VIQUA S1Q-PA Sterilight UV System Owner’s Manual

June 13, 2024
VIQUA

VIQUA S1Q-PA Sterilight UV System

VIQUA-S1Q-PA-Sterilight-UV-System

Product Information

  • Models: S1Q-PA, S2Q-PA, S5Q-PA, S8Q-PA, S2Q-P/12VDC, S5Q-P/12VDC, SV5Q-PA, SV8Q-PA
  • Validated Models: SV5Q-PA, SV8Q-PA (NSF Standard 55 Class B)
  • System Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 55 for Disinfection Performance, Class B
  • Manufacturer Website: www.viqua.com

Product Usage Instructions

  1. Read the entire manual: Before operating the equipment, read the entire manual to ensure proper understanding of the product and its usage.
  2. Safety Precautions: Pay attention to all danger, warning, and caution statements in the manual to prevent personal injury or damage to the equipment.
  3. Equipment Installation: Install the equipment according to the instructions provided in the installation manual. Ensure that the protection provided by the equipment is not impaired.
  4. Potential Hazards: Familiarize yourself with the following symbols and their meanings:
    • Label and tags: Read all labels and tags attached to the system to prevent personal injury or damage to the system.
    • Waste electrical and electronic equipment (WEEE): Do not discard wasted electrical or electronic equipment (WEEE) in the trash. Contact your local recycling/reuse or hazardous waste center for proper disposal.
    • Combustible or flammable materials: Do not store any combustible or flammable material close to the system.
    • Mercury presence: This symbol indicates the presence of Mercury.
    • Fragile contents: Handle the transport package with care as its contents are fragile.
    • Safety alert symbol: Obey all safety messages following this symbol to avoid potential injury. Refer to the Operational and Maintenance manual for additional safety information.
    • Risk of electrical shock: This symbol indicates a risk of electrical shock and/or electrocution.
    • Safety glasses and gloves: Wear safety glasses with side protection and gloves for protection against UV exposure.
    • Equipment depressurization: Follow all procedures to safely depressurize the marked equipment that may contain a component that can eject forcibly.
    • Safety boots: Wear safety boots when operating the system.
    • Pressure indication: This symbol indicates that the system is under pressure.
    • Read available documentation: The operator must read all available documentation to perform required procedures.
    • UV hazard: There is a potential UV hazard, and proper UV protection must be worn.
    • Hot item: The marked item could be hot and should not be touched without care.
    • VERY hot water: Exercise caution as there is a potential for VERY hot water when flow is started.
  5. Copper piping: Use copper piping as indicated by the Cu symbol.
  6. Proper grounding: Connect the system only to a properly grounded, grounding-type controller receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI).
  7. DANGER: Follow all instructions provided in the manual to prevent serious injury or death.

Congratulations on the purchase of your ultraviolet (UV) water system! This system uses the most advanced UV technology on the market and is designed to provide you with years of trouble free operation with minimal maintenance.
To ensure ongoing optimal operation, UV lamps need to be replaced annually with VIQUA factory-supplied replacements. VIQUA lamps are the result of extensive development resulting in a highly efficient platform with extremely stable UV output over the entire 9000 hour lifetime. Its success has led to a proliferation of non-genuine copies in the market.
The UV lamp is the heart of the UV system, and there should be no compromise when it’s time for a replacement.

Why should you insist on genuine factory supplied VIQUA replacement lamps?

  • Use of widely available, non-genuine, replacement lamps has been shown to damage the control module of VIQUA UV equipment.
  • An increasing number of calls to VIQUA Technical Support are connected with non-genuine lamps being used (unknowingly) as replacements.
  • Damage arising from the use of non-genuine lamps poses a safety risk and is not covered by equipment warranty.
  • Unless the UV equipment is equipped with a UV sensor (monitor), it is not possible to verify the UV (invisible) output of replacement lamps.
  • Similar appearance to the original lamp and the presence of (visible) blue light does not mean equivalent performance.
  • VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised.

So, you can see that it’s simply not worth the risk! Insist on genuine VIQUA replacement lamps.

Section 1 Safety Information

These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any manner other than that specified in the installation manual.

Potential Hazards:
Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed.

Safety Precautions:

DANGER Failure to follow these instructions will result in serious injury or death.

