns and potential material degradation due to UV exposure, it is recommended to use metal fittings and at least 10″ of copper pipe on the outlet of your UV chamber.
- Hg EXPOSURE: The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for the removal and disposal of mercury waste.
NOTICE
- The UV system has been validated through microbial testing. Through this testing, performance data has been generated for UV dose delivery to inactivate Cryptosporidium, Giardia, Escherichia coli (E. Coli) and Fecal Coliform.
- The UV lamp inside the UV system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the UV lamp annually.
- The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, are also not to handle the UV system unless they have been given supervision or instruction.
- This system is intended to be permanently connected to the water lines.
- This system is not intended to be used in or above water or outdoors or used in swimming pools when persons are in the pool.
- EXTENSION CORDS: If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an electrical rating not less than the rating of the system. A cord rated for less amperes or watts than this system rating may overheat. Exercise caution when arranging the cord so that it will not be tripped over or pulled. DO NOT use damaged extension cords. Examine extension cord before using and replace if damaged. DO NOT abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always grasp the plug and pull to disconnect.
- If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
- SYSTEM PROTECTION: To protect your Controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is strongly recommended.
- The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations (CFR) requirements including, Title 21, Chapter 1, Subchapter J, Radiological Health.
- Read and understand the Owner’s Manual before operating and performing any maintenance on this equipment.
1.3 Water Chemistry
Water quality is extremely important for the optimum performance of your UV system. The following levels are recommended for installation:
Water Quality and Minerals | Level |
---|---|
Iron | < 0.3 ppm (0.3 mg/L) |
Hardness* | < 7 gpg (120 mg/L) |
Turbidity | < 1 NTU |
Manganese | < 0.05 ppm (0.05 mg/L) |
Tannins | < 0.1 ppm (0.1 mg/L) |
UV Transmittance | > 75% (call factory for recommendations on applications |
where UVT < 75%)
- Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is cleaned periodically. If total hardness exceeds 7 gpg, the water should be softened. If your water chemistry contains levels in excess of those mentioned above, proper pre-treatment is recommended to correct these water problems prior to the installation of your UV system. These water quality parameters can be tested by your local dealer, or by most private analytical laboratories. Proper pre-treatment is essential for the UV system to operate as intended.
Section 2: General Information
Item | Description | Part Number | UV Systems |
---|---|---|---|
1 | Sump wrench | WR40-50 | Used on all systems. |
2 | Sediment filter | CMB-520-HF | Used on all systems. |
3 | O-ring | OR40-50 | Used on all systems. |
4 | Bracket | – | – |
5 | Lamp connector | – | Used on all systems. |
6 | Power cord | 602636 (120V) | IHS22-E4 |
602637 (230V) | IHS22-E4/2 |
260013
(Australian)| IHS22-E4/2A
260012 (UK)| IHS22-E4/2B
7| Controller (includes Controller mounting bracket, Lamp connector)|
650733R-001| Used on all systems.
8| Controller mounting bracket| –| –
9| Lamp (includes O-rings)| 602806| Used on all systems.
10| O-ring| 002045| Used on all systems.
11| Sleeve bolt| 602665| Used on all systems.
12| Sleeve (includes O-rings)| 602733| Used on all systems.
13| UV Chamber (includes Chamber and Ring clamp).| 660082-R| Used on all
systems.
14| Carbon filter| C2-02PB| Used on all systems.
General Information
To find out what model you have, look at the label on the side of the controller as depicted below:
Support Screen Programming – For Dealers and Installers Only
Dealers/Installers can personalize this Screen with their company logo and contact information such as Company Name, Company Phone Number and Company Website. This can be easily done by downloading the Dealer Logo Programming Software from the Viqua website: WWW.VIQUA.COM/LCD.
2.1 Dimensions and Layout
Item | Description | Function |
---|---|---|
1 | Main water shut-off valve | Allows for sampling of raw water. |
2 | Shut-off Valve | Allows for ease of maintenance of whole home UV system. |
3 | Bypass shut-off valve | Bypass line and valve are optional. Intended to |
provide emergency water supply in the event that the UV system is unavailable.
4| Shut-off valve| Allows for ease of maintenance of whole home UV system.
5| Whole Home System| Provides filtration and UV.
6| Controller| Powers and controls the UV lamp and other devices. Provides
human interface, displaying information and allowing control inputs (such as
muting the audible alarm).
7| Power source| Provides power to the controller. For safety reasons the
outlet must be protected by a Ground Fault Circuit Interrupter (GFCI).
