KLARSTEIN 10032894 Vapoair Onyx Ultrasonic Humidifier Instruction Manual
- June 5, 2024
- Klarstein
Table of Contents
VAPOAIR ONYX
Ultrasonic Humidifier
10032894
Dear Customer,
Congratulations on purchasing this equipment. Please read this manual
carefully and take care of the following hints to avoid damages. Any failure
caused by ignoring the items and cautions mentioned in the instruction manual
is not covered by our warranty and any liability. Scan the QR code to get
access to the latest user mannual and other information about the product
TECHNICAL DATA
Item Number | 10032894 |
---|---|
Power supply | 220-240 V ~ 50/60 Hz |
Power | 110 W |
Water tank capacity | 5,5 L |
Evaporation Rate | ≥ 350 ml/hour |
SAFETY INSTRUCTIONS
- Children over 8 years of age, mentally and physically handicapped persons may only use the device if they have been familiarized in detail with the functions and safety precautions by a supervisor responsible for them. Do not allow children to play with the device. Children from 8 years of age may only clean the device under supervision.
- Check the voltage on the device plate before use. Only connect the device to sockets that correspond to the voltage of the device.
- Place the unit on a stable, level surface. Do not place the redness in direct sunlight or near heat sources such as ovens or radiators. Doing so may cause the unit to malfunction.
- Do not touch the plug with wet hands.
- If the power cord or plug is damaged, it must be replaced by the manufacturer, an authorized service center or a similarly qualified person.
- Do not open the housing. The device contains parts that are not accessible to the user. Repairs may only be carried out by qualified specialists.
- Fill the tank with fresh, distilled or demineralized water. Do not switch on the unit if there is no water in the tank.
- Do not shake or tilt the unit. Otherwise, the water from the tank may overflow and penetrate inside the unit.
- If water drips on the unit or penetrates into the unit, immediately unplug the unit and contact a specialist dealer.
- Never touch the water or components while the unit is running.
- If there is an unusual smell, turn the unit off, unplug it and have it checked by a specialist dealer.
- Do not pour water warmer than 40 °C into the tank.
- Disconnect the plug before cleaning the unit or removing the tank.
- Never immerse the device and the power cord in water or other liquids.
- The unit must be cleaned regularly. Please observe the cleaning instructions in this manual.
- If you are not going to use the unit for a long time, unplug it.
- Never use this device in rooms where sprays are used or where oxygen is administered.
- Do not place clothes or towels on the machine.
- When you move the unit, lift it at the base and not at the water tank.
- The humidifier is intended for indoor and domestic use only.
Note: Do not use the humidifier if the air in the room is already sufficiently humid (relative humidity of at least 50%). The ideal relative humidity is between 45% and 60%. Excess moisture can be seen in the form of condensation on cold surfaces or cold walls in the room. To measure humidity correctly, use a hygrometer that is available in specialist shops and DIY stores.
PRODUCT OVERVIEW
OPERATION AND MODES
Before first Use
- For first Operation, put unit in the room temperature for half of an hour before running.
- Use clear water not over 40 degree C
- Check the water basin, make sure it is clear.
Getting Started
- Put the machine on a flat surface.
- When you take out of the water tank, you must be turn on the child safety lock
- Fill the water into the water tank, and then tighten the tank cover.
- Put the water tank on the main base, and turn off the child safety lock.
- Plug into the socket. The display will be on and show current temperature. After 30 seconds, it switches into current humidity. Temperature and humidity will switch every 30 seconds. If without any operation for 15 seconds, LED light will become dark. Press any button, LED be bright and enter related function.
How to insert the remote control batteries
(The batteries are not included in the scope of delivery.)
- Flip the remote on its side.
- Press the battery release on the bottom edge of the remote.
- Grasp the battery socket and pull the battery out.
- Insert a lithium battery type CR2025.
AUTO Mode and Mist Speedt
Touch the POWER button .