  DANGER

| Failure to follow these instructions will result in serious injury or death.

•       Electric Shock: To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, DO NOT attempt repairs yourself, refer to an authorized service facility.

•       GROUNDING: This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with this system – if it does not fit in the outlet, have a proper outlet installed by a qualified electrician. DO NOT use any type of adapter with this system.

•       GROUND FAULT CIRCUIT INTERRUPTER PROTECTION : To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not exceeding 30 mA. Inspect operation of GFCI as per manufacturer’s suggested maintenance schedule.

•       DO NOT operate the UV system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any manner.

•       DO NOT use this UV system for other than intended use (potable water applications). The use of attachments not recommended or sold by the manufacturer / distributor may cause an unsafe condition.

•       DO NOT install this UV system where it will be exposed to the weather or to temperatures below freezing.

•       DO NOT store this UV system where it will be exposed to the weather.

•       DO NOT store this UV system where it will be exposed to temperatures below freezing unless all water has been drained from it and the water supply has been disconnected.

WA R N I N G

| •       During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.

•       Do not pass water through the UV system for a minimum of 5 minutes after applying power (including after power interruptions) to avoid passing under-treated water that may, in rare instances, pose health hazards.

•       This system contains a UV Lamp. Do not operate the UV Lamp when it is removed from the chamber. Unintended use or damage of the system may result in the exposure of dangerous UV radiation. UV radiation may, even in little doses, cause harm to the eyes and skin.

•       Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void the manufacturer’s warranty.

**| WARNING: This product can expose you to chemicals including phthalates, which is known to the state of California to cause cancer, and mercury, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
 
CAUTION**


| Failure to follow these instructions could result in minor or moderate injury.

•       Carefully examine the UV system after installation. It should not be plugged in if there is water on parts not intended to be wet such as, the controller or lamp connector.

•       Due to thermal expansion concerns and potential material degradation due to UV exposure, it is recommended to use metal fittings and at least 10″ of copper pipe on the outlet of your UV chamber.

•       Hg EXPOSURE : The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for the removal and disposal of mercury waste.

NOTICE

 | •       The S1Q-PA, S2Q-PA, S5Q-PA, S8Q-PA, S2Q-P/12VDC, and S5Q-P/12VDC UV systems inactivates Cryptosporidium, Giardia, Escherichia coli (E. coli) and Fecal Coliform.

•       The SV5Q-PA and SV8Q-PA UV systems inactivates heterotrophs, Escherichia coli (E. coli) and Fecal Coliform.









| •       The UV lamp inside the UV system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the UV lamp annually.

•       The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, are also not to handle the UV system unless they have been given supervision or instruction.

•       This system is intended to be permanently connected to the water lines.

•       This system is not intended to be used in or above water or outdoors or used in swimming pools when persons are in the pool.

•       EXTENSION CORDS : If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an electrical rating not less than the rating of the system. A cord rated for less amperes or watts than this system rating may overheat. Exercise caution when arranging the cord so that it will not be tripped over or pulled. DO NOT use damaged extension cords. Examine extension cord before using and replace if damaged. DO NOT abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always grasp the plug and pull to disconnect.

•       If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

•       SYSTEM PROTECTION: To protect your Controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is strongly recommended.

•       The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations (CFR) requirements including, Title 21, Chapter 1, Subchapter J, Radiological Health.

•       Read and understand the Owner’s Manual before operating and performing any maintenance on this equipment.

 | •       The Class B system or component conforms to NSF/ANSI 55 for the supplemental bactericidal treatment disinfected public drinking water or other drinking water that has been tested and deemed acceptable for human consumption by the state or local health agency having jurisdiction. The system is only designed to reduce normally occurring non-pathogenic nuisance microorganisms. Class B systems are not intended for treatment of contaminated water.

