TESLA BGL201BR Cyclone High Power Vacuum Cleaner User Manual
- June 5, 2024
- Tesla
Table of Contents
TESLA BGL201BR Cyclone High Power Vacuum Cleaner
IMPORTANT SAFETY INSTRUCTIONS
WARNING!
To reduce the risk of fire, electric shock, or injury:
- Do not leave vacuum cleaner when plugged in. Unplug from outlet when no use and before servicing.
- To reduce the risk of electric shock, do not use outdoors or on wet surfaces
- Do not allow to be used as a toy. Close attention is necessary when used by near children.
- Use only as described in this manual. Use only manufacturers recommend attachments.
- Do not use with damaged cord or plug. If vacuum cleaner is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, enter it to a service center.
- Do not pull or carry on cord, use cord as a handle, close door on cord, or pull cord around sharp edges or corners. Do not run vacuum cleaner over cord. Keep cord away from heated surfaces.
- Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
- Do not handle plug or vacuum cleaner with wet hands.
- Do not put any object into openings. Do not use with any opening blocked. Keep free of dust, lint, hair and anything that may reduce airflow.
- Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
- Turn all controls off before unplugging.
- Use extra care when cleaning on stairs.
- Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present
- Hold plug when rewinding onto cord reel. Do not allow plug to whip when rewinding.
- Unplug before connecting the hose
- Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
- Do not use without dust bag and/or filter in place.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
PRECAUTIONARY MEASURES
If the opening that sucks in the air, the suction pipe or the telescopic wand
stick on pipe are blocked, you should switch off the vacuum cleaner at once.
First clear the blocked substance before you attempt to start the vacuum
cleaner again.
ASSEMBLING VACUUM CLEANER
-
Fitting or removing the flexible hose
Fitting:
Insert flexible hose into the air intake duct on the top of appliance. Press until it clicks into position.
Removing:Removing the plug from the power socket. To release the flexible hose firmly from the air intake duct. -
Fitting the extension tubes and accessories
a. Fitting the extension tube to the handle.
b. Fitting the extension tubes.
c. Fitting Floor brush
Daily cleaning on carpets and hard floors.
INSTRUCTIONS FOR USE
Before using appliance, unwind a sufficient length of cable and insert the
plug into the power socket. A yellow mark on the power cable shows the ideal
cable length. Don’t expend the cable beyond the red mark.
- Press the ON/OFF button to switch the appliance on.
- To rewind the power cable, press the rewind button with one hand and guide the cable with the other hand to ensure that it does not whip causing damage.
- Power Control: Spin the On/Off switch (Electronic Power Control) knob to control the suction power of the cleaner.
MAINTENANCE
Emptying the dust compartment subassembly
- Always operate the cleaner with the dust compartment subassembly whole installed.
- If you forget to attach HEPA and filter or attach them in the wrong manner, the dust compartment subassembly may not rinse.
After removing the flexible tube, hold handle and press the locking button.
Cleaning and changing filter, HEPA and sponge
- Filter and songe for air-inlet should be cleaned at least five a year or when it becomes visible solid.
- Clean HEPA for air-inlet when you find it is filled in.
- HEPA for air-inlet and filter for air-outlet are changeable.
- Always operate the cleaner with filters and sponge installed. Otherwise, reduced suction or motor damage may be result.
- Disconnect from electrical outlet, before cleaning filter.
- Do not use a washing machine to rinse filter.
- Do not use hair drier to dry it.
Cleaning and changing filter, HEPA and sponge for air-inlet
- After opening the dust-glass cap subassembly, press the lock block of dust cup cover until it is unlocked
- Remove the seal ring of HEPA
- Remove HEPA from the bracket.
- Rinse bracket, filter and sponge in lukewarm water and dry them completely (Sponge and HEPA is rinsed by brush.)
- Put them back.
Changing filter for air-outlet
- Open the grille for air outlet.
- When open the grille for air outlet, the filter for air outlet is found.
- Take the filter out and change a clean one.
- Close the grille for air outlet.
TECHNICAL SPECIFICATION
- Voltage: AC 220V-240V~
- Frequency: 50Hz/60Hz
- Power: 2200W
Correct Disposal of this product:
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased, they can take this product for environmentally safe recycling.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>