Note: To protect the controller, a UL1449 certified (or equivalent) transient
voltage surge suppressor is required.
Section 3: Installation
CAUTION
Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely fastened to ground stud on UV chamber.
Note: Red wire is only used as a strain relief for the ground wire.
3.1 Installing UV System
Prerequisites:
- Determine appropriate indoor location of the controller and chamber, refer to Section 2.1.
- Make sure that the controller is installed higher than the chamber and away from all water sources.
- Ensure adequate clearance above chamber to allow for removal of the lamp and sleeve.
- Make sure to turn off the main water supply.
- Make all necessary plumbing connections refer to Section 2.1.
Procedure:
-
Install the UV system on the wall using lag bolts (not supplied). Mounting holes are located in the metal bracket.
-
Slide controller onto mounting bracket.
-
Connect power cord to controller.
-
DO NOT connect the power cord to the GFCI outlet at this time.
-
Place O-ring on the sleeve as shown. Insert the sleeve into the chamber as shown in step 5.
-
Ensure quartz sleeve is properly centered in the chamber.
-
Place sleeve bolt onto the quartz sleeve, carefully push down and hand tighten onto chamber.
-
Insert lamp into the quartz sleeve and thread into sleeve bolt until hard stop.
-
Connect the green ground wire and red strain relief wire to the chamber using the grounding screw.
-
Align connection pins with the lamp connector by rotating the ring clamp.
-
Push the lamp connector down onto the lamp pins and the ring clamp pins until an audible click is heard. Note: Ensure the connector is engaged on both sides.
-
Connect power.
-
Open all faucets and turn on water supply. Inspect for any leaks.
Note: Outlet must be protected by a Ground Fault Circuit Interrupter (GFCI).
3.2 Cleaning Procedure
CAUTION
The sump housings will be heavy.
Prerequisites:
- Reapply a generous amount of lubricant to the O-ring when reinstalling sumps.
Procedure:
It is imperative that the entire distribution system located after the UV be chemically cleaned to ensure that the plumbing system is free from any contaminants. The cleaning process must be performed immediately after the UV unit is installed and repeated thereafter whenever the UV is shut down for service, without power, or inoperative for any reason. The procedure for cleaning the plumbing system is readily accomplished as follows:
-
Ensure the controller is plugged in for entire cleaning process.
-
Shut off the water supply.
-
Close each faucet.
-
Press the pressure button to release the pressure from the cartridges
-
Remove the drain plug at the bottom of the sump and place a pail to catch the water.
-
Reinstall the drain plug.
-
Remove the sump housings using sump wrench.
-
Remove cartridges and pour 2 cups of household bleach solution into the sump housings.
Note: DO NOT use Hydrogen Peroxide.
-
Reinstall the housings.
-
Open all faucets and turn on the cold water supply followed by hot water (if available) until you smell the bleach.
-
Close all faucets and allow bleach in the water lines for 30 minutes.
-
Shut off the water supply.
-
Remove both housings.
-
Reinstall both the cartridges and housings.
-
Flush all water outlets until bleach can no longer be smelled (at least 5 minutes).
-
Press the pressure button to purge air to complete the cleaning procedure.
-
Inspect for any leaks.
Section 4: Operation
4.1 Control Panel
Feature | Description | Function |
---|---|---|
A | Status Screen | Displays the following: |
• Lamp life days
• Product information
• Product support
• UV level status
• Active alarms
B| Pushbutton 1| • Scroll
• Mute
• 24Hr Mute
• Cancel
C| Pushbutton 2| • Lamp reset
• Select
• Close
• Reset hold 5 Sec
4.2 Controller Start Up
The following screens appear for 4 seconds when you connect the controller to power:
4.3 Resetting the Lamp Life Timer back to 365 Days
4.4 List of All Alarms
4.5 Model Selection For Replacement Controllers ONLY
Determine the part number of your System below and find the associated MODEL for that system. When power is applied the new Controller will show the MODEL SELECTION Screen for 4 seconds. During this time press the Scroll button until the Model that represents your system is highlighted in RED. Press the Select button to select the model. This ensures the associated replacement parts for your system are displayed on the Product Information Screen.