Water Chemistry

Water quality is extremely important for the optimum performance of your UV system. The following levels are recommended for installation:

Water Quality and Minerals Level
Iron < 0.3 ppm (0.3 mg/L)
Hardness* < 7 gpg (120 mg/L)
Turbidity < 1 NTU
Manganese < 0.05 ppm (0.05 mg/L)
Tannins < 0.1 ppm (0.1 mg/L)
--- ---
UV Transmittance > 75% (call factory for recommendations on applications

where UVT < 75%)

Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is cleaned periodically. If total hardness exceeds 7 gpg, the water should be softened. If your water chemistry contains levels in excess of those mentioned above, proper pre-treatment is recommended to correct these water problems prior to the installation of your UV system. These water quality parameters can be tested by your local dealer, or by most private analytical laboratories. Proper pre-treatment is essential for the UV system to operate as intended.

Section 2 General Information

VIQUA-S1Q-PA-Sterilight-UV-System-
fig-8

Item Description Part Number UV Systems

1

| Flow restrictor (Only for certified models)| 440313-R| SV5Q-PA
440314-R| SV8Q-PA
2| Lamp connector base| 270276-R| Used on all systems
3| O-ring| 410867| Used on all systems

4

|

Open-ended, 214 fused quartz sleeves with fire polished ends

| QS-001| S1Q-PA
QS-330| S2Q-PA
QS-463| S5Q-PA, SV5Q-PA
QS-810| S8Q-PA, SV8Q-PA
5| Retaining nut| RN-001| Used on all systems

6

|

Hard glass, coated UV lamps for long, consistent life (9000 hours)

| S287RL| S1Q-PA
S330RL| S2Q-PA
S463RL| S5Q-PA, SV5Q-PA
S810RL| S8Q-PA, SV8Q-PA
7| Controller (for 100-240V models only)| BA-ICE-S| S1Q-PA, S2Q-PA, S5Q-PA, S8Q-PA, SV5Q-PA, SV8Q-PA
8| Controller (for 12VDC models only)| BA-RO/P/12| S2Q-P/12VDC, S5Q-P/12VDC
9| 2.5” Mounting brackets| 410958-R| Used on all systems




10

| ****


IEC replacement power cords for VIQUA ICE Controller (sold separately)

| 602636| NORTH AMERICAN (NEMA 5-15P), 3-PRONG GROUNDED
---|---|---|---
602637| CONTINENTAL EUROPEAN (CEE 7/7) 2-PIN WITH GROUND, “SCHUKO”
260012| UK VERSION (BS 1363) 3-PRONG GROUNDED (5 AMP FUSE)
260013| AUSTRALIAN VERSION (AS 3112) 3-PRONG GROUNDED
260019| NO CONNECTOR, 3-WIRE, BARE LEADS
11| Spring| SP008| Used on all systems
12| Retaining nut with plug| RN-001/1| Used on all systems

Section 3 Installation

UV System

CAUTION Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely fastened to ground stud on UV chamber.
The UV system is designed to be mounted either horizontally or vertically at the point-of-use or point-of-entry depending on the specific flow rate of the unit.
If installing the chamber in horizontal position the outlet port must be pointing upwards to ensure all air is fully purged from the chamber.

Note: The ideal installation is vertical with the lamp connector on top. This is to prevent water damage from occurring on the lamp pins and lamp connector.

  • The controller should be mounted either above or beside the UV chamber. Always mount controller horizontally to prevent moisture from running down cordage and causing a potential fire hazard. Drip loops in all cordage connected to controller is highly recommended. Refer to Figure 6.
  • The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing with chlorine (household bleach) to destroy any residual contamination. Refer to Section 3.2.
  • The UV system is intended for indoor use only. DO NOT install UV system where it may be exposed to the weather.
  • Install the UV system on cold water line only, before any branched lines.
  • A 5 micron sediment filter must precede the UV system. Ideally, the UV system should be the last stage the water receives before it reaches the faucet.

Procedure:

  1. Figure 3 shows the installation of a typical UV system and the related components that may be used for the installation. The use of a by-pass assembly is recommended in case the system requires “off-line” maintenance. In this case, note the system requires supplementary disinfectant for the distribution system if any water is used during by-pass condition. In addition, during by-pass, the water will NOT be treated and a “DO NOT CONSUME THE WATER” tag should be physically installed on the by-pass assembly until such time as the system is sanitized and returned to service. For more information, refer to Section 3.2. If the water is to be consumed while the system is off-line, the water must be boiled for two minutes prior to consumption.VIQUA-S1Q-PA-Sterilight-UV-System-fig-10

  2. Select a suitable location for the UV system and its related components. As it is recommended to install a GFCI, make sure that this is taken into consideration prior to any installation. The system can either be installed vertically (inlet port at the bottom) as shown in Figure 4 A, or horizontally as shown in Figure 4 B. However, the vertical installation is the most preferred method. When selecting a mounting location, leave enough space to allow the removal of the UV lamp and/or quartz sleeve (typically leave a space equal to the size of the UV chamber itself).