- If lack of water, display will show and current temperature or humidity.
- If there is enough water, display will show [AUTO] and current temperature or humidity, and water tank light will be on.
Device works in AUTO mode. (If it shows humidity before turn off, it will show
humidity when turn on again. But it will switch into temperature after 5
seconds, and switch back to humidity after 30 seconds.) Touch POWER button
again to turn off the device.
Touch the AUTO button to out of AUTO mode and the mist start from first speed
until fourth speed for each touch. Touch the fifth times, it enters AUTO mode.
In Auto mode, the device determines the optimal humidity by the formula and
starts to achieve. When the current humidity less than the table showed
humidity, it is in the third speed operation. When the humidity arrived, the
machine will be in the first speed operation. The device checks the accordance
of the temperature level and the humidity level every 1 minute.
Air temperature in °C | Humidity in % |
---|---|
≤ 18 | 65 |
19-20 | 60 |
21-22 | 55 |
23-24 | 50 |
25-26 | 45 |
≥ 27 | 40 |
ION Mode
Touch ION button to turn on the anion generator. It shows the symbol on LED
display. Touch again to stop the function. Long press this button for 3
seconds to turn on/off water tank light. ION button is not available when lack
of water.
Heat Mode
Touch HEATING button , the warm mist will come out after 10~15 minutes. It
shows the symbol on LED display. Touch again to stop the function. Mist will
become cool after 5~10 minutes.
Constant Humidity Mode
Touch CONSTANT HUMIDITY button , you may set the humidity arranged from 40% to
75%. Press once, it will increase by 5%. After setting expected humidity, LED
display blinks for 5 seconds, then switch to show current temperature. If
current humidity is lower than setting humidity, device will work in the third
speed. If current humidity is higher than setting humidity, device will stop
humidifying and stay in sleeping state.
Note: During sleep state, ION and HEATING function are not available to
select.
When current humidity is lower than setting humidity 2%, device will exit
sleeping state and humidify in previous state. When setting reaches 75%, press
again, it will turn into
AUTO mode and show “CO” on LED display. Press again, it will be back to 40%.
Note: AUTO button is not available to select under CONSTANT HUMIDITY
function is on!
Timer Mode
Touch the TIMER button , the LED display will show the timer [1H]. There are
12 timer setting: 1,2,3,4,5,6,7,8,9,10,11,12 hours. The timer shows the rest
operation time and decreases by 1 hours. After setting, if the timer is set at
12 hours, LED display shows [11] after one hour. This function is still
available when lack of water.
Low Water Alarm
Once the water in the basin is too little to keep the machine working, device
will automatically stop working and warn by three beeps. LED shows . Refill
the water, and the machine will restart.
RELATIVE HUMIDITY
The percentage of water mist in a given space with a given air temperature is
named as relative humidity, i.e. 45%. The air contains water mist more or
less. The proportion of water mist to the air varies according to different
air temperatures. The higher the temperature, the more water mist inhaled in
the air.
In the winter, the cold air outside enters the room and becomes warmer by the
higher temperature in the room. As a result, the relative humidity decreases.
If you want to keep the healthy environmental humidity, we need to increase
the mist volume in the air. The humidifier can do that for us. Relative
humidity in different environments suitable for people:
- Bedroom, living room: 45-65%
- Patient’s room: 40-55%
- Room with computer, experiment equipment: 45-60%
- Room with piano: 40-60%
- Museum, exhibition hall, and library: 40-60%
CLEANING AND CARE
Note: Always switch off and unplug the unit before cleaning.
- Use cold boiled water or distilled water.
- Clean the transducer, water tank and basin unit every week.
- Change the water in water tank more often to keep it fresh.
- Make sure to pull out the water from the water tank and dry the water basin before you store the unit unused for a long period of time.
- Clean the whole unit and make sure that all parts of the unit are dried completely before unused for longer period of time.