Part Number | Description | Model |
---|---|---|
650695-R | SYS, D4+ HOME 120V | D4+ |
650697-R | SYS, D4+ HOME 230V | D4+ |
660042-R | SYS, D4-V+ NSF Class B 120VAC | D4-V+ |
660089-R | SYS, D4 PREMIUM 120V | D4 Premium |
660090-R | SYS, D4 PREMIUM 230V | D4 Premium |
650682 | SYS, E4 PROFESSIONAL 120VAC | E4 |
650718 | SYS, E4 PROFESSIONAL 230VAC | E4 |
660040-R | SYS, E4-V NSF Class B 120VAC | E4-V |
650683 | SYS, E4+ PROFESSIONAL 120VAC | E4+ |
650719 | SYS, E4+ PROFESSIONAL 230VAC | E4+ |
660043-R | SYS, E4-V+ NSF Class B 120VAC | E4-V+ |
650638-R | SYS, E4+ PROFESSIONAL+ 50%UVT 120V | E4-50+ |
650639-R | SYS, E4+ PROFESSIONAL+ 50%UVT 240V | E4-50+ |
IHS22-E4 | SYS, E4 PROFESSIONAL 2SUMP 120VAC | IHS22-E4 |
IHS22-E4/2 | SYS, E4 PROFESSIONAL 2SUMP 230V CEE7/7 | IHS22-E4 |
IHS22-E4/2A | SYS, E4 PROFESSIONAL 2SUMP 230V AS3112 | IHS22-E4 |
IHS22-E4/2B | SYS, E4 PROFESSIONAL 2SUMP 230V BS1363 | IHS22-E4 |
650686 | SYS, F4 PROFESSIONAL 120VAC | F4 |
650686 | SYS, F4 PROFESSIONAL 230VAC | F4 |
660041-R | SYS, F4-V NSF Class B 120VAC | F4-V |
650687 | SYS, F4+ PROFESSIONAL 120VAC | F4+ |
650721 | SYS, F4+ PROFESSIONAL 230VAC | F4+ |
660044-R | SYS, F4-V+ NSF Class B 120VAC | F4-V+ |
650640-R | SYS, F4+ PROFESSIONAL 50%UVT 120V | F4-50+ |
650641-R | SYS, F4+ PROFESSIONAL 50%UVT 240V | F4-50+ |
4.6 Dry Contact Connection Information
The UVMax Controller is supplied with a Dry Contact Connection which allows connection to a remote device such as a Solenoid Valve or remote alarm indicator when a major alarm occurs with the UV system.
4.6.1 Alarm Descriptions
The Dry Contact Output will inform you on the following Major Alarms:
1. Low UV Failure
2. Controller Failure
3. Lamp Failure
4. UV Sensor Failure
Dry Contact Connection Logic Chart
Output Connection| UV System Running Normally
(No Major Alarms)| UV System Is In a Major Alarm or No Power is Connected to
the UV System
Normally Open Contact (NO)| The Electrical path between these contacts are
closed| The Electrical path between these contacts are open
Common (COM)
Normally Closed Contact (NC)| The Electrical path between these contacts are
open| The Electrical path between these contacts are closed
Common (COM)
Section 5: Maintenance
WARN I NG
- Always disconnect power before performing any work on the UV system.
- Always shut-off water flow and release water pressure before servicing.
- Regularly inspect your UV system to ensure that the power indicators are on and no alarms are present.
- Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum performance.
- Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
- During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
5.1 Replacing UV Lamp
NOTICE
Do not use water during replacement of UV lamp.
Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 hours of continuous operation (approximately one year) in order to ensure adequate performance.
Procedure:
-
Close all faucets and water supply.
-
Press the pressure release button to relieve the pressure from the cartridges.
-
Disconnect main power source and allow the unit to cool for 10 minutes.
-
Remove the lamp connector by pulling the tabs out and then upwards.
-
Hold sleeve bolt with one hand and turn lamp counter-clockwise and pull the lamp outside the chamber in upward direction.
-
Insert new lamp into the quartz sleeve and thread into sleeve bolt until hard stop.
-
Connect the green ground wire and red strain relief wire to the chamber using the grounding screw.
-
Align connection pins with the lamp connector by rotating the ring clamp.
-
Push the lamp connector down onto the lamp pins and the ring clamp pins until an audible click is heard.
Note: Ensure the connector is engaged on both sides.
- Reset lamp timer.
5.2 Cleaning and Replacing Quartz Sleeve
Note: Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing performance. If the sleeve can not be cleaned, it must be replaced.
Prerequisites:
- Shut off water supply and drain all lines.
- Depressurize the unit. Place a small pail under the unit to catch any spills.
- Remove the UV lamp. Refer to Section 5.1.
Procedure:
Unscrew the sleeve bolt and carefully remove it from the top of the chamber.