  3. Mount the system to the wall using the supplied clamps. Various connection methods can be used to connect the water source to the system, however union type connectors are recommended. The use of a flow restrictor device will help to maintain the manufacturers rated flow. The flow restrictor should be installed on the outlet port and is designed to be installed in one direction only. Ensure that the flow of the water matches the flow direction as indicated on the flow restrictor. Refer to Figure 5.
    Note: DO NOT solder connections while attached to the system as this could damage the O-ring seals.VIQUA-S1Q-PA-Sterilight-UV-System-
fig-12

  4. Mount the VIQUA ICE controller horizontally to the wall, near the UV chamber. Ideally place the controller above the chamber and away from any water connection point, to prevent any water from potentially leaking onto the controller by means of a leak at a connection point or a “sweating” system. Make sure you allow for a “drip-loop” as shown in Figure 6 on the UV lamp, UV sensor, and power cord, again, to prevent any water from potentially entering the controller.

  5. Install the UV lamp. Refer to Section 4.1.

  6. When all plumbing connections are complete, slowly turn on the water supply and check for leaks. The most likely cause of leaks is from the O-ring seal. In case of a leak, shut water off, drain cell, remove the retaining nut, wipe the O- ring and threads. Clean and re-install.

  7. Once it is determined that there are no leaks, plug the system into the ground fault interrupter and check controller to ensure the system is operating properly. The controller should illuminate without any alarms.
    Note: DO NOT look directly at the glowing UV lamp.

  8. Allow the water to run for a few minutes to clear any air or dust that may be in the UV chamber.
    Note: When there is no flow, the water in the cell will become warm, as the UV lamp is always on. To remedy this, run a cold water tap anywhere in the house for a minute to flush out the warm water.

Cleaning Procedure

It is imperative that the entire distribution system located after the UV be chemically cleaned to ensure that the plumbing system is free from any contaminants. The cleaning process must be performed immediately after the UV unit is installed and repeated thereafter whenever the UV is shut down for service, without power, or inoperative for any reason. The procedure for cleaning the plumbing system is readily accomplished as follows:VIQUA-S1Q-
PA-Sterilight-UV-System-fig-14

Notes:

  1. The addition of chlorine (bleach) to a hot water tank that has in the past been fed with untreated raw water with high levels of other contaminants (iron, manganese, hydrogen sulphide, organics, etc.) will result in oxidation of these contaminants and may require repeated flushing of the hot water tank. This contingency must be dealt with independently under the start-up procedure for any other conditioners that may form a part of the pre-treatment for the UV unit.
  2. The above cleaning procedure will result in a massive chlorine residual far in excess of the 0.5 to 1.0 mg/L typically present in municipally chlorinated water and of a magnitude consistent with the minimum 50 mg/L chlorine solution recommended for the cleaning of distribution systems known to be contaminated. DO NOT consume water until complete system has been flushed.

Section 4 Maintenance

WARNING

  • Always disconnect power before performing any work on the UV system.
  • Always shut-off water flow and release water pressure before servicing.
  • Regularly inspect your UV system to ensure that the power indicators are on and no alarms are present.
  • Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum performance.
  • Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
Replacing UV Lamp

NOTICE

  • Reset UV lamp life timer after UV lamp replacement. Refer to Section 5.1.3. Refer to www.lamprecycle.org for UV lamp disposal.
  • DO NOT use water during replacement of UV lamp.

UV lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 hours of continuous operation (approximately one year) in order to ensure adequate performance.

Procedure:VIQUA-S1Q-PA-Sterilight-UV-System-fig-15

Cleaning and Replacing Quartz Sleeve

Note: Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing performance. If the sleeve can not be cleaned, it must be replaced.