How to clean the transducer:
- Put 5-10 drops of cleaning abluent on the surface of the transducer, wait for 2-5 minutes.
- Brush off the scale from the surface.
- Rinse the transducer with clean water.
- Never use sharp or solid objects for cleaning the transducer
How to clean the Basin unit:
- Clean the water basin with soft cloth .if there is excess film on the surfaces, then soak the cloth with vinegar and repeat the process.
- If there is a film in any of the depressions along the basin ,drop a bit of vinegar into depression and clean it out with a brush.
- Rinse the water basin with clean water.
How to clean the Ceramic Filter System:
- Clean and activate the ceramic balls after use of 1000 L water regularly.
- Remove the filter from the tank cover.
- Put some white vinegar into a glass, soak the filter in the vinegar for about 10 minutes.
- Remove the filter from the glass and shake it several times.
- Clean and rinse the filter once again with fresh water.
If you don’t plan to use the humidifier for a long time, remove the filter from the water tank and let it dry thoroughly, then wrap it in protective packaging and keep it next to the humidifier in a cool, dry and dark storage space.
Storage
- If you are not going to use the humidifier for a long time, make sure that all its parts are dry, including the operating chamber of the sprayer.
- Do not store the unit with water in the water tank and in the operating chamber of the sprayer.
- Clean and dry the filter-cartridge before taking it away for storage. Keep the filtercartridge in a cool darkened place.
- Keep the humidifier away from children in a dry cool place.
TROUBLESHOOTING
Problem | Possible Cause | Suggested Solution |
---|---|---|
Power lamp off or does not work | Humidifier is not plugged into the power | |
outlet or loose. | Connect power cord to electrical outlet and press power |
button
Power lamp is on but no mist| No water in water tank| Fill water into water
tank
The mist has a strange odour| A New unit| Take out water tank, open cover, let
it stay 12 hours
in cool position
It either has dirty water or the water has been stagnant too long| Clean water
tank, fill with clear water
Power light is on, but the machine doesn’t work.| Too much water in the water
basin| Remove the water tank.
Take a small cup and remove some of the water from the machine’s water basin.
Reinsert the water tank and make sure that it sits properly
The volume of spray mist is too low| Too much mineral scale in the water
basin| Clean transducer
Water is too dirty or water kept too long in the tank| Clean water tank and
refill with clean water
Abnormal noise| Vibration in the water tank because the water level too low|
Fill the water tank
Machine is on and unstable surface| Move the unit to a stable flat surface
Spray mist is coming out of the area around the jets.| There are gaps between
the nozzle and water tank| Dip the nozzle in water for a while, clean it with
a damp cloth and put it back to the tank.
The following is not considered faulty operation:
- If your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a malfunction. The solution would be to clean the filter more often or use softer water.
- If you stand very close to the humidifier, you will hear the gurgling sound of water, this is normal.
- The machine operate very quietly but it is not completely silent. Noise levels less than 35 dB is considered normal.
DISPOSAL CONSIDERATIONS
If there is a legal regulation for the disposal of electrical and electronic
devices in your country, this symbol on the product or on the packaging
indicates that this product must not be disposed of with household waste.
Instead, it must be taken to a collection point for the recycling of
electrical and electronic equipment. By disposing of it in accordance with the
rules, you are protecting the environment and the health of your fellow human
beings from negative consequences. For information about the recycling and
disposal of this product, please contact your local authority or your
household waste disposal service.
This product contains batteries. If there is a legal regulation for the
disposal of batteries in your country, the batteries must not be disposed of
with household waste. Find out about local regulations for disposing of
batteries. By disposing of them in accordance with the rules, you are
protecting the environment and the health of your fellow human beings from
negative consequences.
MANUFACTURER & IMPORTER (UK)
Manufacturer:
Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany.
Importer for Great Britain:
Chal-Tec UK limited
Unit 6 Riverside Business Centre
Brighton Road
Shoreham-by-Sea
BN43 6RE
United Kingdom
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>