Note: Sleeve may be attached to sleeve bolt. Hold sleeve with other hand
while removing sleeve bolt.
Clean the quartz sleeve with a cloth soaked in CLR, vinegar or some other mild
acid and then rinse with water.
Note: If sleeve cannot be cleaned completely or it is scratched or
cracked, then replace the sleeve.
-
Place O-ring on the sleeve as shown. Insert the sleeve into the chamber as shown in step 4.
-
Ensure quartz sleeve is properly centered in the chamber.
-
Place sleeve bolt onto the quartz sleeve, carefully push down and hand tighten onto chamber.
-
When service is complete, assemble the prerequisites in the reverse order of disassembly.
Notes:
-
After replacing the UV lamp or sleeve perform the cleaning procedure, refer to Section 3.2.
-
If the system is put on a temporary by-pass or if it becomes contaminated after the UV system, it is necessary to complete the cleaning procedure. Refer to Section 3.2.
5.3 Replacing Cartridges
CAUTION
The sump housings will be heavy.
It is recommended to change the filter cartridges regularly, approximately 3-4 times per year depending on water quality and usage. A gradual drop in water pressure after the filtration device is an indication that the pre-filter cartridges are nearing the end of their useful life.
Procedure:
-
Disconnect main power source and allow the unit to cool for 10 minutes.
-
Shut off the water supply.
-
Close each faucet.
-
Press the pressure button to release the pressure from the cartridges.
-
Remove the drain plug at the bottom of the sump and place a pail to catch the water.
-
Reinstall the drain plug.
-
Remove both the housing(s) using sump wrench.
-
Remove and discard the old cartridge(s).
-
Install new cartridge(s).
-
Reinstall the housing(s).
-
Open a faucet downstream of the system.
-
Restore power and turn on the water supply.
-
Close the downstream faucet.
-
Press the pressure button to purge air.
Section 6: Troubleshooting
Symptom | Possible Cause | Possible Solution |
---|---|---|
No power | GFCI and/or breaker tripped | Reset GFCI and/or breaker |
Transient voltage surge suppressor (TVSS) damaged | Replace TVSS | |
Controller damaged | Replace controller and use a TVSS | |
GFCI or breaker repeatedly trips | Connection between lamp and lamp plug is | |
wet | Clean and dry lamp pins and lamp plug, check unit for leaks or |
condensation
Short-circuit in the electrical assembly| Replace controller
Symptom| Possible Cause| Possible Solution
---|---|---
Leak at inlet or outlet| Threaded pipe fittings are leaking| Clean threads,
reseal with Teflon tape and retighten
Leak detected from area of UV chamber| Condensation of moist air on cold
chamber (slow accumulation)| Control humidity or relocate unit.
O-ring damaged, deteriorated or incorrectly installed| Inspect and replace if
deteriorated.
Lamp/sleeve assembly not properly installed (too tight or not tight enough)|
Tighten assembly hand-tight.
Alarm| Refer to Section 4.4.| Follow Fault Screen Instructions
System is operating but water tests reveal bacterial contamination| Equipment
downstream of UV system is acting as a breeding ground for pathogens| Ensure
UV is the last piece of equipment
Pathogens are residing in the distribution lines post-UV| Ensure all
distribution lines have been cleaned with chlorine. Refer to Section 3.2.
Recontamination from pipe dead-ends| Remove any pipe dead-ends and flush with
chlorine. Refer to Section 3.2.