Prerequisites:

  • Shut off water supply and drain all lines.
  • Remove the UV lamp. Refer to Section

Procedure:

VIQUA-S1Q-PA-Sterilight-UV-System-fig-16

Note: After replacing the UV lamp or quartz sleeve perform the cleaning procedure, refer to Section 3.2.

Section 5 Operation

WARNING The advanced warning system has been installed to provide the optimum protection against microbiological contamination in water. DO NOT disregard the warning signals. The best way to ensure optimum UV performance is to have the water microbiologically tested by a recognized testing agency on a regular basis.

Basic Systems Incorporating BA-ICE-S Controller

UV lamp Life Remaining (days)
The controller tracks the number of days of operation of the UV lamp and the controller. The default screen will display the total UV lamp life remaining (in days). The controller will count down the number of days remaining until the UV lamp requires changing (365 days to 1 day). At “0” days, the controller will display and sound an intermittent audible chirp (1 second on, 5 seconds off), indicating the need to change the UV lamp.

Understanding your “A3” Code

DEFERRAL – Once the “A3” or end of UV lamp life message is shown on the LED display, the audible alarm can be deferred up to 4 separate times. The delay is designed to allow you time to address the alarm while you obtain a new UV lamp. This can be done by simply depressing the timer reset button for 5 seconds, which is located on the left side of the controller. Each time the timer reset button is pressed the controller alarm is deferred seven days. Once the final 7 day deferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller timer, refer to Section 4.1.

Resetting UV lamp Life
Refer to Section 4.1.

Note: Even though the alarm on the system can be deferred for a period of time, it is important to address each and every alarm condition as they are indicating that there is a potential problem with the system and should be remedied.

Total Days of Operation
The controller also displays the total running time of the controller. To obtain this reading, press the push-button once. The total running time of the controller will be numerically displayed in days. This information will remain displayed for ten seconds and will then revert back to the UV lamp life remaining default screen. It should be noted that this value cannot be reset.

UV lamp Failure (Blank Screen)
When the system recognizes UV LAMP FAILURE (no current running through the UV lamp), the display will be blank (no default UV LAMP LIFE REMAINING screen) and the system will sound an intermittent audible tone (1 second on,1 second off). The system will remain in this state, until this condition is remedied.

12VDC Systems Incorporating BA-RO/P/12 Controller

Section 6 Troubleshooting

Symptom Possible Causes Solutions

Pressure Drop

| ****

Sediment pre-filter clogged

| Replace filter cartridge with appropriate 5 micron cartridge.

Note: Check source water supply as fluctuations may occur in source pressure.

Flow regulator| Flow regulator will result in pressure drop when approaching full flow.




High Bacteria Counts

| Quartz sleeve is stained or dirty| Clean sleeve with scale cleaner and eliminate source of staining problem (ie. soften hard water, refer to Section 4.2.
Change in feed water quality| Have source water tested to ensure that water quality is still within allowable limits for this system.
Contamination in water lines after UV system (eg. power failures, plumbing| UV system must have a bacterial free distribution system to work effectively. Refer to Section 3.2
Possible break-through of sediment through pre-filter| Have source water tested for turbidity – may need stepped filtration in order to catch all sediment entering water system (20 micron filter followed by a 5 micron filter followed by UV
Heated Product Water| Common problem caused by infrequent use of water| Run water until it returns to ambient temperature.
Water Appears Milky| Caused by air in the water lines| Run water until air is purged.



Unit Leaking Water

| Problem with O-ring seal (on retaining nut and/or UV sensor)| Ensure O-ring is in place, check for cuts or abrasions, clean O-ring, moisten with water/ lubricant and re-install, replace if necessary (410867).
Condensation on UV chamber caused by excessive humidity & cold water| Check location of UV system and control humidity.
Inadequate inlet/outlet port connections| Check thread connections, reseal with Teflon® tape and re-tighten.


System Shutting Down Intermittently

| ****

Interrupted controller

| •       Ensure system has been installed on its own circuit, as other equipment may be drawing power away from UV (ie. pump or fridge).

•       UV system should not be installed on a circuit which is incorporated into a light switch.


UV lamp Failure Alarm on – New lamp

| Loose connection between UV lamp and connector| ****

Disconnect UV lamp from connector and reconnect, ensuring that a tight fit is accomplished

Moisture build up in connector may keep UV lamp and connector from making a solid connection| ****

Eliminate chance of any moisture getting to the connector and/or lamp pins

DISPLAY FAULT MODES


LED display reads “A3”

| •       UV lamp life expired – countdown is at “0” days. Refer to Section 5.1.2, Understanding your A3 Code.

•       Press reset button for a deferred alarm, replace UV lamp


LED display is blank

| •       Controller is in UV lamp failure mode. Refer to Section 5.1.5, UV Lamp Failure. Replace UV Lamp, refer to Section 4.1.

•       Power system down, allowing it to reset itself; apply power in order to confirm that the controller is able to power UV lamp

•       Check to see if there is sufficient power to the UV system

Green LED off (12 VDC only)| •       UV lamp failure. Replace UV Lamp, refer to Section 4.1.

•       No input voltage to controller

Section 7 Manufacturer’s Dose Flow Chart

VIQUA-S1Q-PA-Sterilight-UV-System-fig-23

Section 8 Specifications: Standard and Validated


Model

| ****

S1Q- PA

| S2Q-P/12VDC/ S2Q-PA| S5Q-P/12VDC/ S5Q-PA/SV5Q-PA | S8Q-PA/ SV8Q- PA
---|---|---|---|---
Flow Rate1| ***** NSF Class B Certified 16mJ/cm2 @ 70% UVT| –| –| 5.2 gpm (19.7 lpm) (1.2 m3/ hr)| 8.7 gpm (32.9 lpm) (2.0 m3/ hr)
US Public Health 16mJ/cm2 @ 95% UVT| 3.5 gpm (13 lpm) (0.8 m3/ hr)| 5 gpm (19 lpm) (1.1 m3/hr)| 11 gpm (42 lpm) (2.5 m3/hr)| 20 gpm (75 lpm) (4.5 m3/hr)
VIQUA Standard 30 mJ/cm2 @ 95% UVT| 2 gpm (7 lpm) (0.4 m3/hr)| 3 gpm (11 lpm) (0.7 m3/hr)| 6 gpm (23 lpm) (1.4 m3/hr)| 10 gpm (38 lpm) (2.3 m3/hr)
NSF/EPA 40mJ/cm2 @ 95% UVT| 1.5 gpm (5 lpm) (0.3 m3/hr)| 2 gpm (7 lpm) (0.4 m3/hr)| 4.5 gpm (17 lpm) (1.0 m3/ hr)| 8 gpm (29 lpm) (1.8 m3/hr)


Dimensions

| Chamber| 38.1 x 6.4 cm (15″ x 2.5″)| 43.2 cm x 6.4 cm (17” x 2.5”)| 56 cm x 6.4 cm (22” x 2.5”)| 90 cm x 6.4 cm (35” x 2.5”)
Controller 100-250 VAC| 18.6 cm x 8.1 cm x 6.4 cm

(7.3” x 3.2” x 2.5”)

| 18.6 cm x 8.1 cm x 6.4 cm

(7.3” x 3.2” x 2.5”)

| 18.6 cm x 8.1 cm x 6.4 cm

(7.3” x 3.2” x 2.5”)

| 18.6 cm x 8.1 cm x 6.4 cm

(7.3” x 3.2” x 2.5”)

Controller 12 VDC| –| 13.5 cm x 4.3 cm x 5.8 cm

(5.3” x 1.7” x 2.3”)

| 13.5 cm x 4.3 cm x 5.8 cm

(5.3” x 1.7” x 2.3”)

| –
Inlet/Outlet Port Size2| 1/4” MNPT| 1/2” MNPT| 3/4” MNPT”| 3/4” MNPT
Shipping Weight| 2.7 kg (6 lbs)| 2.7 kg (6 lbs)| 2.7 kg (6 lbs)| 4.5 kg (10 lbs)