Leak detected at filters| O-ring damaged, deteriorated or incorrectly
installed| Remove the sump, wipe the O-ring and threads clean. ensure the
O-ring is fitted properly, then reinstall
Filter cartridge not centered| Remove sump, check for cartridge damage, re-
assemble ensuring cartridge is centered
Section 7: Specifications
Operating Parameters | IHS22-E4 |
---|---|
Maximum operating pressure | 100 PSI (689 kPa) |
Minimum operating pressure | 4 PSI (27.5 kPa) |
Maximum ambient air temperature | 104 ºF (40 ºC) |
Minimum ambient air temperature | 32 ºF (0 ºC) |
Maximum humidity | 95% |
Maximum hardness | 120 ppm (7 grains per gallon) |
Maximum iron | 0.3 ppm |
Minimum UVT | 75% |
Flow Rates | |
Maximum rated flow at dose of 16 mJ/cm2** | N/A1 |
Maximum rated flow at dose of 30 mJ/cm2** | 22 gpm (83 lpm) (4.95 m3/hr) |
Maximum rated flow at dose of 40 mJ/cm2** | 16 gpm (60 lpm) (3.6 m3/hr) |
Electrical
Voltage2| 100V-240 V
Frequency| 50/60 Hz
Max. current| 1 A
Max. power consumption| 83 Watts
Lamp power| 70 Watts
Other
UV Chamber Material| 304 SST
Inlet/Outlet3| 1″ NPT
Other
Rated service life of lamp| 1 year
UV System Certification| CE
1 The max flow rate is determined by the carbon filter.
* Flow rates based on UVT=95% and End of Lamp Life; 20°C
2 Units ending in “/2” are for 230V applications.
3 Units ending in “/2B” have BSPT connections.
4 Units ending in /NOM are Certified to the Mexican NOM standard.
Section 8: Manufacturer’s Warranty
Our Commitment
VIQUA is committed to ensuring your experience with our products and
organization exceeds your expectations. We have manufactured your UV system to
the highest quality standards and value you as our customer. Should you need
any support, or have questions about your system, please contact our Technical
Support team at 1.800.265.7246 or technicalsupport@viqua.com and we will be
happy to assist you.
How to Make a Warranty Claim
Note: To maximise the performance and reliability of your VIQUA product, the system must be properly sized, installed and maintained. Guidance on the necessary water quality parameters and maintenance requirements can be found in your Owner’s Manual.
In the event that repair or replacement of parts covered by this warranty are required, the process will be handled by your dealer. If you are unsure whether an equipment problem or failure is covered by warranty, contact our Technical Support team at 1.800.265.7246 or e-mail technicalsupport@viqua.com. Our fully trained technicians will help you troubleshoot the problem and identify a solution. Please have available the model number (system type), the date of purchase, the name of the dealer from whom you purchased your VIQUA product (“the source dealer”), as well as a description of the problem you are experiencing. To establish proof of purchase when making a warranty claim, you will either need your original invoice, or have previously completed and returned your product registration card via mail or online.
Specific Warranty Coverage
Warranty coverage is specific to the VIQUA range of products. Warranty
coverage is subject to the conditions and limitations outlined under “General
Conditions and Limitations”.
Ten-Year Limited Warranty for VIQUA UV Chamber
VIQUA warrants the UV chamber on the VIQUA product to be free from defects in
material and workmanship for a period of ten (10) years from the date of
purchase. During this time, VIQUA will repair or replace, at its option, any
defective VIQUA UV chamber. Please return the defective part to your dealer
who will process your claim.
Three-Year Limited Warranty for Electrical and Hardware Components
VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty. Please return the defective part to your dealer who will process your claim.
One-Year Limited Warranty for Lamps, Sleeves, and UV Sensors
VIQUA warrants lamps, sleeves, and UV sensors to be free from defects in material and workmanship for a period of one (1) year from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.Your dealer will process your claim and advise whether the defective item needs to be returned for failure analysis.
Note: Use only genuine VIQUA replacement lamps and sleeves in your system. Failure to do so may seriously compromise performance and affect warranty coverage.
General Conditions and Limitations
None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor scratches or imperfections that do not materially impair the operation of the product. The warranties also do not cover products that are not installed as outlined in the applicable Owner’s Manual.
Parts repaired or replaced under these warranties will be covered under
warranty up to the end of the warranty period applicable to the original part.
The above warranties do not include the cost of shipping and handling of
returned items
The limited warranties described above are the only warranties applicable to the VIQUA range of products. These limited warranties outline the exclusive remedy for all claims based on a failure of or defect in any of these products, whether the claim is based on contract, tort (including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether written, oral, implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any of these products.
VIQUA does not assume any liability for personal injury or property damage caused by the use or misuse of any of the above products. VIQUA shall not in any event be liable for special, incidental, indirect or consequential damages. VIQUA’s liability shall, in all instances, be limited to repair or replacement of the defective product or part and this liability will terminate upon expiration of the applicable warranty period.
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only)
t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069
e-mail: info@viqua.com
www.viqua.com
Specifications
-
Model: IHS22-E4
-
Powered by: 520358-R_RevM
-
Type: Ultraviolet (UV) Water System
-
Manufacturer: VIQUA
-
-
FAQ
Q: How often should I replace the UV lamp?
A: It is recommended to replace the UV lamp annually to ensure optimal performance of the water system.
References
- ABC PLUMBING, HEATING AND IRRIGATION LLC
- P65Warnings.ca.gov
- Que Faire de mes Déchets ? Découvrez les solutions pour tous vos déchets et nos conseils pour en produire moins.
- VIQUA Home Page - VIQUA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>