Electrical

| Voltage3| 100-240 V / 50/60 Hz| 100-240 V /

50/60 Hz

| 12 VDC| 100-240 V /

50/60 Hz

| 12 VDC| 100-240 V / 50/60 Hz
Max. Current| 0.6 A| 0.6 A| 1.8 A| 0.6 A| 1.8 A| 0.6 A
Power Consumption| 19 W| 22 W| 20 W| 30 W| 27 W| 46 W
UV lamp Watts| 14 W| 17 W| 15 W| 25 W| 20 W| 37 W
Maximum Operating Pressure| 125 psi (861 kPa)| 125 psi (861 kPa)| 125psi (861 kPa)| 125 psi (861 kPa)
Minimum Operating Pressure| 15 psi (103 kPa)| 15 psi (103 kPa)| 15psi (103 kPa)| 15 psi (103 kPa)
Ambient Water Temperature| 2-40 ºC (36-104 ºF)| 2-40 ºC (36-104 ºF)| 2-40 ºC (36-104 ºF)| 2-40 ºC (36-104 ºF)
UV Lamp Type| Standard-output| Standard-output| Standard-output| Standard- output
UV Chamber Material| 304 SS| 304 SS| 304 SS| 304 SS
1 Flow rates based on End of Lamp Life; 20°C. 2 Units ending in “/2B” have BSPT connections. 3 Units ending in “/2” are for 230V applications.

4 Units ending in */NOM are Certified to the Mexican NOM standard.

Section 9 Manufacturer’s Warranty

Our Commitment
VIQUA is committed to ensuring your experience with our products and organization exceeds your expectations. We have manufactured your UV system to the highest quality standards and value you as our customer. Should you need any support, or have questions about your system, please contact our Technical Support team at 1.800.265.7246 or technicalsupport@viqua.com and we will be happy to assist you.

How to Make a Warranty Claim
Note: To maximise the performance and reliability of your VIQUA product, the system must be properly sized, installed and maintained. Guidance on the necessary water quality parameters and maintenance requirements can be found in your Owner’s Manual.

In the event that repair or replacement of parts covered by this warranty are required, the process will be handled by your dealer. If you are unsure whether an equipment problem or failure is covered by warranty, contact our Technical Support team at 1.800.265.7246 or e-mail technicalsupport@viqua.com. Our fully trained technicians will help you troubleshoot the problem and identify a solution. Please have available the model number (system type), the date of purchase, the name of the dealer from whom you purchased your VIQUA product (“the source dealer”), as well as a description of the problem you are experiencing. To establish proof of purchase when making a warranty claim, you will either need your original invoice, or have previously completed and returned your product registration card via mail or online.

Specific Warranty Coverage
Warranty coverage is specific to the VIQUA range of products. Warranty coverage is subject to the conditions and limitations outlined under “General Conditions and Limitations”.

  • Ten-Year Limited Warranty for VIQUA UV Chamber
    VIQUA warrants the UV chamber on the VIQUA product to be free from defects in material and workmanship for a period of ten (10) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective VIQUA UV chamber. Please return the defective part to your dealer who will process your claim.

  • Three-Year Limited Warranty for Electrical and Hardware Components
    VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty. Please return the defective part to your dealer who will process your claim.

  • One-Year Limited Warranty for UV lamps, Sleeves, and UV Sensors
    VIQUA warrants UV lamps, sleeves, and UV sensors to be free from defects in material and workmanship for a period of one (1) year from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.Your dealer will process your claim and advise whether the defective item needs to be returned for failure analysis.
    Note: Use only genuine VIQUA replacement lamps and sleeves in your system. Failure to do so may seriously compromise performance and affect warranty coverage.

General Conditions and Limitations
None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor scratches or imperfections that do not materially impair the operation of the product. The warranties also do not cover products that are not installed as outlined in the applicable Owner’s Manual.
Parts repaired or replaced under these warranties will be covered under warranty up to the end of the warranty period applicable to the original part.
The above warranties do not include the cost of shipping and handling of returned items.The limited warranties described above are the only warranties applicable to the VIQUA range of products. These limited warranties outline the exclusive remedy for all claims based on a failure of or defect in any of these products, whether the claim is based on contract, tort (including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether written, oral, implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any of these products.
VIQUA does not assume any liability for personal injury or property damage caused by the use or misuse of any of the above products. VIQUA shall not in any event be liable for special, incidental, indirect or consequential damages. VIQUA’s liability shall, in all instances, be limited to repair or replacement of the defective product or part and this liability will terminate upon expiration of the applicable warranty period.

425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1

t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only)